This Solicitation opportunity from Department Of Defense was posted on April 22, 2026. The submission period has ended. Browse the details below for market research, or find similar active opportunities.
CATHETER AND CONNEC
Contract Overview
Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.
Active Opportunities Like This One
AI Contract Overview
The catheter and connector assembly is a sterile, disposable tracheal suction device designed for use during anesthesia procedures to facilitate aspiration. It features a clear, pliable plastic tube with a nominal diameter of 18 French, a whistle-tip design for effective suction, and a finger valve connector to control airflow. The unit includes up to two eyes for suction ports and measures 1.5 inches in length for compatibility with various tracheal tubes and airways. Constructed entirely of plastic, it is engineered to fit multiple sizes of tubing and is intended for use with tracheal anesthesia sets. The product is identified by NSN 6515-01-497-0680 and must be destroyed after 60 months. It is supplied in single units, with a procurement quantity of 10 pieces, and is subject to strict packaging, quality, and defense information requirements as outlined in the DLA Master List of Technical and Quality Requirements. The contract is issued under solicitation SPE2DS-26-T-003H by the Department of Defense’s Medical Supply Chain, with a response deadline of April 28, 2026, and a delivery requirement within five days of award.
General Info
Agency
NAICS
Place of Performance
USASet-Aside
Documents
(1)AI Contract Breakdown
Uniform Contract FormatWhat is UCF?
Uniform Contract Format (UCF) uses AI to break down any contract into standardized sections—scope, pricing, deliverables, and evaluation criteria.
Timeline
Submission Closed
Organization & Contact Information
Full Description
CATHETER AND CONNECTOR,SUCTION,TRACHEAL,,
TRACHEAL; SHAFT EYE QUANTITY 1; TIP TYPE WHISTLE;
CONNECTOR TYPE FINGER VALVE; CORE FABRICATION METHOD,,
NOT WOVEN; NOMINAL DIAMETER 18.000 FRENCH; CATHETER &
CONNECTOR SUCTION TRACHEAL E14 TB 18"FR PLAS STER DIS;
2 EYES MAX.; CLEAR PLIABLE TUBE,1 1/2 IN. (4 CM) LG;
WILL FIT VARIOUS SIZE TUBING AND PASS THROUGH ALL TYPES
OF TRACHEAL TUBES AND AIRWAYS; USED WITH TRACHEAL
ANESTHESIA SET; 6515-00-299-8687; FOR ASPIRATION DURING
ANESTHESIA; DESTROY AFTER 60 MONTHS; MATERIAL PLASTIC
OVERALL; STYLE DESIGNATOR TRACHEAL TUBE, CONNECTOR AND
ELBOW
UNIT OF ISSUE: EACH
..
RA001: THIS DOCUMENT INCORPORATES TECHNICAL AND/OR QUALITY REQUIREMENTS
(IDENTIFIED BY AN 'R' OR AN 'I' NUMBER) SET FORTH IN FULL TEXT IN THE
DLA MASTER LIST OF TECHNICAL AND QUALITY REQUIREMENTS FOUND ON THE WEB
AT:
http://www.dla.mil/HQ/Acquisition/Offers/eProcurement.aspx http://www.dla.mil/HQ/Acquisition/Offers/eProcurement.aspx
FOR SIMPLIFIED ACQUISITIONS, THE REVISION OF THE MASTER IN EFFECT ON THE SOLICITATION ISSUE DATE OR THE AWARD DATE CONTROLS. FOR LARGE ACQUISITIONS, THE REVISION OF THE MASTER IN EFFECT ON THE RFP ISSUE DATE APPLIES UNLESS A SOLICITATION AMENDMENT INCORPORATES A FOLLOW-ON REVISION, IN WHICH CASE THE AMENDMENT DATE CONTROLS.
..
RD003, COVERED DEFENSE INFORMATION POTENTIALLY APPLIES
..
RP001: DLA PACKAGING REQUIREMENTS FOR PROCUREMENT
..
RQ011: REMOVAL OF GOVERNMENT IDENTIFICATION FROM NON-ACCEPTED SUPPLIES
..
BIDDER: PLEASE SPECIFY SOURCE AND PART
NUMBER BEING SUPPLIED.
ADEQUATE DATA FOR THE NSN/Part Number: 6515-01-497-0680 Quantity: 10 EA Purchase Request: 7016436196QTY: 10 Delivery: 5 days ADO
More opportunities from Department Of Defense → MEDICAL SUPPLY CHAIN MD SURG FSF
Same awarding agency
Find Active Opportunities Like This
Get AI-powered intelligence on the opportunities still open
Every page of the solicitation package shredded into a compliance breakdown
AI-powered matching based on your capabilities and past performance
Competitor and incumbent history on the requirement
Automated alerts on amendments, Q&A deadlines, and award
Join 650+ contractors already using CLEATUS
