Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, September 30 at 2:00 PM EDT

Register Free →

California Aqueduct Reach 2A Crimson Midstream Cathodic Protection Installation

Active
State & Local

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

General Info

Agency

California Water Resources, Department of

NAICS

237120 - Oil and Gas Pipeline and Related Structures ConstructionView NAICS

Place of Performance

Approximately 0.84 miles southwest of intersection of Orestimba Road and Aqueduct., CA

Set-Aside

NONE

Documents

(1)

Notice of Exemption for Crimson Midstream CP Installation

PDFnotice-of-exemption

AI Contract Breakdown

Uniform Contract Format

Sign up to view the full breakdown with detailed analysis of each section.

Timeline

Posted

forecast

Ready to pursue this opportunity?

Start your free trial to track this contract, build proposals with AI assistance, and manage your pipeline.

Organization & Contact Information

Show more
AgencyCalifornia Water Resources, Department of
Contacts1 person available
OfficeN/A
Organization / Agency
California Water Resources, Department of
Office AddressN/A
Contacts
Mark McDanielPlanner Scheduler/UC Supervisor

Full Description

Show more
Crimson Midstream requests encroachment permission to have its contractor, National Corrosion, install solar-powered cathodic protection (CP) equipment to its existing underground petroleum pipeline, CSFM 796 (pipeline), located in the Department of Water Resources right of way. The equipment installed includes 18 anodes, six anode shunt panels, 11,800 lbs. of RS-3 coke breeze, 3/4-inch PVC conduit, 1-inch PVC conduit, 2-inch PVC conduit, anode cable, pipe header cable, solar panels mounted on a 6-inch diameter by 15-feet tall solar post, a Dairyland solid-state decoupler (SSD) mounted on a 22.5-inch-long by 13.31-inch-wide by 36-inch-tall fiberglass mounting pedestal, and a 24-inch by 24-inch by 48-inch-tall Bison pedestal cabinet containing the CP power supply, solar charge controller, ring main unit, and batteries. The anodes and the cables will be installed underground. The solar post, SSD pedestal, and pedestal cabinet will be installed above ground. To install the underground equipment, an air knifing truck will be used to dig six shallow wells approximately 6 feet away from the pipeline; a drilling truck with an auger rig will drill into the shallow wells to increase their size to approximately 12-inches in diameter and 49-feet deep. Three anodes with attached anode cables and 2-inch PVC conduit will be placed in each well. RS-3 coke breeze will be poured into the wells as backfill. Next, a 134-foot-long by 3-foot-wide by 2-foot-deep trench will be excavated to expose the pipeline and install 2-inch PVC conduit and pipe header cables. The PVC conduit will be placed along the length of the trench, and the pipe header cables will be pushed through that PVC conduit. The pipe header cables will be attached to an existing, above ground junction box and to the outside of the pipeline; the pipe header cable will be connected to the pipeline where the above ground CP equipment will be placed. To connect the cables to the pipeline, the coating on the pipe will be removed from an 8-inch by 5-inch area, lugs attached to the cables will be pin brazed, and the coating will be repaired. To install the above ground equipment, a 30-inch long by 30-inch wide by 8-inch-tall concrete foundation will be poured where the pedestal cabinet will be placed; an 18-inch diameter by 9-foot-deep concrete foundation will be poured where the solar post will be placed. After the concrete has cured, the pedestal cabinet and solar post will be installed on the concrete foundations, and the SSD pedestal will be placed next to them and will be buried about a foot below the ground surface and approximately 3 to 5 feet from the pipeline. Next, the underground equipment that was installed will be connected to the above ground equipment by attaching the anode and pipe header cables to the CP power supply and the SSD. This section of the anode and pipe header cables will be placed inside 1-inch PVC conduit. The solar cables will be placed in 3/4-inch PVC conduit extending from the bottom of the solar post to the bottom of the pedestal cabinet. The newly installed CP equipment will be energized and tested, and the excavated area will be backfilled, compacted, and restored to original contours. A 16-feet by 16-feet by 6-feet-tall chain link fence enclosure will be installed around the above ground equipment.

Similar Contracts

Same NAICS industry code

NAICS: 237120
New
Federal
Concord-Fuel System Repairs
Solicitation # W9128F26RA075
The Concord-Fuel System Repairs project, managed by the U.S. Army Corps of Engineers Omaha District, involves comprehensive upgrades to the fueling systems at the Army Aviation Support Facility in Concord, New Hampshire. This 100% Small Business Set-Aside project under NAICS 237120 focuses on the design, construction, and testing of critical infrastructure. Key technical requirements include replacing grounding and high-level shut-off valves for F-24 tanks, extending tank catwalk platforms, and installing a relief discharge check valve on Tank 2. The scope also encompasses the installation of a truck offload meter, a visual fuel flow indicator, a filter separator maintenance platform, and a heated emergency eyewash station certified to ANSI/ISEA Z358.1. Additional facility improvements include the installation of protective pipe bollards for the offload/fillstand, a new ground verification system for offload operations, and the replacement of the equipment shelter ground system. A primary component of the project is the complete supply, installation, and testing of an Automatic Tank Gauging (ATG) system for fuel storage tanks 1 and 2. All work must adhere to strict regulatory standards, including UFC 3-460-01, NFPA 30, and EM 385-1-1 safety requirements. Award is based on the submission of a technically acceptable proposal in accordance with the Statement of Work, with the solicitation expected to be issued around October 7, 2026, and closing on or about November 6, 2026.
W071 Endist Omaha

POSTED

about 11 hours ago

DEADLINE

in 15 days
View Details
NAICS: 237120
New
International
Civic Yards Fuel Site Upgrades
Solicitation # 2026-085
The City of Red Deer is seeking proposals for the Civic Yards Fuel Site Redevelopment project under solicitation 2026-085. The scope of work involves a comprehensive assessment, engineering design, and the upgrade or replacement of aging fueling infrastructure, including fuel dispensers, concrete pads, and fuel monitoring systems such as Petro-Vend and Maglink. The selected proponent will provide end-to-end services encompassing procurement, construction management, testing, commissioning, and staff training. Proposals must be submitted electronically via the bids and tenders platform by October 16, 2026, at 4:00:59 P.M. Alberta Time. The contract includes a two-year warranty period from the date of installation or commissioning and requires the submission of as-built drawings within 90 days of substantial completion. Financial security is a key requirement, with the successful contractor providing both a performance bond and a labour and material payment bond, each valued at 50 percent of the contract price. Payment terms are set at 30 days from receipt of invoice, though the City may withhold 20 percent of fees based on performance and 5 percent until as-built drawings are received. Safety compliance is mandatory, requiring a current COR or SECOR certification endorsed by the Government of Alberta or an equivalent safety program. Award selection is based on a multi-stage evaluation of mandatory requirements, rated criteria, and optional interviews, with a tie-breaking preference for the highest score in the proposed solution and methodology.
City of Red Deer

POSTED

3 days ago

DEADLINE

in 25 days
View Details
NAICS: 237120
New
SLED
Gas Station Renovation Naval Base Kingsbay
Solicitation # P27-4200-09
The Camden County Board of Commissioners is soliciting competitive sealed proposals under RFP #P27-4200-09 for the turn-key renovation of the NEX Mini Mart and Gas Station at Naval Submarine Base Kingsbay. The project involves a comprehensive overhaul of fuel storage, dispensing, electrical, and POS infrastructure, including the removal of old underground storage tanks and the installation of new USTs, piping, and Gilbarco dispensers. The work must be executed in six phases over a 90-day window following the Notice to Proceed, with a mandatory pre-proposal meeting scheduled for October 1, 2026. All work must comply with EPA, Georgia EPD, DoD, and NFPA standards, and final acceptance requires third-party tightness testing and factory-certified commissioning by technicians from Gilbarco, Veeder-Root, and Verifone. Proposals are due by 2:30 p.m. on October 15, 2026, and must be submitted in a sealed envelope to the Camden County purchasing office. Submission requirements include one original and three copies of the proposal, featuring a notarized E-Verify affidavit, a signed W-9, and a detailed fee schedule. The contract will be awarded to the most responsible and responsive bidder based on price, equipment quality, and warranty. Selected contractors must provide performance and payment bonds totaling 100% of the contract amount, maintain at least $1,000,000 in liability insurance, and ensure all personnel pass the Defense Biometric Identification System security clearance for base access. Payment is structured as 90% of approved estimates within 30 days, with a 10% retainage held by the owner.
Camden County Board of Commissioners

POSTED

4 days ago

DEADLINE

in 24 days
View Details
NAICS: 237120
New
Federal
117 Fuel Tank Removal
Solicitation # W50S6M26QA018
Solicitation W50S6M26QA018 is a total small business set-aside for the 117th Air Refueling Wing in Birmingham, Alabama, to provide non-personal services for the environmental closure and removal of three 5,500-gallon steel, double-walled fuel tanks. The scope of work includes the removal of associated catwalks, scaffolding, and electrical components, including all wiring and conduit leading into Building 40. The contractor is responsible for purging the tanks, disposing of fuel and water mixtures, and ensuring all activities comply with EPA and Air Force regulations, as well as ANGETL, ANG Handbook, and Unified Facilities Criteria. The period of performance is 90 days, spanning from September 30, 2026, to January 8, 2027. The government intends to award a Firm Fixed Price contract based on the best value, evaluating price, technical acceptability, and past performance. Offerors must be registered in SAM.gov and submit a complete package including a signed SF 1449, a priced CLIN schedule, and two to three past performance references by September 23, 2026. A site visit is highly encouraged on September 17, 2026, and requires pre-registration with security details. Payments will be processed monthly in arrears through the Wide Area Workflow system. The project falls under NAICS code 237120 and adheres to specific labor standards and cybersecurity requirements.
W7MT Uspfo Activity Alang 117

POSTED

5 days ago

DEADLINE

in 1 day
View Details
NAICS: 237120
New
SLED
Camp Washoe Gas Upgrade
Solicitation # 43ADG-S4017
The Nevada National Guard Office of the Military is soliciting proposals under solicitation 43ADG-S4017 for gas supply line restoration services at Camp Washoe in Reno, Nevada. The project involves the installation of approximately 160 to 170 linear feet of 2-inch polyethylene gas service pipe, including all necessary trenching, excavation, and final surface restoration. The selected contractor will be responsible for obtaining all required City of Reno permits for pavement cutting and traffic control, coordinating with NV Energy and the NVARG Project Manager, and ensuring the installation is code-compliant according to the Gas Distribution Guide Vol. 15. A mandatory site visit was scheduled for October 16, 2026, and final proposals must be submitted via nevadaepro.com by November 10, 2026. Award decisions will be based on the best interest of the State, evaluating factors such as competence, experience, personnel, and cost, with a 30 percent weight assigned to the cost factor and a five percent preference for Nevada-based businesses. Contractors must provide a minimum one-year warranty on all labor and materials. Strict security and compliance requirements are in place, including mandatory background checks via Annex D for all personnel, proof of liability and worker's compensation insurance naming the Office of the Military as additionally insured, and adherence to State of Nevada Occupational Safety and Health Standards. Payment will be processed via electronic transfer, and vendors must be registered with the State of Nevada Controllers Office.
431 - Adjutant General and National Guard

POSTED

6 days ago

DEADLINE

in about 1 month
View Details

Ready to Pursue This Opportunity?

Get AI-powered intelligence on this solicitation and the ones like it

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS