Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, October 28 at 2:00 PM ET

Register Free →

This Sources Sought opportunity was posted on March 9, 2011. The submission period has ended. Browse the details below for market research, or find similar active opportunities.

Construct Medium Voltage electrical substation

Closed
Reference_No_HHS-NIH-ORF-SBSS-11-009Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

Active Opportunities Like This One

NAICS: 236220
New
Construction of the Recharge Master Plan Update Basin Improvements Project Montclair Basin Improvements
Solicitation # construction-recharge-master-plan-update-basin-improvements-project-montclair-basin-improvements-2
The Construction of the Recharge Master Plan Update Basin Improvements Project Montclair Basin Improvements is a solicitation issued by RT Contractor Corp for the Inland Empire Utilities Agency. This project, located in California with a specific focus on the Riverside and Los Angeles project areas, is designated as a set-aside for Disadvantaged Business Enterprises (DBE) under the Department of Transportation. The solicitation was posted on October 21, 2026, with a response deadline of November 4, 2026. A critical component of this contract is strict adherence to six Good Faith Effort (GFE) requirements designed to secure project financing and expand upon State Water Resources Control Board standards. Bidders must provide proof of publicity, including online postings for 30 consecutive days and a one-day print newspaper advertisement, as well as evidence of utilizing the Small Business Administration and Minority Business Development Agency. These specific documents must be submitted with the bid package to avoid being deemed non-responsive. Additionally, documentation of DBE outreach may be submitted up to three business days after the bid closing date. Failure to comply with these GFE mandates will result in the disqualification of the proposal.
RT CONTRACTOR CORP

POSTED

about 6 hours ago

DEADLINE

in 14 days
NAICS: 236220
New
P084 NEXT GENERATION TORPEDO INTEGRATION LAB & P1016 Consolidated RDT&E Systems Facility – Newport, RI
Solicitation # p084-next-generation-torpedo-integration-lab-p1016-consolidated-rdte-systems-facility-newport-ri
J&J Contractors, Inc. is soliciting bids for the construction of the Next Generation Torpedo Integration Lab and the P1016 Consolidated RDT&E Systems Facility in Newport, Rhode Island. The project involves the creation of a 12,920 square foot multi-story steel frame laboratory and office facility featuring a shallow foundation, metal standing seam roof, and masonry and metal panel exterior walls. Additionally, Option 1 includes a separate 17,978 square foot laboratory facility with similar structural specifications and the demolition of Building 1272T, a 548 square meter engineering facility. The scope of work encompasses comprehensive site improvements, including landscaping, parking, exterior lighting, telecommunications, and underground stormwater retention systems. Pricing is requested across a wide range of trades, including demolition, abatement, concrete, masonry, structural steel, mechanical, electrical, plumbing, and fire protection. This is an SBA set-aside solicitation for small businesses and other designated disadvantaged business categories. All work must adhere to Davis Bacon Wage Rates and is exempt from sales tax. Interested parties must contact the primary point of contact to receive the formal bid invitation and documents via Building Connected before the response deadline of November 30, 2026.
J&J CONTRACTORS, INC.

POSTED

about 6 hours ago

DEADLINE

in about 1 month
NAICS: 236220
New
CITY OF GREENFIELD WASTEWATER TREATMENT PLANT UPGRADE PROJECT
Solicitation # city-greenfield-wastewater-treatment-plant-upgrade-project
The City of Greenfield Wastewater Treatment Plant Upgrade Project involves the construction of an upgraded 2.0 million gallons per day wastewater treatment plant located at 41901 Walnut Avenue in Greenfield, California. The project, managed by C. Overaa & Co., has a total duration of 915 calendar days and is divided into four distinct phases: site preparation including soil stabilization and facility relocation; construction of a packaged Membrane Bioreactor treatment plant, headworks, UV disinfection, and SCADA systems; decommissioning and demolition of existing facilities; and the completion of finish facilities including the Walnut Avenue extension for water and sewer services. A critical requirement of the project is maintaining the existing plant in service during the first two phases while ensuring compliance with General Order/NOA standards. This solicitation is open to small businesses, including certified veteran, women, and disadvantaged business enterprises, with a specific local hiring goal requiring 50 percent of the construction workforce to be residents of Monterey, San Benito, or Santa Cruz counties. Subcontractors must utilize the Textura electronic invoicing system and are responsible for associated service fees. Bids are due by November 10, 2026, following a mandatory pre-bid meeting held on October 5, 2026. Award acceptance is conditioned upon the subcontractor's full agreement to Overaa standard terms, including potential 100 percent performance and labor bonds and specific workers compensation insurance waiver of subrogation endorsements.
C. Overaa & Co.

POSTED

about 6 hours ago

DEADLINE

in 20 days
NAICS: 236220
New
P1102 Weapons Magazine and Ordnance Operations Facility, Naval Submarine Base New London, Groton, Connecticut
Solicitation # p1102-weapons-magazine-ordnance-operations-facility-naval-submarine-base-new-london-groton
J & J Contractors, Inc. is soliciting bids for the P1102 Weapons Magazine and Ordnance Operations Facility project located at the Naval Submarine Base New London in Groton, Connecticut. This comprehensive construction project has a duration of 1828 calendar days and involves the creation of six Containerized Long Weapons Storage units, two Box G magazines, and one Box H earth-covered high-explosive magazine. The scope includes the installation of overhead cranes, reinforced concrete floors, grounding and lightning protection, and intrusion detection systems. Additionally, the project requires the construction of a new Ordnance Operations building, a Truck Inspection facility, and a Sentry building, alongside the demolition of 18 existing magazines and two other buildings. The technical requirements encompass extensive sitework, including clearing, rock excavation, grading, and the implementation of rigid inclusions and load transfer mats for foundations. Due to the impact on existing wetlands, mitigation efforts are required. Infrastructure improvements include new access roads, paved loading areas, landscaping, and a complete electrical utility system featuring primary and secondary distribution, transformers, and telecommunications. This solicitation is set aside for various small business categories, including SDB, WOSB, HUBZone, and VOSB. Interested parties must respond by October 31, 2026.
J & J Contractors, Inc

POSTED

about 6 hours ago

DEADLINE

in 10 days

General Info

Agency

N/A

NAICS

236220 - Commercial and Institutional Building Construction

Place of Performance

Office of Research Facilities/Office of Acquisition 13 South Drive, Room 2E48 9000 Rockville Pike, BETHESDA, MD, 20892, USA

Set-Aside

SBA

Documents

0

No documents available

Documents will appear here when they are available.

AI Contract Breakdown

Uniform Contract Format

No documents to break down

The breakdown needs solicitation documents. None were found from this contract's source.

Timeline

PhaseClosed
Posted

Sources Sought

Response Deadline

Deadline has passed

Submission Closed

Find active opportunities like this

Start your free trial to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyN/A
Contacts2 people available
OfficeN/A
Organization / Agency
N/A
Office AddressN/A
Contacts
Kimberly GoodwinContract Specialist

Full Description

Show more
******************MARKET SURVEY************* THIS IS A MARKET SURVEY. THIS IS NOT A SOLICITATION OR REQUEST FOR PROPOSAL. RESPONSES TO THIS MARKET SURVEY SHALL BE FOR INFORMATION PURPOSES ONLY, WHICH WILL BE USED TO ASSIST THE NIH IN DETERMINING IF QUALIFIED SMALL BUSINESSES ARE AVAILABLE TO WARRANT SETTING ASIDE THIS ACQUISITION FOR SMALL BUSINESS. The Office of Research Facilities (ORF), The National Institutes of Health (NIH) is conducting a MARKET SURVEY to determine the availability of Small Businesses including, HUBZone, Service-Disabled Veteran-Owned Small Business Concerns and Small Disadvantage Businesses capable of performing Construction of a Medium Voltage Electrical Substation. The applicable North American Industry Classification System (NAICS) Code is 236220 (Commercial and Industrial Building Construction) and the small business size is $33.5 million. If it is determined that enough qualified small businesses exist to perform the work under this requirement, this acquisition will be set-aside for competition among small business participants. BACKGROUND: The NIH main campus is located in Bethesda, Maryland. As part of the U.S. Public Health Service under the Department of Health and Human Services, NIH is the Federal Government's primary biomedical research agency. Following is the description of NIH Bethesda /facilities where Electrical Substation contracts will be performed: NIH Main Campus, Bethesda, Maryland (306 acres, 60 buildings, over 5.5 million square feet of space) DESCRIPTION OF THE REQUIREMENT: The NIH anticipates awarding a fixed price contract under a single solicitation. The NIH seeks highly qualified credentialed contractors with capability to perform complex electrical infrastructure work including medium voltage electrical switchgears and substations. The selected contractor shall exhibit demonstrated experience, capability and resources enabling them to plan and construct projects of comparable size and complexity with comparable clients, and most significantly with demonstrated track record of performing such projects with a high degree of customer satisfaction. Selected contractor shall have enough remaining individual and aggregate bonding capacity to perform the contract. Contractors proposing to perform the contract as joint venture shall use the procedure described at the Small Business Administration (SBA) web site. The SBA URL is www.sba.gov, and the keyword search is Joint Venture and or Mentor Prot'g. Potential contractors shall have current information in the Central Contractor Registration (CCR) database. The CCR URL is www.ccr.gov. In accordance with FAR 4.1102 prospective contractors shall be registered in the CCR database pror to award of a contract. The selected contractors shall provide all labor, supervision, tools, materials, equipment, transportation, and management necessary or incidental to constructing the medium voltage electrical switchgears and substations, concrete structure buildings, green roof construction, and must exhibit demonstrated experience, capability and resources in projects of comparable size and complexity, with comparable clients, and most significantly, with a demonstrated track record of performing such projects with a high degree of customer satisfaction. The selected contractor shall be capable of controlling dust and flying debris, and protecting all adjacent areas as the work area will be performed near occupied space is most instances, and shall follow all NIH Fire and Safety Regulation and Procedures. All offerors submitting a proposal to the solicitation must be fully qualified and licensed and have qualified subcontractors as applicable. Failure to meet these qualifications may result in a determination of technical unacceptability. Utility shutdown once scheduled shall be strictly adhered to as continuity of utilities is imperative. DESCRIPTION OF WORK - CONSTRUCTION SERVICES: Construction of a free standing rectangular building; the building will have two levels - the main (first floor) level, where the switchgear equipment is located, and the accessible crawl space level below, into which the electrical conduits are coming from and leaving for incoming and outgoing feeder services. The building exterior envelope consists of full height insulated architectural precast concrete panels supported at grade by cast in place concrete foundation walls. The building structure consists of steel columns with concrete footings and steel beams supporting the main level floor and roof decks filled with concrete. The switchgear is supported by the floor structure and beams below extending over the service access area below. The building incorporates blast design requirements and designed with a green roof. This substation is a portion of a larger effort to remove loads from an existing substation and transferring loads to a newly built electrical substation. The new switchgear in this substation is designed to ultimately feed buildings within the planned serving area of this substation. The estimated price range for this requirement is between $5 million and $10 million. Contractor shall perform the work so as not to interfere with NIH day-to-day operations and shall coordinate any and all outage requirement with government. The selected contractors shall be responsible for, but not limited to the following services: a) Construction inspection and construction support. b) Testing services, including construction material testing, factory witness testing, and field investigation and testing. c) Commissioning. d) Project Management. e) Cost Analysis. f) Schedule Development. g) Coordination (permits, document reviews) with NIH, local, State and Federal offices h) Evaluation of compliance with relevant codes and regulations including compliance with relevant environmental codes and regulations. POTENTIAL SOURCES SHALL PROVIDE THE FOLLOWING INFORMATION IN THEIR RESPONSE: 1) Company name, address, phone number, primary contact(s), e-mail address, NAICS code(s), business size (i.e., small/large) and DUNS Number. 2) List firm's experience in work performed of similar type and scope to include projects in progress and completed projects within the past 5 years, completion dates, contract numbers, project titles, short project descriptions, dollar amounts (base amount & change order amounts), and owner points of contact with their current phone numbers. Indicate if you were a prime contractor or subcontractor, and if a subcontractor, provide the name and point of contact for the prime contractor. 3) Provide information on current work remaining and dollar amounts. Provide a table showing current projects in progress as indicated below: (a) Project Description (b) Contract Amount ($) (c) Remaining Work in Progress ($) (d) Percent Completed (%) 4) Include specialized experience and technical competence of firm; date and identify specific experience and qualification of personnel and record of working together as a team; identify past record of performance on contracts to include Government agencies. 5) Provide Statement of Capability. Potential sources' experience must demonstrate and document the following in the capability statements: (a) Ability to work on Critical Facilities Electrical projects. (b) Ability to perform the work described above. (c) Bonding Capacity; aggregate and individual. (d) Experience Modification Rating (EMR) for the proceeding 3 years (e) Self-performance capability (Small Business Contractor shall self perform at least 15% of each task order). Show which part of the work you will perform with your own employees. (f) Building Information Modeling (BIM) Capability Interested firms shall submit four (4) copes of their qualification statement addressing each of the areas cited above. Written capability statements shall be limited to 15 pages and shall be received by 1200 noon, EST on Thursday, March 24, 2011. Failure to submit qualification statements or to submit all information requested may result in your firm's business categories being considered not interested in this requirement. Inquiries shall be submitted via e-mail to Aaron Crawford at aaron.crawford@nih.gov, or Ms. Kimberly Goodwin at Kimberly.Goodwin@nih.gov or via mail/courier to the address indicated below. No collect calls will be accepted. FACSIMILE TRANSMISSIONS WILL NOT BE ACCEPTED. Submitted Capability Statements to: National Institutes of Health, Office of Acquisition, ORF, ATTN: Aaron Crawford, Building 13, Room 2E47 (Receptionist), 9000 Rockville Pike, Bethesda, MD 20892 This notice is for information and planning purposes only and does not commit the Government to award a contract now or in the future. THIS IS NOT A REQUEST FOR PROPOSALS. The Government does not intend to award a contract based on responses under this Market Survey. In addition, the Government will not contact firms that submitted capability statements or include them on a mailing list on any subsequent solicitation to this notice. All questions/inquiries shall be submitted in WRITING through email to Aaron Crawford, at aaron.crawford@nih.gov, or Kimberly Goodwin at Kimberly.Goodwin@nih.gov, or mailed to the following address: Office of Acquisition, ORF, ATTN: Aaron Crawford, Building 13, Room 2E48, 9000 Rockville Pike, Bethesda, MD 20892. Qualification Statements via e-mail or facsimile will not be accepted.

Find Active Opportunities Like This

Get AI-powered intelligence on the opportunities still open

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS