Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, September 30 at 2:00 PM EDT

Register Free →

Concrete Reinforcing Steel (Supply & Install)

Active
State & Local

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

AI Contract Overview

Show more

This subcontract for Concrete Reinforcing Steel involves the supply and installation of rebar for prime contractors working on Tarrant Regional Water District facility projects. The scope of work requires the placement of reinforcing bars according to specific lap lengths and embedment tables, ensuring concrete cover is maintained within a plus or minus one quarter inch tolerance. All work must be performed in strict compliance with ACI 318 and the CRSI Manual of Standard Practice. The contractor is responsible for delivering a completed installed rebar grid along with certified test reports verifying the quality and grade of the steel. This opportunity is categorized under NAICS code 238110 and is managed by Infrastructure Engineering in Texas. The response deadline for this solicitation is October 15, 2026.

General Info

Subcontract for rebar supply and installation for Tarrant Regional Water District projects.

Documents

This scope was carved out of 26-093.

The full solicitation package (8 documents), including the RFP, is on the prime solicitation, not on this scope.

View the prime solicitation

RC1 and CC1 Electrical Building and Equipment Additions

AI Contract Breakdown

Uniform Contract Format

No documents to break down

The breakdown needs solicitation documents. None were found from this contract's source.

Timeline

Posted

subcontract

Response Deadline

Submission deadline

Response Deadline

Ready to pursue this opportunity?

Start your free trial to track this contract, build proposals with AI assistance, and manage your pipeline.

Organization & Contact Information

Show more
AgencyTexas → Infrastructure Engineering
ContactsNo contacts available
OfficeN/A
Office AddressN/A
ContactsNo contact information available

Full Description

Show more
Supplies and installs reinforcing steel (rebar) for prime contractors on Tarrant Regional Water District (TRWD) facility projects. Places reinforcing bars per lap lengths and embedment tables while maintaining specified concrete cover (± 1/4 inch) in compliance with ACI 318 and CRSI Manual of Standard Practice. Delivers installed rebar grid and certified test reports for steel quality and grade.

Similar Contracts

Same NAICS industry code

More opportunities from Texas → Infrastructure Engineering

Same awarding agency

NAICS: 541330
SLED
Engineering Services for Richland Chambers Lake Pump Station Chemical Improvements
Solicitation # 26-179
The Tarrant Regional Water District is soliciting Statements of Qualifications for engineering services to implement chemical improvements at the Richland Chambers Lake Pump Station. The primary objective of the project is to convert the existing aqua ammonia storage and feed system to liquid ammonium sulfate. The selected firm will be responsible for a comprehensive range of services, including project management, preliminary investigations, design, permitting, and procurement-phase services. Specific technical requirements include the design of chemical storage and feed systems, containment, piping, the demolition of existing chlorine systems, and SCADA-related design, with a strong emphasis on life safety, hazardous-material handling, and chemical compatibility. Qualified firms must submit their SOQs via the OpenGov Procurement Website by October 20, 2026, at 2:00 pm CT. Submissions must strictly adhere to formatting guidelines, including a maximum two-page cover letter, a one-page organization chart, one page of team leader resumes, and one page of past projects and references. A signed Conflict of Interest Questionnaire is mandatory, and no fee estimates or pricing information should be included in the submittal. The Tarrant Regional Water District will select the best qualified firm based on the SOQ review, potentially conducting interviews with the top three ranked firms. The awarded vendor must agree to the terms and conditions of the Standard PSA Engineer Option and provide the required insurance.
Engineering Services

POSTED

23 days ago

DEADLINE

in 22 days
View Details

Ready to Pursue This Opportunity?

Get AI-powered intelligence on this solicitation and the ones like it

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS