Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, November 11 at 2:00 PM ET

Register Free →

This Sources Sought opportunity from Department Of Veterans Affairs was posted on June 7, 2024. The submission period has ended. Browse the details below for market research, or find similar active opportunities.

CONTAINER SYSTEM FOR SURGICAL INSTRUMENTS

Closed
36C25524Q0428Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

Active Opportunities Like This One

General Info

NAICS

339113 - Surgical Appliance and Supplies Manufacturing

Place of Performance

Wichita, KS, 67218, USA

Set-Aside

SBA

Documents

1

Sources Sought Notice - Container System for Surgical Instruments (36C25524Q0428)

PDF, Low prioritysources-sought
Low

AI Contract Breakdown

Uniform Contract Format

Contract not broken down yet

CLEATUS splits the solicitation into Uniform Contract Format (UCF) sections: scope, pricing, deliverables, and evaluation criteria.

Timeline

1 update
PhaseClosed
Posted

Sources Sought

Notice updated

The notice description changed.

Response Deadline

Deadline has passed

Submission Closed

Find active opportunities like this

Get full access to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyDepartment Of Veterans Affairs → 255-NETWORK Contract Office 15 (36C255)
Contacts1 person available
OfficeLEAVENWORTH, KS, 66048, USA
Office AddressLEAVENWORTH, KS, 66048, USA

Full Description

Show more
STATEMENT OF REQUIREMENT FOR AESCULAP CONTAINERS VETERANS HEALTH ADMINISTRATION 1. INTRODUCTION This solicitation is to provide the Robert J. Dole VA Medical Center with new container system for surgical instrumentation. 2. BACKGROUND Currently the Wichita VAMC uses the Case Medical container system to house all their instruments for sterilization purposes. The current container system can only provide one mode of sterilization which is steam sterilization. The Aesculap container system can accommodate multiple forms of sterilization (i.e., Pre-vac Steam, Gravity, Low-Temp). 3. SCOPE OF WORK The contractor shall provide all necessary materials, hardware, and attachments to ensure the container system is fully functional and operational for use. Contractor shall be responsible for cleaning all work areas after completion of tasks. This includes, but is not limited to, removal of packaging and a clean sweep/mop of the area as required by work type. Contractor on-site visits shall be coordinated with the COR (or designee) before being scheduled or conducted. Contractor staff shall always be professional and shall take all necessary precautions to maintain a safe environment for the occupants. 4. SECURITY REQUIREMENTS The C&A requirements do not apply, and a Security Accreditation Package is not required. 5. HOURS OF WORK Normal hours of operation are Monday through Friday, 8:00 a.m. to 4:30 p.m. Central Standard Time, excluding Federal holidays. The Government hereby provides notice and Contractor hereby acknowledges receipt that Government personnel observe the listed days as holidays: New Year's Day January 1 Martin Luther King's Birthday Third Monday in January President's Birthday Third Monday in February Memorial Day Last Monday in May Juneteenth June 19 Independence Day July 4 Labor Day First Monday in September Columbus Day Second Monday in October Veterans Day November 11 Thanksgiving Day Fourth Thursday in November Christmas December 25th 6. SALIENT FEATURES Various sizes and lengths Color coded Face plates Color coded Tags Aluminum 7. TECHNICAL REQUIREMENTS Basket and Container Synchronization Space-saving basket design Basket flexibility Ergonomic basket handling Instrument security Quick set identification feature Enhanced drying system. Able to withstand multiple modes of sterilization settings 8. WARRANTY/MAINTENANCE SERVICE The warranty shall include all manufacturer recommended Preventive Maintenance procedures for its duration. The contractor shall provide at minimum a 3-year warranty. The warranty shall include the following: all parts and all accessories shall be covered under the manufacturer's warranty and shall include all parts and labor. The contractor shall provide documentation of all work completed (corrective maintenance, preventive maintenance, software updates, etc.) within 3 business days of completion to the contracting officer's representative or designee. The warranty period shall not begin until after the Dole VAMC COR or designee has accepted the products delivery, installation, and functionality. The contractor shall provide documentation of all work completed (corrective maintenance, preventive maintenance, etc.) within 3 business days of completion to the contracting officer's representative or designee.

More opportunities from Department Of Veterans Affairs → 255-NETWORK Contract Office 15 (36C255)

Same awarding agency

NAICS: 236220
New
Federal
Z2DA--657-27-103JB, FCA Replace Building 51 Roof, JB
Solicitation # 36C25527Q0044
The Department of Veterans Affairs, Network Contracting Office 15, is conducting market research through a Sources Sought Notice to determine the availability of qualified Service-Disabled Veteran-Owned Small Business (SDVOSB) firms for a construction project at the St. Louis Medical Center Jefferson Barracks. The project involves the replacement of the roof and associated components for Building 51, covering approximately 56,000 square feet. The scope includes installing a 70-mil thermoplastic polyolefin (TPO) roofing system, replacing four skylights, and updating the penthouse roof-access ladder to meet OSHA and VA safety standards. The estimated value of the resulting contract is between 2 million and 5 million dollars, with a required performance period of 222 calendar days from the Notice to Proceed. The project requires the contractor to manage work within an occupied 24/7 facility, necessitating a detailed phasing plan and strict adherence to infection control and HVAC-intake protection. Key technical requirements include providing a 20-year no-dollar-limit warranty, ensuring positive drainage to prevent standing water for more than 48 hours, and submitting as-built record drawings in searchable PDF and editable CAD formats. Interested firms must be registered in SAM.gov under NAICS code 236220 and provide a capability statement by November 9, 2026, including evidence of CVE certification, bonding capability, and a history of comparable work performed within the last five years.
Commercial and Institutional Building Construction

POSTED

about 17 hours ago

DEADLINE

in 10 days
View Details

Earlier notices in this NAICS code

Posted before this notice, open and closed

Find Active Opportunities Like This

Get AI-powered intelligence on the opportunities still open

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS