This Presolicitation opportunity from Department Of Veterans Affairs was posted on November 19, 2025. The submission period has ended. Browse the details below for market research, or find similar active opportunities.

C1DA--657A5-26-103, Renovate Building 42 - Specialty Care Clinic (Old Lab Area), (VA-26-00017944)

Awarded
36C25526R0029Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

Active Opportunities Like This One

NAICS: 541310
New
SLED
Master Planning, Design, And Construction Support Services For The West Sacramento Fire Training Facility
Solicitation # 26-073-RFP
The City of West Sacramento is soliciting professional architectural and engineering services for the master planning, design, and construction support of a new Fire Training Facility located within the Port of West Sacramento. The project is divided into two primary objectives: the creation of a comprehensive long-term master plan for the training campus and the implementation of Phase 1, which involves the design and construction of a permanent training building and associated site improvements. Key deliverables include operational plans to ensure training continuity during construction and the delivery of editable CAD files compatible with City standards. The selected consultant must implement a rigorous Quality Assurance and Quality Control program with specific review milestones from conceptual design through final construction documents. The selection process utilizes a points-based evaluation focusing on firm qualifications and key personnel (20%), project understanding and relevant experience (20%), cost-effectiveness (10%), and proposal completeness (5%). Proposals must be submitted via the City's e-Procurement Portal by January 8, 2027, and are limited to 25 pages. The contract incorporates various federal requirements, including the Byrd Anti-Lobbying Amendment and the Contract Work Hours and Safety Standards Act for awards exceeding $100,000, and requires adherence to ADA compliance and prevailing wage rates. The agreement allows for two optional one-year extensions and requires a unique entity identifier for contracts over $25,000 or those funded by federal dollars.
Capital Projects - Construction

POSTED

about 10 hours ago

DEADLINE

in about 2 months
NAICS: 541310
New
Federal
Update Dublin VA Life Safety Drawings
Solicitation # 36C24727Q0096_1
The Department of Veterans Affairs is soliciting professional architectural, fire protection engineering, life safety, and code consulting services to update the Statement of Conditions (SOC) drawings for the Carl Vinson VA Medical Center in Dublin, Georgia. The selected contractor will be responsible for conducting assessments based on NFPA 101 and other relevant NFPA codes, including NFPA 1, 3, 4, 10, 13, 14, and 17A. Key deliverables include life safety plans provided in PDF and AutoCAD formats, a detailed survey report on fire and life safety features, an Excel spreadsheet of all findings, and meeting minutes submitted within two business days of each session. The project is scheduled for a 150-day period of performance from December 31, 2026, to May 30, 2027, with work performed during normal business hours. This procurement is a total set-aside for Certified Service-Disabled Veteran-Owned Small Businesses (SDVOSB). Awards will be made using the Lowest Priced Technically Acceptable (LPTA) process, evaluating offers based on technical adherence to the Statement of Work, past performance via FAPIIS ratings, and price. The contractor must comply with Joint Commission and VA requirements, protect sensitive VA information and Controlled Unclassified Information, and submit payment requests electronically. The government retains the right to inspect all deliverables and may require the remediation of nonconforming services at no additional cost to the government.
247-NETWORK Contract Office 7 (36C247)

POSTED

about 13 hours ago

DEADLINE

in 7 days

AI Contract Overview

Show more

Solicitation 36C25526R0029 is a pre-solicitation notice for Architectural and Engineering (A-E) services to renovate a 4,700-square-foot area of Building 42 at the Marion VAMC. The project involves converting a former laboratory into a modern Cardiology Examination Clinic, Stress Testing Clinic, and Device Clinic, featuring eleven patient care spaces and necessary support areas. The estimated magnitude of the resulting construction project is 4,855,650 dollars. The selected A-E firm will be responsible for full design development, including MEP, architectural, IT, fire protection, and physical security systems, as well as providing construction period services. Key deliverables include design submissions at 15, 30, 60, 90, and 100 percent completion, a VPIH survey for hazardous materials, and the integration of deductive bid alternates allowing for up to a 20 percent cost reduction. This procurement is 100 percent set aside for Service-Disabled Veteran-Owned Small Businesses (SDVOSB) and is conducted in accordance with the Brooks Act and FAR Subpart 36. Qualified firms must submit a PDF version of Standard Form 330, not exceeding 50 pages or 10 MB, by 3:00 PM Central on December 10, 2025. Evaluation is based on professional qualifications, specialized medical renovation experience, past performance, and geographic proximity, with a preference for firms within 450 miles of the facility. The most highly rated firm will be required to conduct a site visit before submitting a price proposal. A Firm-Fixed-Price contract is anticipated, with an award date expected no later than February 23, 2026, contingent upon funding.

General Info

Contract Value

$666,910.29

NAICS

541310 - Architectural Services

Place of Performance

KS, USA

Set-Aside

SDVOSBC

Award Issued Date

Potential End Date

October 17, 2031

Documents

1
DOCX, High priority: read this first14 pages · presolicitation
High

Read the document

Every page of every file, in your free workspace.

Read the document

AI Contract Breakdown

Uniform Contract Format

Sign up to view the full breakdown with detailed analysis of each section.

View Full Breakdown

This one is closed. Find the next one like it.

Open contracts like this one, right now:

  • Planning & Architectural ServicesOpen now, due in 21 days
  • Right-of-Way Appraisal ServicesOpen now, due in 21 days
See open contracts like this

Ask CLEATUS

I've read this contract. Ask me anything.

Timeline

PhaseAwarded
Posted

Presolicitation

Awarded

Contract was awarded

Submission Closed

Find active opportunities like this

Get full access to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyDepartment Of Veterans Affairs → 255-NETWORK Contract Office 15 (36C255)
Contacts1 person available
OfficeLEAVENWORTH, KS, 66048, USA

Full Description

Show more
Pre-Solicitation Notice: Request for Architectural and Engineer 330 submission Solicitation: 36C25526R0029, Renovate Building 42 - Specialty Care Clinic (Old Lab Area), Project No. 657A5-26-103.
CONTRACT INFORMATION
This A-E Services requirement is being procured in accordance with the Brooks Act (Public Law (PL0582) and implemented in accordance with the Federal Acquisition Regulation (FAR) Subpart 36. Firms will be selected for negotiation based on demonstrated competence and qualifications for the required work.
This procurement is restricted to Service-Disabled Veteran Owned Small Business (SDVOSB) firms. This requirement is being procured in accordance with the VAAM M836.6 implemented in FAR Subpart 36.6.
This is not a Request for Proposal, and an award will not be made with this announcement. This announcement is a request for SF 330 s from qualified Architectural and Engineer (A&E) contractors that meet the professional requirements.
The selection criteria for this acquisition will be in accordance with FAR 36.602-1, evaluation factors are listed below. The completed SF 330 will be evaluated by the Marion VAMC Evaluation Board in accordance with FAR 36.602-5(a) and the selection report shall serve as the final selection list, which will be provided directly to the Contracting Officer. Negotiations will be conducted beginning with the most highly qualified firm. The Government will not pay nor reimburse any costs associated with responding to this request. The Government is under no obligation to award a contract as a result of this announcement.
The most highly rated firm must physically come to the site and review the project before submitting a price proposal and letter of understanding at no cost to the government. The contract is anticipated to be awarded no later than February 23, 2026. Award of any resultant contract is contingent upon the availability of funds.
Personal visits to discuss this announcement will not be allowed.
The NAICS Code for this procurement is 541310, Architectural Services and the small business size standard of $12.5 Million. Award of a Firm Fixed Price contract is anticipated and award time for completion of design of this project is approximately 180 calendar days including time for VA reviews. The A/E firm shall also be required to perform construction period services if award of a construction project contract is made.
DATABASE REGISTRATION INFORMATION: Verification of status of apparently successful offeror this acquisition is 100% set-aside for qualified service-disabled veteran owned small business A/E firm s incompliance with VAAR 852.219-73. Only businesses listed as certified in the SBA certification database at https://veterans.certify.sba.gov/, shall be considered.
SYSTEM FOR AWARD MANAGEMENT (SAM.GOV): Federal Acquisition Registrations require that federal contractors register in the System for Award Management (SAM.GOV) database at https://sam.gov/content/ and enter all mandatory information into the system. Award cannot be made until the contractor has registered. Offerors are encouraged to ensure that they are registered in SAM.GOV prior to submitting their qualifications package.
THE EXCLUDED PARTIES LIST SYSTEM (EPLS): To ensure that the individuals providing services under the contract have not engaged in fraud or abuse regarding Sections 1128 and1128A of the Social Security Act regarding federal health care programs, the contractor is required to check the Excluded Parties List System (EPLS) located at https://sam.gov/content/ for each person providing services under this contract. Further the contractor is required to certify that all persons listed in the qualifications package have been compared against the EPLS list and are NOT listed. During the performance of this contract the Contractor is prohibited from using any individual or business listed on the List of Excluded Individuals/Entities.
E-VERIFY SYSTEM: Companies awarded a contract with the federal government shall be required to enroll in E-Verify within 30 days of the contract award date. They shall also need to begin using the E-Verify system to confirm that all their new hires and their employees directly working on federal contracts are authorized to legally work in the United States. E-Verify is an Internet-based system that allows an employer, using information reported on an employee's Form I-9, to determine the eligibility of that employee to work in the United States. There is no charge to employers to use E-Verify. (FAR 52.222-54)
Qualified A-E firms are required to respond if interested by submitting one (1) original completed Standard Form 330 qualification package Parts I and II to include all consultants (form available on-line at: http://www.gsa.gov/portal/forms/download/116486).  Must include in Part I Section H an organizational chart of the firm (excludes consultants) and a design quality management plan. Submission information incorporated by reference is not allowed. All submissions must be in pdf format and emailed. Email subject line shall clearly identify Solicitation number: 36C25526R0029 and project name, Renovate Building 42 - Specialty Care Clinic (Old Lab Area), Project No. 657A5-26-103. Responses must be received by 3:00 PM Central on December 10, 2025 via e-mail to the Contracting Officer at Sign up to see this detail, and Contact Specialist Sign up to see this detail.
The 330 submissions must be a pdf document and must not exceed 10 MB.
The A/E Firm must provide Basic Professional Services as delineated in the Scope of Work. As part of the Basic Professional Services, Marion VAMC Engineering Service expects the following primary A/E disciplines to be included: Supervisory, VPIH, Civil/Structural, Architectural, Mechanical, Plumbing and Electrical, Physical Security and Fire Protection. Interested firms shall be required to respond to additional announcements separately from this announcement without further notice from the Government when posted to the Contract Opportunities website at https://sam.gov. The Contract Opportunities website is the only official site to obtain these documents. Additional information about this project will be issued on the System for Award Management website https://www.sam.gov/content/opportunities once available.
PROJECT INFORMATION
This project will Renovate a 4,700-square-foot section of Building 42, previously used for the facility s laboratory services, to accommodate a modern Cardiology Examination Clinic, Stress Testing Clinic, and Device Clinic.
EVALUATION FACTORS:
Selection criteria are in accordance with Federal Acquisition Regulation (FAR) Part 36.602-1 and VAAM 836.602-1. Prospective firms are required to address all selection criteria within submitted SF330 packages using additional pages as necessary.  SF 330 submissions including any additional pages are not to exceed fifty (50) pages. Each page cannot exceed 81/2 x 11 in size. Prospective firms are required to address all selection criteria within submitted SF330 packages using additional pages as required and SF 330 submissions including any additional pages are not to exceed fifty (50) pages. SF 330 must be submitted as a PDF and cannot exceed 10MB.
Qualifications (SF330) submitted by each firm for Project No. 657A5-26-103, Renovate Building 42 - Specialty Care Clinic (Old Lab Area) will be reviewed and evaluated based on the following evaluation criteria listed below: Evaluation Criteria: Professional Qualifications: the qualifications of the individuals will be examined for experience and education and their record of working together as a team that are necessary for satisfactory performance of required services. The architectural firm capable of preparing all design and construction documentation including, but not limited to advance planning, design, and construction oversite (including final as-built drawings) at the VA Medical Center in Marion, Illinois. A-E s on staff representing the project or signing drawings in each discipline must be licensed to practice in one of the US States. Provide Professional License numbers and/or proof of licensure. The team shall have demonstrable expertise in their respective fields: Architect, Structural Engineer, Mechanical Engineer, Fire Protection Engineer, Life Safety Engineer, Plumbing Engineer, Communication (voice & data), Electrical Engineer, and Cost Estimator with experience on projects of similar size and complexity.
Specialized Experience and Technical Competence: specific experience and technical skill in the type of work required for this project, including medical renovations to existing medical facilities, experience in energy conservation, pollution prevention, waste reduction, and the use of recovered materials, VA safety and physical security design, experience in abatement of hazardous construction materials, energy conservation, pollution prevention, waste reduction and the use of recovered materials. Experience and qualification of personnel proposed for assignment and their record of working together as a team. The effectiveness of proposed project team (including management structure, coordination of disciplines, subcontractors, and prior working relationships) will be examined. The qualifications for Architect shall include a summary of at least five similar projects that demonstrate technical capabilities and how well the proposal addresses technical capabilities in design quality management procedures, Computer-Aided Design and Drafting/Building Information Modeling, equipment resources, and laboratory requirements for the firm.
Capacity to Accomplish the Work: The prime contractor will be evaluated to determine if it has the general workload and staffing capacity within its design office which will be responsible for the design to accomplish the work in the required time. In accordance with VAAR 852.219-75 :  In the case of a contract for services (except construction), the contractor will not pay more than 50% of the amount paid by the government to it to firms that are not certified SDVOSBs listed in the SBA certification database as set forth in 852.219-73 or certified VOSBs listed in the SBA certification database as set forth in 852.219-74. Any work that a similarly situated certified SDVOSB/VOSB subcontractor further subcontracts will count towards the 50% subcontract amount that cannot be exceeded. Other direct costs may be excluded to the extent they are not the principal purpose of the acquisition and small business concerns do not provide the service as set forth in 13 CFR 125.6. Prime contractor must include its certification of compliance with the limitations on subcontracting specified in 852.219-75 with its 330 submissions. 
Past Performance: The past performance of projects that are complete (design and construction) that the firm has designed relevant in scope to the advertised project that were accomplished with the Department of Veterans Affairs, other Government agencies, and private industry in terms of cost control, quality of work, and compliance with performance schedules will be examined. Project past performances that are older than 5 years will receive a lesser rating than those references for projects accomplished within the past 5 years. Projects that are submitted and not constructed will not be considered.
Location of Design Firm: Knowledge of the locality of the project and the geographic proximity of each firm to the location of the VA Medical Center will be evaluated. The mileage consideration is in compliance with FAR 36.602-1. This factor will apply to the office from which the prime contractor s business office is established. Firms within 450 miles of the medical center will receive a more favorable rating than those more than 450 miles away. Firms may use Google Maps, MapQuest, Yahoo Maps, or Rand McNally to determine and report the distance of the office where the Prime Contractor is established.  Prime contractor shall not use a subcontractor office, consultant office, or any office other than Prime Contractor s physical location established prior to publication of this notice to determine distance to the Marion VA. 
Reputation in A/E Community: Reputation and standing of the firm and its principal officers within the design community with respect to professional performance, general management and cooperativeness, including awards, merits and recommendations.
Claims and Terminations: Record of significant claims against the firm because of improper or incomplete architectural and engineering services.
The extent to which potential contractors identify and commit to the use of service-disabled Veteran-owned small businesses (IAW VAAM M836.602-1).
Experience in construction period services to include professional field inspections during the construction period, review of construction submittals, support in answering requests for information during the construction period, and support of construction contract changes to include drafting statements of work, and cost estimates shall be included as an evaluation criterion when construction period services is included in the statement of work for A-E services (IAW VAAM M836.602-1).
852.219-75 VA Notice of Limitations on Subcontracting - Certificate of Compliance for Services and Construction. As prescribed in 819.7011(b), insert the following clause: VA Notice of Limitations on Subcontracting - Certificate of Compliance for Services and Construction (NOV 2022) (a) Pursuant to 38 U.S.C. 8127(k)(2), the offeror certifies that - (1) If awarded a contract (see FAR 2.101 definition), it will comply with the limitations on subcontracting requirement as provided in the solicitation and the resultant contract, as follows: [Contracting Officer check the appropriate box below based on the predominant NAICS code assigned to the instant acquisition as set forth in FAR 19.102.] (i) X  Services. In the case of a contract for services (except construction), the contractor will not pay more than 50% of the amount paid by the government to it to firms that are not VIP-listed SDVOSBs as set forth in 852.219-73 or VOSBs as set forth in 852.219-74. Any work that a similarly situated VIP-listed subcontractor further subcontracts will count towards the 50% subcontract amount that cannot be exceeded. Other direct costs may be excluded to the extent they are not the principal purpose of the acquisition and small business concerns do not provide the service as set forth in 13 CFR 125.6. (ii)  General construction. In the case of a contract for general construction, the contractor will not pay more than 85% of the amount paid by the government to it to firms that are not VIP-listed SDVOSBs as set forth in 852.219-73or VOSBs as set forth in 852.219-74. Any work that a similarly situated VIP-listed subcontractor further subcontracts will count towards the 85% subcontract amount that cannot be exceeded. Cost of materials are excluded and not considered to be subcontracted. (iii)  Special trade construction contractors. In the case of a contract for special trade contractors, the contractor will not pay more than 75% of the amount paid by the government to it to firms that are not VIP-listed SDVOSBs as set forth in 852.219-73 or VOSBs as set forth in 852.219-74. Any work that a similarly situated subcontractor further subcontracts will count towards the 75% subcontract amount that cannot be exceeded. Cost of materials are excluded and not considered to be subcontracted. (2) The offeror acknowledges that this certification concerns a matter within the jurisdiction of an Agency of the United States. The offeror further acknowledges that this certification is subject to Title 18, United States Code, Section 1001, and, as such, a false, fictitious, or fraudulent certification may render the offeror subject to criminal, civil, or administrative penalties, including prosecution. (3) If VA determines that an SDVOSB/VOSB awarded a contract pursuant to 38 U.S.C. 8127 did not act in good faith, such SDVOSB/VOSB shall be subject to any or all of the following: (i) Referral to the VA Suspension and Debarment Committee; (ii) A fine under section 16(g)(1) of the Small Business Act (15 U.S.C. 645(g)(1)); and (iii) Prosecution for violating section 1001 of title 18. (b) The offeror represents and understands that by submission of its offer and award of a contract it may be required to provide copies of documents or records to VA that VA may review to determine whether the offeror complied with the limitations on subcontracting requirement specified in the contract. Contracting officers may, at their discretion, require the contractor to demonstrate its compliance with the limitations on subcontracting at any time during performance and upon completion of a contract if the information regarding such compliance is not already available to the contracting officer. Evidence of compliance includes, but is not limited to, invoices, copies of subcontracts, or a list of the value of tasks performed. (c) The offeror further agrees to cooperate fully and make available any documents or records as may be required to enable VA to determine compliance with the limitations on subcontracting requirement. The offeror understands that failure to provide documents as requested by VA may result in remedial action as the Government deems appropriate. (d) Offeror completed certification/fill-in required. The formal certification must be completed, signed and returned with the offeror's bid, quotation, or proposal. The Government will not consider offers for award from offerors that do not provide the certification, and all such responses will be deemed ineligible for evaluation and award. Certification I hereby certify that if awarded the contract, [insert name of offeror] will comply with the limitations on subcontracting specified in this clause and in the resultant contract. I further certify that I am authorized to execute this certification on behalf of [insert name of offeror]. Printed Name of Signee: Printed Title of Signee: Signature: Date: Company Name and Address: A.1 SCOPE OF WORK
Magnitude of Construction Project to be designed: $4,855,650. The A/E will also be required to incorporate deductive alternate bid items into the construction documents that will allow for up to a 20% cost reduction. SCOPE OF CONSTRUCTION PROJECT: 1. Existing Conditions: The 4,700-square-foot area of Building 42 designated for reassignment and renovation previously housed the facility s laboratory and was subdivided to support efficient workflows for that function. Building 42 was constructed in the mid-1990s to accommodate outpatient services, emergency care, imaging, pharmacy, laboratory diagnostics, and specialty care. It is a single-story structure featuring a basement with piping infrastructure and an access tunnel.
2. Project Intent: a. Survey/Site Investigation: i. A survey/investigation shall be undertaken to fully assess site conditions and existing conditions of the proposed project area. ii. Investigation into other potential system upgrades will occur concurrently. Upgrades could be driven by advances in technology, safety, energy savings or any other factors which would improve overall system performance within the limitations of the project intent. iii. Investigation shall include documenting station utilities that may be affected during construction activity. These may be interior or exterior, above or below grade relative to the facility.
b. General Conditions: i. The A/E shall investigate the impact of infection control and maintaining hospital mitigation of air quality requirements, vibration and noise pollution. ii. The contractor will be responsible for field verification of existing utilities related to this project s requirements. If any utilities are damaged during construction activity all mitigative repairs shall be the responsibility of the contractor. iii. VA Engineering Service personnel will assist when site inspection procedures affect the operations of any of the building utility systems. iv. All utilities are critical to facility operations. Any investigation or work impacting the facility or requiring a shutdown shall be scheduled twenty one (21) days in advance with written notice. Work shall be performed at nights and on weekends. The COR has the right to stop work after 8 hours of planned medical facility outages. v. All proposed rework as well as the final, as-built conditions of the building shall be subject to comment, revision and approval by the Illinois State Historic Preservation Agency. All costs and labor incurred to achieve a design approved by the Historic Preservation Agency shall be the responsibility of the A/E. vi. Design errors or omissions, which result in damages or additional cost to the Governement will be evaluated for potential A/E liability. If the Government determines that the A/E is financially liable for a design deficiency, the Government will advise the A/E by official correspondence. The Department of Veterans Affairs, actively pursues reimbursement of costs incurred by the Government as result of the A/E s errors and/or negligent performance. The preferred method of settlement of A/E financial liability is for the A/E to negotiate directly with the Contractor and provide the result to the Department of Veterans Affairs for review and approval. Where the A/E cannot reach an agreement with the Construction Contractor or if the A/E declines to negotiate, The Department of Veterans Affairs will arrange settlement directly with the Contractor and will bill the A/E. vii. All equipment and finishes to be included in the project design shall be in accordance with current Marion VAMC standards and existing maintenance contracts. viii. The normal operating hours of this facility are 7 am to 4:30 pm, Monday through Friday, excluding recognized holidays. The construction documents shall require the contractor to reflect this in his proposed work schedule. Work outside the normal operating hours shall require prior authorization by the VAMC. c. Demolition: i. As determined during design, all existing materials removed during construction will be disposed of according to the direction of the construction documents and as directed by VA staff.
d. Industrial Hygiene: i. Provide an abatement plan for any hazardous materials (asbestos, lead, etc.) which are known prior to or discovered during the investigation and construction phases.
e. Structural: i. Determine capacity of existing building structure to accept the upgraded mechanical components proposed, if needed. ii. If weaknesses or inabilities to accept the components are encountered, modifications to the structure to allow for the upgraded component would likewise be proposed as part of the project documents. iii. Determine anchorage and bracing necessary to resist seismic loads for all material and components added by this project in accordance with the VA Structural Design Manual (PG-18-10). f. Architectural: i. The scope of architectural work shall include all work architectural work necessary to effectively update the spaces included in the project area.
g. Mechanical: i. The scope of mechanical work shall include updates to all existing mechanical systems that serve the proposed project area. ii. HVAC system capable of meeting most recent VA HVAC design requirements for 100% outside air in patient care spaces. h. Plumbing: i. The scope of plumbing work shall include updates to all plumbing systems, fixtures, outlets, disposal and ventilation systems, including: i. Domestic water systems piping, fixtures, etc. ii. Medical gas systems including piping, valves, outlets, panels, etc. iii. Fire Protection systems iv. Waste water disposal/sanitary sewer
i. Electrical/IT/Telecom: i. The scope of electrical/IT/telecom work shall include updates to all existing electrical/IT/telecom systems that serve the proposed project area. ii. Provide construction period services for arc flash and protective device coordination. After new equipment selection, the A/E shall provide the aforementioned services in addition to typical design phase site investigation and construction phase site visits. Submit TCC s to the COR for approval. Refer to the VA Electrical Design Manual (PG-18-10) section 1.10. Include VA Master Spec (PG- 18-1) 26 05 73. iii. Provide a design that coincides with the Facility Master Plan for future expansion and capacity. The infrastructure to support identified future loads shall not be constructed but planned in a manner that shows equipment and devices that support growth on plans.
j. Construction Phasing: i. Construction contract will utilize critical path phasing as necessary to minimize interruption and disturbance to the building and its occupants. ii. Phasing shall be determined through collaborative effort of both the A/E firm and the VAMC Engineering Service. III. SCOPE OF WORK FOR A/E: 1. Design Development: a. The A/E shall make investigations necessary to thoroughly evaluate the area. All designs shall be in accordance with A/E Submission Instructions for Minor and NRM Construction Program, Program Guide PG-18-15, Volume C. b. Upon completion of initial field survey and assessment, provide a comprehensive report of existing conditions and findings to Marion VAMC Engineering Service. Report will include initial cost estimate for all work included in the Renovate Building 42 Specialty Care Clinic (Cardiology). This report will be considered the Design Narrative as referenced in B5 DESIGN REVIEW AND COMPLETION SCHEDULE below.
c. Design shall comply with the most current version of the VA Physical Security & Resiliency Design Manual at time of award found on the VA technical Information Library: https://www.cfm.va.gov/til/dManual.asp
d. General Statement: The A/E shall prepare plans and specifications for a construction contract to accomplish the following work:
I. Renovate a 4,700-square-foot section of Building 42, previously used for the facility s laboratory services, to accommodate a modern Cardiology Examination Clinic, Stress Testing Clinic, and Device Clinic. II. Provide a design to include eleven (11) patient care spaces, including: eight (8) patient exam rooms for Cardiology outpatient care, two (2) echocardiogram equipped exam rooms directly adjacent to the stress lab, and one (1) patient consultation space for the device clinic. III. Provide a design to accommodate all required ancillary /support spaces as outlined in the latest VA Cardiovascular Laboratory Service Design Guide. IV. Provide a design to update all systems within renovation area, including but not limited to: i. Mechanical, Electrical, Plumbing (MEP) ii. Architectural iii. Information Technology (IT) iv. Fire Protection v. Physical Security V. Provide a design that accommodates all the latest VA standards and code requirements for spaces intended for standard and intensive inpatient care. VI. Design to the Government s Guiding Principles for Sustainable Federal Buildings standards with verification by a Professional Engineering stamp and completion of the Guiding Principles Checklist. Architect is responsible for verifying that the construction meets the Guiding Principles for Sustainable Federal Buildings. VII. Full commissioning per the VA Whole Building Commissioning Process Manual as applicable to this building is required. All associated costs and labor (Commissioning agent(s), inspections/witnessing, and documentation) shall be the responsibility of the Architect. Provide cost estimates associated with deduct alternates. VIII. Design multiple deductive bid alternates into the construction documents equal to at least 20% of the total construction cost. The base design must be fully functional with or without the alternates. Provide an itemized cost estimate associated with each deduct alternate.
2. Construction Documents: a. After the VAMC approves the A/E's conceptual design, the A/E shall prepare construction documents necessary to accomplish the approved conceptual design. These documents shall bear the seals and signatures of all licensed individuals responsible for the content of the construction documents. Application of the seals and signatures shall be considered verification that the design was conducted in accordance with all applicable code requirements, standards and best engineering practices.
b. As part of the 100% design submission, the A/E shall provide a written synopsis describing the overall scope of the construction project as well as any pertinent information about the project that would assist potential bidders in preparing a comprehensive bid package. This synopsis is intended to be a general description of the project not to exceed two written pages in length. c. The final design documents from a resultant task order will be subject to review and approval (by signature) of all members of an Integrated Project Team (IPT) consisting of medical center personnel. These individuals will be identified by the COR at the first design review meeting.
3. Construction Period Service: The A/E shall perform construction period services as detailed later in this scope of work.
4. Functional Product: a. It is important to emphasize that the A/E shall perform design development and detailed design work, and prepare detailed construction documents, keeping in mind that the end result is a completely functional and fully operational system.
b. VPIH Survey: The A/E Firm will complete a survey, to include testing, identifying any and all asbestos and lead containing materials within the project area. This project will remove all lead and asbestos in areas being renovated.
c. All spaces within the scope of work must be designed according to applicable codes and standards. d. The A/E shall submit a design narrative (15%) and design plans (30%, 60%, 90%, 100% Contract Docs for Bidding, and Release for Construction Set) specifications, submittals schedule, estimates and other documentation in accordance with the B4 DESIGN DELIVERABLES section of this Supplement B. The construction work will be performed under a separate Firm-Fixed-Price contract awarded by the VA. As a result, the Construction Documents must conform to the estimated Total Construction Cost Price, not including any contingencies, and convey the entire construction work completely and clearly, such that any bidder can produce an accurate bid without surveying the work site.
e. The A/E will also participate in the Marion VAMC Pre-Construction Risk Assessment to determine the requirements for Infection Control, Interim Life Safety Measures, occupational safety and health, patient safety, public safety, security controls for physical and logistical access, and environmental controls and limitations on vibrations, noise, and disruptions to operations and utilities. The results of these assessments will be included in documentation submitted by the A/E pursuant to, and inclusive of, the Construction Documents.
f. Prior to submittal of a response to this proposal the A/E shall meet with the Contracting Officer s Representative (COR) at the proposed project site to review the scope of services and the project goals. The COR will provide A/E with a copy of the portions of the latest Facilities Condition Assessment (FCA) applicable to this project.
g. Overall site plans will be provided as a Reference Drawing with Buildings showing the areas within the project boundary.
h. The C&A requirements do not apply, and that a Security Accreditation Package is not required. 5. Sustainability Requirements: a. Design shall comply with the most current version of the VA Sustainable Design Manual at time of award found on the VA technical Information Library https://www.cfm.va.gov/til/sustain.asp
b. The following deviations are allowed: Not applicable.
c. GUIDING PRINCIPLES CHECKLIST: A/E shall complete and submit the appropriate Federal Energy Management Guiding Principles Checklist: https://energy.gov/eere/femp/downloads/guiding-principles-checklists-new-construction-and-modernization-and-existing END OF SCOPE OF WORK.

More opportunities from Department Of Veterans Affairs → 255-NETWORK Contract Office 15 (36C255)

Same awarding agency

NAICS: 238210
New
Federal
657A5-26-111, Triennial Electrical Testing
Solicitation # 36C25526R0186
Solicitation 36C25526R0186 is a fixed-price construction request for proposal issued by the Department of Veterans Affairs Network Contracting Office 15 for triennial electrical testing at the Marion VA Medical Center in Marion, Illinois. This project is a total set-aside for Service-Disabled Veteran Owned Small Businesses (SDVOSB) with an estimated magnitude between $500,000 and $1,000,000. The scope of work involves the maintenance, inspection, adjustment, testing, and calibration of the facility's Electrical Power Distribution System, specifically covering approximately 325 electrical panels, 135 medium and low voltage transformers, 220 switches, 6 generators, and 25 automatic transfer switches. All work must adhere to NETA 2019 standards, VHA Directive 1028, NFPA 99, NFPA 110, NFPA 70B, and the latest National Electrical Code. The contract will be awarded using the Lowest Price Technically Acceptable (LPTA) process, evaluating offerors on five technical factors: relevant past performance of the prime contractor, technical experience of the prime and electrical subcontractor, qualifications of key personnel, and the prime contractor's safety plan. To be acceptable, the prime contractor must demonstrate completion of two to three similar hospital electrical projects valued at $500,000 or more within the last five years. The period of performance is 150 calendar days, and the contractor is required to provide a four-week notice for any power outages. Key administrative requirements include the submission of bid, performance, and payment bonds, compliance with the Davis-Bacon Act and Buy American requirements, and the delivery of detailed maintenance and testing reports.
Electrical Contractors and Other Wiring Installation Contractors

POSTED

about 13 hours ago

DEADLINE

in 2 days
View Details
NAICS: 562910
New
Federal
J091--Aboveground Fuel Tank Inspection Services - Kansas City VAMC
Solicitation # 36C25527Q0047
The Department of Veterans Affairs, Network Contracting Office 15, is soliciting quotes for a five-year Indefinite Delivery/Indefinite Quantity (IDIQ) contract to provide annual inspection, maintenance, repair, certification, and fuel oil filtering services for sixteen aboveground storage tanks (ASTs) with capacities of 55 gallons or greater at the Kansas City VA Medical Center. This total SDVOSB set-aside procurement, under NAICS code 562910, supports the facility's Spill Prevention, Control and Countermeasure (SPCC) Plan Program. The period of performance runs from January 19, 2027, to January 18, 2032, with annual inspections required every February. Key deliverables include API 653-compliant certifications, interior and exterior tank inspections, hydrostatic or non-destructive integrity testing, and fuel polishing and recirculation. The contractor is responsible for all labor, materials, and equipment, including the capture, containment, transport, and disposal of all fuel, water, and filter waste using EPA-approved manifests. All work must adhere to API, ASTM, EPA, NFPA 110 Chapter 8, and OSHA 29 CFR 1910 standards. Personnel performing formal inspections must be certified by the Steel Tank Institute to SP001 or be API 653 certified with an STI SP001 adjunct certification. Award will be based on an equal evaluation of price, technical capability, and past performance. Required insurance includes general liability, pollution liability, and workers' compensation, with the Department of Veterans Affairs named as an additional insured.
Remediation Services

POSTED

about 13 hours ago

DEADLINE

in 24 days
View Details
NAICS: 541330
New
Federal
C222--589-27-108, Correct Electrical Deficiencies in Building 26 KCVA (ME) FY27 NRM VISN Base - AE (VA-27-00021035)
Solicitation # 36C25527Q0057_1
The Department of Veterans Affairs Network Contracting Office 15 is conducting a market survey for a Service-Disabled Veteran Owned Small Business (SDVOSB) to provide professional design services to correct electrical deficiencies in Building 26 at the Kansas City VA Medical Center. The scope of work involves addressing deficiencies in electrical closets, secondary distribution, uninterruptible power, and emergency power. The selected Architect/Engineer will be responsible for site visits, field investigations, and the preparation of narratives, studies, and design documents. Deliverables include design drawings, specifications, and Independent Government Cost Estimates (IGCE) submitted at 35 percent Schematic Design, 65 percent Design Development, 95 percent Construction Documents, and Final Bid Documents. All work must comply with Infection Control and Interim Life Safety Measures, and the period of performance for design work is 150 calendar days. This opportunity is a Sources Sought notice for market research purposes under NAICS code 541330, Engineering Services, with a size standard of 25.5 million dollars. Interested SDVOSB firms must be registered in SAM.gov and the SBA registry. To be considered, firms must submit a capability statement of no more than 10 pages by December 1, 2026, at 2:00 PM Central Time. This statement must include company contact information, Unique Entity ID, CVE certification, and evidence of comparable work performed within the last five years. In accordance with VAAR 852.219-75, the prime contractor must certify that no more than 50 percent of the government payment will be paid to firms that are not certified SDVOSBs.
Engineering Services

POSTED

about 13 hours ago

DEADLINE

in 14 days
View Details
NAICS: 236220
New
Federal
Z2DA--657-24-102JC - Prepare Site for New PET/CT, Room A011D (MD) FY27 NRM VISN Base, CON (VA-27-00017492) 657-27-1-8434-0001
Solicitation # 36C25527R0016
The Department of Veterans Affairs, Network Contracting Office 15, is seeking a construction contractor to prepare Room A011D at the John Cochran VA Medical Center in St. Louis, Missouri, for a new PET/CT installation. The scope of work includes general construction, alterations, mechanical and electrical work, utility systems, and the demolition and removal of existing structures. The contractor is responsible for providing all necessary supervision, tools, labor, materials, equipment, transportation, and testing. All work must adhere to project-specific drawings and specifications, VA TIL, and applicable local and national codes. The estimated cost magnitude for this project is between $1,000,000 and $2,000,000, with a performance period of 365 calendar days from the notice to proceed, which includes final inspection and clean-up. This procurement is set aside for Service-Disabled Veteran-Owned Small Businesses (SDVOSB) under NAICS code 236220, with a small business size standard of $45.0 million. To be eligible, contractors must be registered in the System for Award Management (SAM) and verified through the Small Business Administration registry. The successful prime contractor is required to perform at least 15 percent of the general construction labor. Award will be determined using the Best Value Lowest Price Technically Acceptable source selection process. Proposals are due by November 27, 2026, and all communications must reference project 657-24-102JC in the subject line.
Commercial and Institutional Building Construction

POSTED

1 day ago

DEADLINE

in 10 days
View Details
NAICS: 541330
New
Federal
C222--589-27-108, Correct Electrical Deficiencies in Building 26 KCVA (ME) FY27 NRM VISN Base - AE (VA-27-00021035)
Solicitation # 36C25527Q0057
The Department of Veterans Affairs Network Contracting Office 15 is conducting a market research survey for qualified Service-Disabled Veteran Owned Small Businesses (SDVOSB) to provide professional design services for Building 26 at the Kansas City VA Medical Center. The project focuses on correcting electrical deficiencies related to electrical closets, secondary distribution, uninterruptible power, and emergency power. The selected Architect/Engineer (A/E) will be responsible for a comprehensive design process including site visits, field investigations, and the preparation of narratives, studies, and construction documents. Deliverables must be submitted at specific milestones: 35% Schematic Design, 65% Design Development, 95% Construction Documents, and Final Bid Documents. The design must comply with Infection Control and Interim Life Safety Measures, and the A/E is required to verify existing conditions rather than relying solely on record drawings. The period of performance for all design work is 150 calendar days, including time for VA reviews. This opportunity is categorized under NAICS code 541330 for Engineering Services with a size standard of $25.5 million. In accordance with VAAR 852.219-75, the prime contractor must certify that no more than 50% of the government payment will be paid to firms that are not certified SDVOSBs. Interested firms must submit a capability statement of no more than 10 pages, including their Unique Entity ID, CVE certification, and evidence of comparable work performed within the past five years. Responses must be submitted via email to the contracting officer by December 1, 2026, at 2:00 PM Central Time.
Engineering Services

POSTED

1 day ago

DEADLINE

in about 1 month
View Details

Get AI-powered intelligence on the opportunities still open

Every solicitation package arrives shredded into a compliance breakdown and matched to your past performance, with incumbent history and alerts on amendments and award.

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS