Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, October 28 at 2:00 PM ET

Register Free →

This Combined Synopsis/Solicitation opportunity from Department Of Homeland Security was posted on August 18, 2023. The submission period has ended. Browse the details below for market research, or find similar active opportunities.

CGC Stratton - NR3 SSDG Generator Bearings Out of Tolerance

Closed
70Z08523QP0022275Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

Active Opportunities Like This One

NAICS: 336611
New
SLED
F&W, 2018 Munson Packman Boat Repower project
Solicitation # 2018 Munson Packman Boat Repower
The Confederated Tribes of the Colville Reservation is soliciting proposals for the complete repower of a 30 foot Munson landing craft. The selected contractor will be responsible for the decommissioning and removal of two existing Honda BF250A outboard engines and the procurement and installation of two new Honda BF250D Drive-by-Wire outboards. The scope of work is divided into six phases, encompassing structural transom inspections, the installation of Honda iST electronic control heads at dual helm stations, integration with the SeaStar Power Assist steering system, and a comprehensive fuel system overhaul using USCG Type A1-15 lines. The project concludes with NMEA 2000 network integration, digital gauge installation, and a minimum two hour sea trial to validate performance and safety protocols. To ensure factory warranty coverage, the contractor must maintain active Honda Marine Authorized Dealer or Service Center status. The vessel will be delivered via trailer to the contractor facility, which must provide a secure, fenced yard or indoor shop. Award evaluation is based on a weighted criteria of cost, technical expertise, and TERO status, with a preference for Colville Business Enterprises. Proposals must be submitted in PDF format by November 13, 2026. Final contracts are subject to tribal appropriation and may require a performance bond for values exceeding 100,000 dollars or a 25 percent retainage.
Confederated Tribes of the Colville Reservation

POSTED

about 3 hours ago

DEADLINE

in 24 days

General Info

NAICS

336611 - Ship Building and Repairing

Place of Performance

Alameda, CA, 94501, USA

Set-Aside

SBA

Documents

0

No documents available

Documents will appear here when they are available.

AI Contract Breakdown

Uniform Contract Format

No documents to break down

The breakdown needs solicitation documents. None were found from this contract's source.

Timeline

PhaseClosed
Posted

Combined Synopsis

Response Deadline

Deadline has passed

Submission Closed

Find active opportunities like this

Start your free trial to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyDepartment Of Homeland Security → Sflc Procurement Branch 2(00085)
Contacts2 people available
OfficeALAMEDA, CA, 94501, USA

Full Description

Show more
This is a combined synopsis/solicitation for commercial items/services prepared in accordance with the format in FAR Subpart 12.6 as supplemented with additional information included in this notice. Request for Quotations number is 70Z0-8523-Q-P0022275 and is issued as a request for quotations (RFQ). This announcement constitutes the only solicitation; quotations are being requested and a written solicitation will not be issued. This Request for Quotations incorporates provisions and clauses in effect through Federal Acquisition Circular 2005-65 dated January 29, 2013. The NAICS Code is 336611. The small business size standard is 1250. This is a total small business set aside. All responsible sources may submit proposals that will be considered by the agency. The contract will be awarded on a firm-fixed-price basis using simplified acquisition procedures in accordance with FAR Part 13.5. All responses from interested vendors must be received on/before 0800 Pacific Time, Aug 28th, 2023, and will be reviewed by the Government. The United States Coast Guard Surface Force Logistics Center has a requirement for the following: Scope of Work: CGC STRATTON; #3 Generator Load Bank Testing, The CTR shall provide technical services and labor load testing for #1 SSDG. The CTR shall provide the following: Attend Daily Production Meeting to include Review of plan and requirements with Ship's personnel Completion of OEM checklist if available First and last names of all personnel. Perform all work IAW SFLC Standard Specification 0000 Certified technicians to supply all equipment needed to perform a load test IAW provided instruction Provide at least 250 of cable Provide Load Bank and operating personnel Provide detailed service report on findings and observations Coast Guard will provide the following: GFE: N/A Tagouts of all interfering equipment Remove interferences Electrical Power Removal and installation of bearing Clean work environment Period of Performance: 11 Sep 2023 - 15 Sep 2023 load banking. The Contractor is expected to quote for and provide services for 5 total days. If there are any questions, reach out to ESN Igor Guerrero, (206) 661-3986 Place of Performance: U.S. Coast Guard Base Alameda, Berth 1 1 Eagle Rd Alameda, CA, 94501 Load Testing Procedures: Testing plan. The Contractor shall submit a plan for break in and testing of the new SSDG in accordance with Caterpillar Publication SEBF9011-26, Cutter Operating Procedures, requirements of Paragraph 3.3 herein and TP 7119 (both for prime mover and National Oilwell Varco generator). Submit the testing plan no later than one week after the Arrival Conference in a CFR. See previous Load Bank Testing Plan below for an example. The Contractor shall obtain the Caterpillar Tech Rep's and the Generator Tech Rep's approval of the Testing Plan. No testing shall commence before COR approval and official acceptance by the Contract Officer (KO). The plan shall cover the following topics at a minimum: Emergency shutdown procedures Load bank specification and location Cable locations for load bank No-load tests Loaded tests Data to be collected during tests All proposed connections, cable and load bank configurations Load Banking. The Contractor shall provide a resistive load bank (i.e. 450 Volt, 1500 KW) with cabling and accessories to test the SSDG, estimate 250 of cabling for bidding purposes. The CTR must hook up to Bus Bar in the respective switchboard. The load bank shall be placed on the pier or the ship at the discretion of the COR. The Contractor shall run cables in overheads as much as possible to avoid trip hazards. The Contractor shall provide any additional labor or crane services as necessary for the setup, operation, and disassembly of the load bank and associated cabling or accessories. Loaded Operational Test. The Contractor shall execute the loaded portion of the Test Plan. During the tests, all measured parameters shall be recorded and be within acceptable ranges. Submit a CFR. During the operational test, record all engine and generator parameters on a log sheet (to be provided by ships force). If any unusual readings are experienced, immediately secure the engine and troubleshoot to determine the cause. Any unusual operating conditions caused by work on this item shall be corrected by the Contractor. The Contractor shall provide engine diagnostic data directly from the engine. Coast Guard personnel will operate all shipboard machinery and equipment. Previously Used Load Bank Testing Procedure: Safety: At any point in the load test or operational testing period if the need presents its self the engine - Prime mover may be shut down by the Tech rep with communication to the USCG operational Engineer utilizing the local EOS, E stop or shut down from the switch gear. Any of the three options will automatically open the SSDG buss breaker. The cool down of the load bank will not be a consideration of a life safety event or mechanical failure. Load bank cables will be connected at USCG#2 main buss breaker. Accessed from the back side of the switch gear after proper LOTO procedures have been performed and dead buss is verified. 6 - 8 cables per phase are to be utilized and connected to the buss with mechanical lug blocks bolted to the existing buss access door in the back side of the switch board. All cables and blocks are to be insulated after installation with rated arc flash blanket - wrap. Load bank cables will be routed out of the engine room via hallway utilizing ladder 2-45-1 rescue hatch door. Load bank cables will be at or under 250 foot length specified. 1500KW Load bank will be set on the pier closest to the rescue hatch. If proper external power is available for load bank fan operation external power will be utilized however not required. Running no load testing. No load testing will consist of running the engine at idle rpm until the engine coolant temperature reaches 140 deg. F during that warm up time safety testing will be performed for oil psi and temp warning and shut down and coolant temp. warning and shutdown. Ship board alarm verification will be observed at that time as well. Load bank test It is proposed that the load bank test be done to the following: Warmup until coolant temp reached 140 deg F. Thirty minutes at 25% load Thirty minutes at 50% load Thirty minutes at 75% load Two hours at 90-100% load Fifteen minute cooldown Load bank readings will be taken every 15 minutes of the following. Engine, Coolant temp, oil pressure, battery voltage, boost, intake air temp after the aftercooler, exhaust stack temp left and right bank if available and fuel rate GPH. In addition to the generator load test form a Caterpillar steady state engine performance file will be recorded off of the engine ECM to record all related available information. Generator information, voltage reading per phase, amperage readings per phase, HZ, bearing and winding temps if installed. Pre and post-test PSSRP will be saved off of the ECM to provide verification of all available diagnostic codes and events. All electronic files and reports will be sent to the COR and distributed through proper channel. Questions and quotes shall be emailed to Eric.T.Foster@uscg.mil and Igor.Guerrero@uscg.mil. Contractors are responsible for verifying receipt of quotes. INTERESTED VENDORS PLEASE SIGN AN OFFICIAL QUOTE WITH A SAM.GOV REGISTERED DUNS NUMBER AND EMAIL TO Eric.T.Foster@USCG.MIL and Igor.Guerrero@uscg.mil.

More opportunities from Department Of Homeland Security → Sflc Procurement Branch 2(00085)

Same awarding agency

Find Active Opportunities Like This

Get AI-powered intelligence on the opportunities still open

Every page of the solicitation package shredded into a compliance breakdown