Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, November 11 at 2:00 PM ET

Register Free →

This Government Contract opportunity from Department Of Defense was posted on September 20, 2009. The submission period has ended. Browse the details below for market research, or find similar active opportunities.

CONVEX RECTAL TRANSDUCER

Awarded
N0016809RC04U01Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

Active Opportunities Like This One

NAICS: 334510
New
Federal
6515--ForeSite SS Tablet w/Pressure Mapping Sensor System
Solicitation # 36C24827Q0082
The Department of Veterans Affairs, through Network Contracting Office 8, is conducting market research via a Sources Sought Notice to identify authorized sources for the ForeSite SS Tablet Pressure Mapping System manufactured by ForeSite Medical. This effort is for acquisition planning purposes and is not a formal solicitation. The required system is intended for clinical pressure assessment and treatment and must include the tablet platform, pressure-mapping sensors, sensor packs, chargers, software licenses, cables, and all necessary accessories. Key functional requirements include real-time pressure analysis and visualization, patient data storage and reporting, wireless and wired connectivity, and portable battery-powered operation. All equipment must be new and include the manufacturer's standard warranty. Interested vendors must submit electronic responses in PDF or Word format by October 30, 2026. Submissions must include the company name, address, Unique Entity Identifier, point of contact, and business size or socioeconomic status, such as SDVOSB, VOSB, Small Business, or Large Business. Additionally, respondents must provide documentation proving they are authorized to distribute or resell the ForeSite system, an estimated delivery lead time, and confirmation regarding the new condition and warranty of the product. The place of performance is located in Tampa, Florida, under NAICS code 334510.
248-NETWORK Contract Office 8 (36C248)

POSTED

2 days ago

DEADLINE

in about 21 hours
NAICS: 334510
New
Federal
Ocular Scanner
Solicitation # W91CRB-26-AWSP-Scanner-Ultrasonic-Ocular-RPP
The Portfolio Acquisition Executive Maneuver Ground Project Manager Maneuver Medical Systems is soliciting prototype proposals for a Scanner Ultrasonic Ocular device under Other Transaction Authority pursuant to 10 U.S.C. 4022. The objective is to award two prototype agreements for the delivery and demonstration of FDA-approved commercial solutions that provide anatomical visualization and diagnostic imaging of the eye, specifically for the anterior and posterior segments. Awardees are required to deliver four prototype units within 45 to 60 days of award for operational and environmental testing conducted in accordance with MIL-STD-810H. The estimated period of performance is twelve months, with awards expected around the first quarter of fiscal year 2027. The procurement utilizes a comparative best-value methodology, prioritizing technical approach, performance compliance, reliability, schedule realism, and past performance over cost. Key requirements include Trade Agreements Act compliance, MIL-STD-130N marking for hardware, and the provision of ruggedized transport cases. Deliverables encompass the hardware units, comprehensive user and maintenance manuals, cybersecurity documentation, and on-site operator training. Proposals must be submitted as four separate PDF volumes via DoD SAFE or secure email by November 12, 2026. This action is a direct Other Transaction Agreement and is not subject to the Federal Acquisition Regulation or Defense Federal Acquisition Regulation Supplement.
W6QK Acc-Apg

POSTED

2 days ago

DEADLINE

in 14 days

AI Contract Overview

Show more

The National Naval Medical Center intends to award a sole source contract to B-K Medical Systems, Inc. for the procurement of specialized ultrasound equipment and accessories. This acquisition is necessary to ensure compatibility with existing B-K ultrasound systems currently in use at two Naval Medical Centers. The required supplies include convex rectal transducers, reusable and disposable biopsy kits, sterile biopsy attachments, balloon water stand-offs, O-rings, extension tubing, and cleaning brushes. Conducted under simplified acquisition procedures per FAR 13.5, this procurement is classified under NAICS code 334510. There are no set-aside restrictions for this requirement, and the government has determined that B-K Medical Systems, Inc. is the only source capable of providing the specific hardware and components needed for optimal lateral biopsies and image quality.

General Info

Contract Value

$29,106

NAICS

334510 - Electromedical and Electrotherapeutic Apparatus Manufacturing

Place of Performance

NNMC 8901 Wisconsin Ave Bldg 54 Bethesda, MD 20889, BETHESDA, MD, 20889, USA

Set-Aside

NONE

Award Issued Date

Documents

0

No documents available

Documents will appear here when they are available.

AI Contract Breakdown

Uniform Contract Format

No documents to break down

The breakdown needs solicitation documents. None were found from this contract's source.

Timeline

PhaseAwarded
Posted

Combined Synopsis

Awarded

Contract was awarded

Submission Closed

Find active opportunities like this

Get full access to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyDepartment Of Defense → Walter Reed National
Contacts1 person available
OfficeBETHESDA, MD, 20889-5600, USA
Office AddressBETHESDA, MD, 20889-5600, USA
Contacts
Latoya Clayton-Bullock

Full Description

Show more
The National Naval Medical Center intends to negotiate on a sole source basis (IAW FAR 13.5) with B-K Medical Systems, Inc., 250 Andover Street, Wilmington, MA 01887-1048, as the only source that can provide the B-K Medical ultrasound scanners and systems in conjunction with existing B-K ultrasounds at two Naval Medical Centers. Specifically, the contractor shall provide all of the following: 2EA 8808A CONVEX RECTAL TRANSDUCERS REALTIME SIMULTANEOUS IMAGINING FOR OPTIMAL LATERAL BIOPSIES MFI 5 10MHZ (5,6,8, & 10MHZ) FOR MAXIUM IMAGE QUALITY & PENETRATION 140 DEGREE FIELD OF VIEW FOR LARGER PROSTATE GLANDS DISPOSABLE BIOPSY GUIDES STERIS COMPATIBLE HC MDL 64575, 65624, 70586 CL3 2EA UA1257-R17E REUSABLE BIOPSY KIT FOR 8808 INCLUDES UA 1257- BIOPSYATTACHEMENT UC 5296-E-17G LONG NEEDLE GUIDE HC MDL 64575, 65624, 70586 CL3 2EA UA1257S17E STERILE DISPOSABLE BIOPSY ATTACHMENT FOR 8808 18 PER PACK HC MDL 79522 CL 2 2EA UA0799-1 BALLOON WATER STAND OFF'S (100PER PACK) 2EA UA0210 ORINGS FOR 8508 & 8808 HC MDL 64575 CL 3 2EA MS0402 EXTENSION TUBING FOR 8508/8808, 2050/52 HC MDEL 1752 CL 2 2EA PC-003 CLEANING BRUSHES FOR GUIDES UC5298 & US5299 & BIOPSY CHANNEL FOR 8551 3 PER PACK This acquisition is being conducted under simplified acquisition procedures (IAW FAR 13.5). There are no set-aside restrictions for this requirement. The intended procurement will be classified under North American Industry Classification System (NAICS) 334510 with a Small Business Size Standard of 500 employees. This notice of intent is not a request for competitive proposals and no solicitation document exists for this requirement. A determination by the Government not to compete based on responses to this notice is solely within the discretion of the Government. No phone calls accepted.

Earlier notices in this NAICS code

Posted before this notice, open and closed

Find Active Opportunities Like This

Get AI-powered intelligence on the opportunities still open

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS