Closed-Circuit Wind Tunnel (24-inch test)
Contract Overview
Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.
AI Contract Overview
The U.S. Army Contracting Command-Redstone is conducting market research through a Request for Information to identify capable vendors for the procurement of a closed-circuit wind tunnel to be installed at the Army Primary Standards Laboratory in Redstone Arsenal, Alabama. This specialized facility is intended for use by USATA Engineers and Technicians to support high-precision calibration activities using a Laser Doppler Velocimetry system, which requires the generation of extremely low air velocities down to 0.15 meters per second with a turbulence intensity under 1 percent. The wind tunnel must feature a 24-inch by 24-inch test section with optical-quality glass sidewalls to accommodate a 532-nanometer, 500-milliwatt argon-ion laser, and include seven sealable instrument ports that accept probes ranging from 4.3 to 15.9 millimeters in diameter. A 3/8-inch Swagelok bulkhead fitting upstream of the test section is required for the introduction of Bis(2-ethylhexyl) subacute seed particles, and the test section must include grooves at approximately 90 percent of its length to allow installation of adjustable nozzle restriction plates. A 15-inch section of the test area located six inches upstream of these plates must be replaceable without compromising the integrity of the wind tunnel circuit. The system must have a centrifugal fan with vibration isolation, driven by a variable-frequency drive controlled exclusively through LabVIEW software with no wireless or internet connectivity, and must operate at a maximum speed of approximately 50 meters per second while maintaining the specified turbulence criteria. The entire system, including all associated components, must not exceed 32 feet in length, 8 feet in width, or 7.5 feet in height. Design proposals must include validated quantitative analysis, such as computational fluid dynamics simulations, to demonstrate that all performance requirements are met. The solicitation number is PANRSA-26-P-0000-037658, and responses are due by July 15, 2026, to be submitted via email to designated Army contracting personnel. This is strictly a market research effort under FAR 15.201(e) and does not constitute a solicitation for contract award; no contract value, delivery schedule, or payment information has been established at this stage. Respondents are required to provide their CAGE code, Unique Entity Identifier, business size classification according to NAICS code 54
General Info
Agency
NAICS
Place of Performance
Redstone Arsenal, AL, 35898, USASet-Aside
Timeline
Response Deadline
Organization & Contact Information
Full Description
The Closed-Circuit Wind Tunnel (24-inch test) shall include the following specifications or equivalent (if not brand name):
Requirements:
- This wind tunnel must be a closed circuit, as the operation of an LDV system requires seed particles to be added to the air stream – in this case, a substance called Bis(2-ethylhexyl) subacute. The wind tunnel thus needs to be fitted with a 3/8-inch Swagelok bulkhead fitting placed upstream of the test and transitional sections.
- This wind tunnel must have a maximum operating speed of approximately 50 meters per second (~9900 feet per minute). The test section walls must have 25.908 millimeter (~1.02-inch)-thick grooves placed at approximately 90 percent of the total length of the test section as measured from the entrance in which specialized nozzle restriction plates can be affixed to adjust the operating range and achieve an air speed of 0.15 meters per second (~30 feet per minute). The typical turbulence intensity across this operating range must be less than 1 percent, where turbulence intensity is defined as the root-mean-square of velocity fluctuations divided by the average test section velocity.
- This wind tunnel must have a test section height and width of 60.96 centimeters by 60.96 centimeters (~24 inches by 24 inches). Test section length can vary if the design meets the following requirements: The test section must have at least two sealable ports or fittings for the insertion of instruments of various sizes, such as Pitot-static tubes and hotwire anemometers. These ports or fittings must accommodate the following instrument diameters: 4.3 mm (~0.188 in); 6.3 mm (0.25 in); 7.9 mm (0.313 in); 9.5 mm (0.375 in); 10.1 mm (0.4 in); 12.7 mm (0.5 in); 15.9 mm (0.625 in). The test section must also be designed such that a 15-inch section of the usable test area located approximately 6 inches upstream of the nozzle restriction plates can be replaced with a test item without introducing any leaks into the circuit. The total footprint of the tunnel and all associated systems must not be larger than 32 feet in length, 8 feet in width and 7.5 feet in height. Additionally, portions of the test section sidewalls must be made of optical-quality glass to minimize interference with laser propagation. The argon-ion continuous-wave laser used in this application has a max wavelength of 532 nanometers and 500 milliwatts output power.
- The wind tunnel must have a centrifugal fan design. The fan should be isolated from the rest of the tunnel system to minimize vibration. The fan must be controlled by a variable-frequency drive (VFD) connected to a motor of appropriate size and power to meet the air speed requirements listed above. The VFD must be implemented such that an operator could use computer software or manual input to control the drive and automate its function. The computer-VFD interface must not rely on internet or wireless connections, such as Bluetooth or WiFi. This interface must be programmable via National Instruments’ LabVIEW software.
- Any design submitted must be shown to meet the specific air speed and turbulence requirements listed above through a quantitative analysis, such as by computational fluid dynamics (CFD) simulations or other appropriate methods.
-------------------------------------------------------------------------
Delivery Location/Address: U.S. Army TMDE Activity, Attn: Michael Tyler, Building 5435 Fowler Road, Redstone Arsenal, AL 35898