Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, October 28 at 2:00 PM ET

Register Free →

This Combined Synopsis/Solicitation opportunity from Department Of Defense was posted on September 11, 2012. The submission period has ended. Browse the details below for market research, or find similar active opportunities.

Cold Environmental Room

Closed
F4AB002180A001Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

Active Opportunities Like This One

NAICS: 333415
New
DIBBS
COOLING COIL, AIR, DUCT
Solicitation # SPE7M0-27-T-0178
Solicitation SPE7M0-27-T-0178 is issued by the DLA Weapons Support Maritime Supply Chain ESOC Buys for the procurement of one duct type air cooling coil, identified by NSN 4130011916131 and part number 19-80-2979M. The requirement is classified under NAICS code 333415 and is set aside for small businesses, with a specific price evaluation preference for HUBZone concerns. The original required delivery date is October 1, 2026, with a delivery window of five days after receipt of order. Delivery is FOB Origin, and both inspection and acceptance will occur at the destination, specifically the Puget Sound Naval Shipyard IMF in Bremerton, Washington. The contract mandates strict adherence to technical and quality requirements via the DLA Master List and specifies packaging and marking standards according to MIL-STD-2073-1E and MIL-STD-129. Special restrictions are in place regarding the use of mercury and the removal of government identification from non-accepted supplies. Administrative requirements include electronic invoicing through the Wide Area WorkFlow system and submission of all quotes via the DLA Internet Bid Board System by October 19, 2026. Key regulatory clauses apply, including the Buy American and Balance of Payments Program, NIST SP 800-171 assessment requirements, and safeguarding of covered defense information.
DLA WEAPONS SUPPORT MARITIME SUPPLY CHAIN ESOC BUYS

POSTED

about 19 hours ago

DEADLINE

in 2 days

General Info

NAICS

333415 - Air-Conditioning and Warm Air Heating Equipment and Commercial and Industrial Refrigeration Equipment Manufacturing

Place of Performance

501 Illionois Avenue Suite 5, TYNDALL AFB, FL, 32403, USA

Set-Aside

SBA

Documents

3

Cold+Room+SOO-13Aug12.doc

DOC

Question+and+Answers+2.docx

DOCX

Questions+and+Answers.docx

DOCX

AI Contract Breakdown

Uniform Contract Format

Contract not broken down yet

CLEATUS splits the solicitation into Uniform Contract Format (UCF) sections: scope, pricing, deliverables, and evaluation criteria.

Timeline

4 updates
PhaseClosed
Posted

Combined Synopsis

Notice updated

The notice description changed.

Notice updated

Response deadline changed from Aug 27, 2012 to Sep 4, 2012. The notice description changed.

Notice updated

Response deadline changed from Sep 4, 2012 to Sep 11, 2012. The notice description changed.

Notice updated

The notice description changed.

Response Deadline

Deadline has passed

Submission Closed

Find active opportunities like this

Start your free trial to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyDepartment Of Defense → FA4819 325 Cons Pkp
Contacts2 people available
OfficeTYNDALL AFB, FL, 32403, USA
Office AddressTYNDALL AFB, FL, 32403, USA
Contacts
Yvette M. KellyContract Specialist
Melissa J. BlairContract Officer

Full Description

Show more
F4AB002120A001 Environmental Room Amendment 03, 11 Sep 12 Questions & Answers #3 7 Sep 12 Q1: How much water will be introduced during the -5 - C? A1: 0.03402 ounces per minute Q2: Are there any height requirements for the ceiling? A2: The ceiling must remain at a minimum of 6 feet tall. Q3: Will a breaker need to be supplied? A3: There is an existing breaker, however if the amperage changes a new breaker will need to be installed. Q6: Are their multiple rooms fed from the same breaker? A6: There is one (1), three (3) phase breaker for each room Q4: What is the length of the test? A4: Test times will range between 30 minutes to 2 hours; however they should not be limited solely to these times. Q5: What is the current distance between the ceiling of the room and the roof? A5: Approximately sixteen (16) feet from the floor of the room to the roof deck and approximately eight (8) feet from the ceiling of the room to the roof deck. Q7: Are there any specific environmental procedures that need to be addresses when demoing/removing the existing environmental systems? A7: An AF From 332 shall be submitted to the Civil Engineering (CE) flight on Tyndall by the customer. Once a 332 is approved either CE or the contractor may perform the work. However, CE must track all progress and the refrigerant must be disposed of in accordance with current enviromental standards. Q8: After award, when will the room be ready to start work? A8: 2 business days after notification of award Q9: During what times will the contractor have access to the facilities for the work to be performed? A9: 0700-1600 Central Time, Monday thru Friday

More opportunities from Department Of Defense → FA4819 325 Cons Pkp

Same awarding agency

NAICS: 561210
Federal
TYNDALL AFB - RANGE AND OPERATIONS SUPPORT (RAOS)
Solicitation # FA481927CY001
Tyndall Air Force Base is conducting market research via a Sources Sought Notice to identify qualified 8(a) small business concerns for Range and Operations Support (RAOS) under NAICS code 561210. The anticipated acquisition will be a competitive 8(a) set-aside. Interested firms must provide a capability statement including company details, UEI, CAGE code, 8(a) eligibility, and relevant experience performing work of similar size and complexity. The response deadline for this market research is October 22, 2026. The scope of work involves providing technical services and labor support to maintain and operate test ranges for the Air Force Civil Engineer Center at Tyndall AFB, Florida. Key responsibilities include the operational capability of the Materials Testing Systems laboratory, In-Door Ballistic range, Fire Training and Test Facility, and Sky X range to support research, development, test and evaluation, and technology transition testing. The contractor will be required to manage vehicles, equipment, and facilities, while adhering to Air Force standards and explosive safety regulations. Administrative requirements include invoicing through the Wide Area Workflow system and maintaining a Purchase Expense Spreadsheet. Personnel requiring access to classified information must hold at least a Secret clearance and comply with specific cybersecurity mandates, including DAFMAN 17-1301 and AFI 17-130. The contractor must provide a part-time on-site contract lead and ensure all staff complete mandatory Total Force Awareness Training. Performance is primarily on-site at government installations during normal operating hours of 6:00 AM to 5:00 PM Central Time.
Facilities Support Services

POSTED

14 days ago

DEADLINE

in 2 days
View Details

Find Active Opportunities Like This

Get AI-powered intelligence on the opportunities still open

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS