Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, October 28 at 2:00 PM ET

Register Free →

This Combined Synopsis/Solicitation opportunity from Department Of Defense was posted on May 27, 2021. The submission period has ended. Browse the details below for market research, or find similar active opportunities.

Computed Tomography (CT) contrast injectorUnited States Naval Hospital Yokosuka, Japan

Closed
N6264521Q0021Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

Active Opportunities Like This One

NAICS: 334510
New
Federal
Automated Ultrasound-Based, Super Intelligence (SI)-Enabled Fracture Detection
Solicitation # BARDA-FY27-10192026
The Center for Biomedical Advanced Research and Development Authority (BARDA) has issued Sources Sought Notice BARDA-FY27-10192026 to identify innovative medical countermeasure technologies for the rapid triage of musculoskeletal injuries, such as fractures and soft tissue injuries of extremities. This request for information is intended for planning and market research purposes to assess commercially available or nearing-commercial technologies that utilize Super Intelligence (SI) and machine learning for automated ultrasound-based fracture detection. The goal is to find standalone, point-of-care devices that can operate in emergency departments, urgent care centers, and austere field settings without relying on traditional imaging infrastructure like X-ray or CT scans. The desired technology must feature automated volumetric capture, 3D-rotatable modeling, and SI-enabled image processing that outperforms human imaging experts and has undergone FDA 510k clearance processes. BARDA is interested in ruggedized, portable units with sufficient battery life for disaster response, interoperability with electronic health record systems, and minimal training requirements for non-specialist operators. Potential acquisition strategies being explored include direct purchases, leases, or vendor-managed inventory arrangements. Interested small businesses and other than small business concerns under NAICS code 334510 must submit their capabilities statements by 1:00 p.m. Eastern Time on November 18, 2026. Submissions must include separate Technical and Business Representation sections, each limited to 10 pages in 12-point Times New Roman font, and be emailed to Justin Moore and Richard Hall. Responses should detail the company's manufacturing capabilities within the United States, regulatory maturity, supply chain resilience, and cybersecurity standards for handling sensitive patient health information.
Barda - Aspr / Daappo / Barda Dcma

POSTED

about 10 hours ago

DEADLINE

in 29 days

General Info

NAICS

334510 - Electromedical and Electrotherapeutic Apparatus Manufacturing

Place of Performance

MD, JPN

Set-Aside

NONE

Documents

2

Combined+Synopsis+Updated.docx

DOCX

N6264521Q0021+Amendment+I.pdf

PDF

AI Contract Breakdown

Uniform Contract Format

Contract not broken down yet

CLEATUS splits the solicitation into Uniform Contract Format (UCF) sections: scope, pricing, deliverables, and evaluation criteria.

Timeline

1 update
PhaseClosed
Posted

Combined Synopsis

Notice updated

Response deadline changed from May 17, 2021 to Jun 10, 2021. The point of contact changed.

Response Deadline

Deadline has passed

Submission Closed

Find active opportunities like this

Start your free trial to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyDepartment Of Defense → Naval Medical Logistics Command
Contacts1 person available
OfficeFORT DETRICK, MD, 21702-9203, USA
Office AddressFORT DETRICK, MD, 21702-9203, USA
Contacts
Gerrie M. Johnson

Full Description

Show more
This solicitation is being issued as a Request for Proposal (RFP). United States Naval Hospital (USNH) Yokosuka requires a computed tomography (CT) contrast injector for use by the Radiology Department during routine and emergent CT procedures with intravenous contrast. The system shall be ceiling-mounted and feature integrated auto load, auto retract, auto prime, and auto syringe sensing. The injector shall have dual syringes, each with a capacity of at least 200 mL. The system shall be capable of syringe fluid heating. Flow rate range shall be inclusive of at least 0.1 - 10 mL/sec. Delivery pressure range shall be inclusive of at least 40 - 325 psi. The system shall be capable of saline flush, dual flow, extravasation detection, and air detection. For operator control, the system shall include a touch screen monitor with real-time flow control, real-time pressure reading, protocol memory and at least 6 hours of history memory. Operator workstation shall be included. The system shall be capable of full integration with the currently installed GE Optima CT660 at USNH Yokosuka. The system shall be capable of a scan delay range inclusive of at least 0-300 seconds. The system shall be capable of a pause range inclusive of at least 1 - 900 seconds. The system shall be capable of maximum hold time of at least 20 minutes. The system shall include two (2) operator manuals and two (2) service manuals in English and Japanese. The equipment shall be operable at 100VAC, 50 Hz. Vendors are given the option to deliver to Naval Medical Center (NMC) San Diego. Transportation of the equipment from NMC San Diego to USNH Yokosuka can be arranged by the Government. Direct shipment to USNH Yokosuka by the vendor is preferred and is an enhancing factor. The system, including claims made for the product, shall be compliant with Food and Drug Administration (FDA) regulations, with respect to marketing and delivering medical products for use in the United States of America. These requirements shall apply even if delivery is requested outside of the United States of America. The system shall be installed in compliance with the Occupational Safety and Health Administration (OSHA) requirements. Contractor shall be an Original Equipment Manufacturer (OEM) authorized dealer, authorized distributor, or authorized reseller for the proposed equipment/system such that OEM warranty and service are provided and maintained by the OEM. All software licensing, warranty, and service associated with the equipment/system shall be in accordance with the OEM terms and conditions. Upon delivery, the contractor shall be responsible for uncrating the unit/system, transporting it through the facility to the location of intended use for installation, and removing of all trash created in this process. The vendor shall be responsible of de-installation and removal of current equipment. If interim storage is required, the vendor shall make arrangements for the storage.

Find Active Opportunities Like This

Get AI-powered intelligence on the opportunities still open

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS