Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, November 11 at 2:00 PM ET

Register Free →

This Sources Sought opportunity from Department Of Agriculture was posted on May 2, 2023. The submission period has ended. Browse the details below for market research, or find similar active opportunities.

Core-Chillers Preventative Maintenance - Sources Sought

Closed
12505B23Q0106SSFederal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

Active Opportunities Like This One

NAICS: 811310
New
Kubota M8200 Clutch Replacement
Solicitation # kubota-m8200-clutch-replacement
Management & Training Corporation (MTC) is soliciting bids for the clutch replacement of a Kubota M8200 tractor with front wheel assist, no cab or loader, located at the Earle C. Clements Job Corps Center in Morganfield, Kentucky. The scope of work requires the contractor to provide all transportation, labor, supervision, tools, and new manufacturer-specified parts to diagnose and repair the clutch assembly and power take-off (PTO) system. Key technical requirements include disassembling tractor components, replacing friction discs, bearings, oil seals, and O-rings, resurfacing the flywheel, and replacing hydraulic pipes and filters as necessary. The project is complete once the Facility Maintenance Department verifies proper clutch engagement and PTO operation under load. This is a small business set-aside opportunity under NAICS code 811310, open to various SBA-certified categories including VOSB, SDVOSB, WOSB, and HUBZone businesses. Proposals must be submitted via email to Angie Mahoney by November 3, 2026, and must include a lump sum bid sheet, a completed supplier packet with a W-9 and self-certification form, and proof of insurance. Award will be based on best value, considering the contractor's qualifications, experience, and the itemized cost breakdown. The contract is subject to Federal Acquisition Regulation (FAR) clauses regarding the Buy American Act, combating trafficking in persons, and Service Contract Labor Standards per Wage Determination No. 2015-4687 Revision 31 for Kentucky.
Earle C. Clements Job Corps Center

POSTED

about 4 hours ago

DEADLINE

in 5 days
NAICS: 811310
New
SLED
**Certified SB/DVBE Only** IFPQ Boiler Inspection, Maintenance, Repair, Testing, and Reporting in Los Angeles County
Solicitation # 07A6539
The California Department of Transportation (Caltrans) is soliciting price quotes for an Invitation for Price Quote (IFPQ 07A6539) to provide comprehensive boiler inspection, maintenance, repair, testing, and reporting services at the District 7 Office facility in Los Angeles, California. The scope of work includes annual and quarterly preventative maintenance for three Unilux water tube boilers and six boiler pumps, ensuring compliance with manufacturer standards, ASME Code, OSHA requirements, and South Coast Air Quality Management District standards. This is a set-aside solicitation exclusively for certified Small Business (SB), Microbusiness (MB), or Disabled Veteran Business Enterprise (DVBE) entities. The contract will be awarded to the responsible bidder offering the lowest price quote who meets all specifications. Key operational requirements include a 48-hour response time for routine service requests and a strict prohibition on subcontracting any portion of the work. The contractor must adhere to State General Prevailing Wage Rates for Los Angeles County and provide a payment bond for any service request exceeding 25,000 dollars. Required submission documents include a Price Quote Proposal, Bidder Certification Sheet, Non-Collusion Declaration, and certifications for California Civil Rights Laws and the Darfur Contracting Act. Invoicing is conducted monthly in arrears and must be accompanied by certified payroll records and DVBE utilization reports. The agreement is subject to a budget contingency clause, meaning it is enforceable only if sufficient funds are provided by the California State Legislature or the United States Government.
California Department of Transportation

POSTED

about 5 hours ago

DEADLINE

in 15 days
NAICS: 811310
New
SLED
RFP 07-135 Roseville Electric Utility – Air Compressor Maintenance
Solicitation # 07-135
The City of Roseville is soliciting proposals under RFP 07-135 for a consultant to provide comprehensive scheduled preventive and corrective maintenance for air compressors and auxiliary systems, including Ingersoll Rand equipment. The services will be performed at the Roseville Energy Park and Sunset Energy Center in California. The selected consultant will be responsible for providing all necessary labor, technical expertise, specialized tooling, and materials. This is a prevailing wage project with an initial contract duration of five years, estimated to commence in April or May. Proposals must be submitted by December 16, 2026, via email to the City Clerk or through physical delivery in a sealed container with the required Attachment H label. The award will be based on a formal evaluation panel process considering the firm's experience and qualifications (25 points), the proposed project plan (35 points), and cost (40 points), with potential interviews for top candidates. Requirements for the successful bidder include obtaining a City of Roseville business license, providing 100% faithful performance and labor and materials bonds, and maintaining specific insurance policies. Consultants must also disclose any conflicts of interest and adhere to the Levine Act regarding political contributions.
City of Roseville

POSTED

about 10 hours ago

DEADLINE

in about 2 months

General Info

NAICS

811310 - Commercial and Industrial Machinery and Equipment (except Automotive and Electronic) Repair and Maintenance

Place of Performance

Madison, WI, 53706, USA

Set-Aside

NONE

Documents

1

Sources Sought Response Form

PDF, Low prioritysources-sought
Low

AI Contract Breakdown

Uniform Contract Format

Contract not broken down yet

CLEATUS splits the solicitation into Uniform Contract Format (UCF) sections: scope, pricing, deliverables, and evaluation criteria.

Timeline

PhaseClosed
Posted

Sources Sought

Response Deadline

Deadline has passed

Submission Closed

Find active opportunities like this

Get full access to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyDepartment Of Agriculture → USDA Ars Mwa Aao Acq/per Prop
Contacts1 person available
OfficePEORIA, IL, 61604, USA
Office AddressPEORIA, IL, 61604, USA
Contacts

Full Description

Show more
A market survey is being conducted to determine if there are adequate Small Businesses, Disadvantaged Small Businesses, SBA-certified 8(a) Program Participants, SBA-certified HUB Zone Businesses, Veteran-Owned Small Businesses (VOSB), Service Disabled Veteran Owned Small Businesses (SDVOSB), Women-Owned Small Businesses, AND/OR Economically Disadvantaged Woman Owned Small Businesses (EDWOSB) contractors available for a proposed project who meet the specific criteria outlined below. This is a SOURCES SOUGHT NOTICE ONLY. This is NOT a solicitation Announcement, Request for Quote (RFQ), Request for Proposal (RFP), or Request for Bids (RFB). It does NOT constitute any commitment by the Government. NO award will result from this notice. The purpose is to conduct market research to gain knowledge of potentially qualified sources and to determine the capability of Small Business and/or Large Business companies to provide the supplies/services described below. Responses to this Sources Sought Notice will be used by the Government to make an appropriate acquisition decision. Department of Agriculture (ARS) requests responses from ALL socioeconomic categories in order to gain a more complete understanding of the market for these products and service. The United Stated Department of Agriculture, Agricultural Research Services (USDA-ARS) will NOT award a contract on the basis of responses OR pay for the preparation of any information submitted. Respondents will NOT be notified of the results of this notice. After completing an analysis of the responses, the Government will determine whether to limit competition to 8(a), HUBZone, Disadvantaged, VOSB, SDVOSB, Women-Owned, EDWOSB, or other small business firms, to proceed with issuing an unrestricted solicitation (inviting full and open competition), OR make a sole source award. The NAICS code for the expected acquisition is 811310 (Commercial and Industrial Machinery and Equipment (except Automotive and Electronic) Repair and Maintenance) with a Size Standard of $12.5 Million and the PSC Code is J041. Any subsequent procurement will be conducted as a commercial item purchased in accordance with FAR Part 12 and as a Simplified Acquisition Procedure in accordance with FAR Part 13. The United Stated Department of Agriculture, Agricultural Research Services (USDA-ARS) has the need for the following service: 001) Core-Chillers Preventative Maintenance Scope: The USDA-ARS Midwest Area (MWA) Administrative Office's Acquisitions & Personal Property/Fleet Team on behalf of the USDA-ARS Dairy Forage Research Center located at 1925 Linden Dr, Madison, WI 53706 is seeking sources that can provide preventative maintenance for two main chillers. Background: The two chiller units, as well as the air handler, are Carrier manufactured equipment and represent a large financial investment for the DFRC-Madison facility. Preventative maintenance is essential to extend the life of these units economically and minimize downtime. Technical Requirements: Unit: 19XRV2020225BES64; Serial Number: 0411Q20382; Description: Water-Cooled Chiller 19XRV. Unit: 30HXC096R-661KA; Serial Number: 0311Q18854; Description: Water-Cooled Chiller High Pressure. Operating Inspection: Technician will observe the unit in operation. Noting any unusual noises and vibrations, leaking refrigerant, oil, or water. Technician will check unit operating parameters such as temperatures, refrigeration pressures, oil pressure, inlet and discharge water temperatures (from the tower) discharge water temp control point, (approximately 44'F). The technician will review alarm faults on the unit control panel and make recommendations for repair or adjustment based on their findings and observations. Annual Preventative Maintenance/Seasonal Startup: Technician will review alarm faults on unit control panel, perform oil and filter changes as required (due to operating hours or oil analysis findings). Checking refrigerant charge as required from operating history (reviewed on the unit control panel). Vibration Analysis: Technician will install vibration test points on the unit. Annually the technician will connect to vibration monitor and record the unit's vibration while it is in operation. This information over time will develop a trend and show different issues developing within the unit, (for example, worn bearings). The use of the vibration analysis allows for the developing issues to be identified early and avoid major failures. Condenser Tube Cleaning: Over time sediment and hard water deposits from cooling water from the tower will build up in the tubes of the heat exchanger located at each unit. With this happens water temperatures and pressure will rise across the heat exchanger making the unit less efficient. Technician will come in remove the inlet and discharge piping from the heat exchanger, remove each end bell from the heat exchanger and clean using a heat exchanger tube cleaner each on the tubes within the tube bundle (heat exchanger). Technician will conduct an inspection of the tubes to ensure all tubes are clean and in good condition (no damage such as holes worn into the tubing). Once the tubes are clean and inspected Technician will reinstall the end bells using new gaskets and following manufactured technical instructions. Technician will reinstall all inlet and discharge piping and restart the system to ensure normal operating parameters are met and no leakage from the pipe connections and end bell connections. Oil Analysis: Technician annually (minimum) will take a sample of the operating oil and send to laboratory for analysis. The analysis will show the presence of contaminating particulates in the oil. These particulates will show wear of various parts of the unit. Examples being bearings, piston rings, and seals. As with the vibration analysis over time this helps develop trends showing the wear of the unit allowing repairs to be made, or planned replacement of the unit, before major causalities occur. SMART Service: Electronic monitoring of the system that allows the vendor to monitor operations and alarms of the system. If there is an alarm the vendor will inform the operator. Travel: The vendor will need to travel to the USDA-ARS Dairy Forage Research Center located at 1925 Linden Drive, Madison, WI 5370 to service the units. Security Requirements: The work will take place at the DFRC-Madison building. The contractor does not require a security clearance to complete the work. Deliverables and Delivery Schedule: Operating Inspection; Yearly Annual PM; Yearly Vibration Analysis; Yearly Seasonal Startup; Yearly Condenser Tube Cleaning; Yearly Oil Analysis; Yearly (Minimum) SMART Service; As Required Capability Statement: Companies who have the experience, as well as an interest in doing business with the USDA-ARS, plus those that can provide technically acceptable products should submit a Capabilities Statement which, for this notice, is NOT a quote, proposal, or bid, but rather short statements regarding the company's ability to demonstrate their expertise and experience in relation to the areas specified in this notice. In addition to the Capabilities Statement, companies should complete the - Sources Sought Response Form included in the attachments section of this notice and indicate whether they are a Small Business Concern, Disadvantaged, SBA-certified 8(a) Program Participant, SBA-certified HUB Zone Business, Veteran-Owned, Service Disabled Veteran Owned, Women-Owned, Economically Disadvantaged Woman Owned, Large Business, OR a Foreign Business. To be eligible, all vendors must be registered in the System for Award Management (SAM) with a current and active registration. A Unique Entity Identifier (UEI) number is required in order to register in SAM. A vendor can contact SAM by calling +1 (555) 000-0000 or e-mail at www.sam.gov. NO EXCEPTIONS. Vendor must include their UEI# on their capability statements. To be eligible, all vendors must also be registered in SAM under the specific NAICS code listed as part of this sources sought or qualify as a small business under the listed NAICS code. If a prospective vendor is NOT registered under the specified NAICS code and would qualify to be registered under it then they should update their SAM registration prior to providing a capabilities statement. Finally, to be eligible, all vendors must be NDAA 889 Certified. Contractors will represent that: It will NOT provide covered telecommunications equipment or services to the Government in the performance of any contract, subcontract or other contractual instrument resulting from this solicitation. After conducting a reasonable inquiry, for purposes of this representation, the Offeror represents that it does NOT use covered telecommunications equipment or services, or use any equipment, system, or service that uses covered telecommunications equipment or services. Submitting a Capability Statements: Questions in regards to this Sources Sought must be submitted through email to contact@example.gov by no later than Thursday, May 4, 2023 at 11:59 PM CT. Telephone inquiries will NOT be accepted. Responses (capability statement AND a sources sought response form) should be submitted via email to contact@example.gov by no later than Tuesday, May 9, 2023 at 11:59 PM Central Time (CT). The e-mail subject line, body, or attachments MUST include: - Core-Chillers Preventative Maintenance - Sources Sought and/or - 12505B23Q0106SS. Disclaimer: This notice does NOT obligate the Government to award a contract or otherwise pay for the information provided in response. The Government reserves the right to use information provided by respondents for any purpose deemed necessary and legally appropriate. Respondents are also advised that under NO obligation to acknowledge receipt of information or provide feedback about any of the information received. After review of the responses received, the Government MAY issue a combined synopsis and solicitation. NO proprietary, sensitive, confidential or classified information shall be included with your response. The Government reserves the right to use any non-proprietary technical information in any resultant solicitation.

Earlier notices in this NAICS code

Posted before this notice, open and closed

Find Active Opportunities Like This

Get AI-powered intelligence on the opportunities still open

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS