Show more

This sources sought notice is issued by the Department of Defense to identify potential suppliers of crane parts and components for the repair and upgrade of Heyl-Patterson 10,000 lb capacity cranes at Naval Submarine Base Kings Bay. The agency is specifically seeking information on the availability of compatible alternatives to brand-name components, including Magnetek pre-engineered control panels, Magnetek SBP2-8 electromotive pendants, and Rueland VFD inverter rated motors with B gear reducers. All parts must comply with the NAVFAC P-307 Weight Handling Program Management requirements. The primary objective is to determine if generic or alternative brand components can be used instead of the specified name brands to ensure full crane functionality. Interested parties must submit their responses by September 1, 2026, detailing their experience with non-name brand components for these specific cranes or providing justification for adhering to the original brand specifications. This is a market research effort and does not constitute a request for quotes or a formal solicitation.

General Info

DoD seeks suppliers of compatible crane parts for Naval Submarine Base Kings Bay.

Agency

Department Of Defense → Navfacsyscom SoutheastView Agency

NAICS

333923 - Overhead Traveling Crane, Hoist, and Monorail System ManufacturingView NAICS

Place of Performance

Kings Bay, GA, 31547, USA

Set-Aside

NONE

Documents

(0)

No documents available

AI Contract Breakdown

Uniform Contract Format

No contract breakdown available.

Cannot generate Contract Breakdown because no documents were found from this contract's source.

Timeline

PhaseSources Sought
Posted

Sources Sought

Response Deadline

Submission deadline

Response Deadline

Ready to pursue this opportunity?

Start your free trial to track this contract, build proposals with AI assistance, and manage your pipeline.

Organization & Contact Information

Show more
AgencyDepartment Of Defense → Navfacsyscom Southeast
Contacts1 person available
OfficeNAS JACKSONVILLE, FL, 32212-0030, USA
Organization / Agency
Department Of Defense → Navfacsyscom Southeast
View Agency Profile
Office AddressNAS JACKSONVILLE, FL, 32212-0030, USA
Contacts

Full Description

Show more

THIS NOTICE DOES NOT CONSTITUTE A REQUEST FOR EITHER A QUOTE OR PROPOSAL, OR AN INVITATION FOR BID.THE INTENT OF THIS SOURCES SOUGHT IS TO IDENTIFY POTENTIAL CRANE PARTS AND COMPONENTS CAPABLE OF MEETING THE AGENCY’S REQUIREMENTS. NO SOLICITATION, SPECIFICATIONS OR DRAWINGS ARE CURRENTLY AVAILABLE.



The purpose of this notice is to determine if there are commercially available crane parts and components that demonstrate the ability to meet the Agency’s requirements. The crane parts and components would potentially be specified (as brand name) issued for services to repair or upgrade cranes located at Naval Submarine Base Kings Bay within the NAVFAC Southeast Area of Responsibility.
 


Looking for parts which have capability with Heyl-Patterson 10,000 lb. capacity cranes 83-00330 and 83-00331 These parts must comply with the requirements of the NAVFAC P-307 Weight Handling Program Management for compatible maintenance and replacement parts for this type of crane.  Required parts are as follows:



  • Magnetek Pre-Engineered Control Panel (141-27330):
    • 4014 G+ Series 4 Drive w/Line and Load Reactors, DB Resistor, CB (hoist)
      • Meeting: 460V AC, 7.5 HP (Heavy Duty) VFD with line and load reactors, DB resistor, CB for the hoist
    • 4001 G+ Series 4 Drive w/Line and Load Reactors, DB Resistor, CB (trolley)
      • Meeting: 460V AC, 0.75 HP (Heavy Duty) VFD with line and load reactors, DB resistor, CB for the trolley
    • 4003 G+ Series 4 Drive w/Line and Load Reactors, DB Resistor, CB (bridge)
      • Meeting: 460V AC, 2 HP (Heavy Duty) VFD with line and load reactors, DB resistor, CB for the bridge
  • Magnetek SBP2-8 Electromotive Pendant (127-24279)
  • Rueland VFD Inverter Rated Motor With "B" Gear Reducer (0007C-XBAC-XXXX-TBA)


This sources sought is seeking responses to determine whether or not there are compatible parts which could replace the parts as listed above (Magnetek and Rueland) which could be used to ensure full functionality of the Heyl-Patterson 10,000 lb capacity cranes. If generic parts may be used instead of the name brand then it is the government’s intent not to restrict the purchase to name brand only. If there is no other compatible part, then the government’s intent will be to solicit based on a single source (brand name) for crane parts and components. The intent is to use these parts for the purpose of upgrading the cranes.



Responses to this inquiry are to be submitted by 01 September 2026. Responses should include the following:


  1. Have you used non-name brand/different name brand components to accommodate the maintenance/repair of these same Heyl-Patterson 10,000 lb capacity cranes? If you have, please describe the brand/type and any obstacles/successes.
  2. If your recommendation is to stay with the brand name parts as specified above and by the NAVFAC P-307 Weight Handling Program Management, please provide your reasoning.


If no responses are received by 12:00 PM EDT, 01 September 2026, to the effect that obtaining compatible parts then the Government will proceed with obtaining these parts through utilization of the name brand as identified. As the sole intent of this sources sought is for market research and to determine the utilization of name brand for these cranes, there will not be an opportunity for the government to respond to industry inquiries.



Please provide your responses via electronic form to the following email address: jessica.l.baynocky.civ@us.navy.mil


Any attachments provided should be in PDF format and are limited to 5 pages maximum in length, 5MB in size. These responses should only include the information requested in this announcement. Please identify in the subject line of your email: "Crane Upgrade Parts Sources Sought".



We appreciate your assistance to the Naval Facilities Engineering Command in obtaining this information.



NO REIMBURSEMENT WILL BE MADE FOR ANY COSTS ASSOCIATED WITH PROVIDING INFORMATION IN RESPONSE TO THIS ANNOUNCEMENT OR ANY FOLLOW-UP INFORMATION REQUESTS. IN ORDER TO PROTECT THE PROCUREMENT INTEGRITY OF ANY FUTURE PROCUREMENT, IF ANY, THAT MAY ARISE FROM THIS ANNOUNCEMENT, INFORMATION REGARDING THE TECHNICAL POINT OF CONTACT WILL NOT BE PROVIDED.

Similar Contracts

Same NAICS industry code

NAICS: 333923
New
Federal
15-Ton Bridge Crane
Solicitation # N4523A26Q0202
The Puget Sound Naval Shipyard and Intermediate Maintenance Facility is conducting market research to identify capable vendors for the procurement, design, shop testing, and installation of a new 15-ton bridge crane at the TRF-Bangor location, along with the complete breakdown, removal, and scrapping of the existing crane. The requirement must comply with NAVFAC P-307 standards, and detailed specifications are outlined in the attached Statement of Work. The government anticipates all work to be completed by the third quarter of fiscal year 2028 and is considering whether to set aside the contract for small businesses or pursue full and open competition, with a single award anticipated. The NAICS code is 333923 with a small business size standard of 1,250 employees, and the product service code is 3950. Businesses of all sizes are encouraged to respond, though no formal solicitation has been issued and this notice does not constitute a commitment or guarantee of future procurement. Responses must include the organization’s name, CAGE code, and Unique Entity ID number, and may include supporting capability materials. Submissions are to be sent via email with the subject line “Sources Sought Response for N4523A26Q0202” to the designated government contacts before the deadline of August 11, 2026. All information submitted will be treated as voluntary and proprietary, protected from external release, and will not be returned. No funding is available for response preparation, and failure to respond does not preclude future participation in an official solicitation, which will be posted on the Government-Wide Point of Entry if issued. The government will not provide evaluations or feedback on responses, which will be used solely for planning and procurement strategy development.
Puget Sound Naval Shipyard IMF

POSTED

2 days ago

DEADLINE

in 14 days
View Details
NAICS: 333923
New
Federal
5 Ton Bridge Crane
Solicitation # W911KF26QA049
The Army Contracting Command-Detroit, Anniston Army Depot, has issued solicitation W911KF26QA049 for the procurement and installation of one 5-ton top-running, single-girder bridge crane in Building 129 at the Anniston Army Depot in Alabama. This fixed-price requirement is a Small Business Set-Aside under NAICS code 333923 and is intended to replace an existing unit used to support the 850-transmission test stand. The contractor is responsible for the design, construction, and installation of a safety yellow crane that meets CMAA moderate service requirements and complies with OSHA, ANSI, NFPA, NEC, and AWS standards. Key deliverables include the physical crane system and comprehensive documentation, consisting of four printed and one electronic copy of all operator manuals, maintenance manuals, and spare parts lists. The government will utilize a Lowest Price Technically Acceptable (LPTA) source selection process, evaluating proposals on a met/not met basis regarding technical requirements and the lowest evaluated price. Bidders must submit technical literature demonstrating compliance with all specifications; failure to provide this documentation will result in a determination of unacceptable. The installation must be completed and the equipment operational within 60 calendar days of the work commencement. Contractors must be registered in the System for Award Management (SAM), submit proposals electronically via the Procurement Integrated Enterprise Environment (PIEE), and adhere to strict safety and security protocols, including Anti-Terrorism Level I training and the provision of site-specific safety plans. All items must meet specific marking and identification standards, including Unique Item Identification (UID) and manufacturer nameplates.
W6QK Acc Anad

POSTED

6 days ago

DEADLINE

in 8 days
View Details

More opportunities from Department Of Defense → Navfacsyscom Southeast

Same awarding agency

NAICS: 238220
Federal
Critical HVAC/DDC Maintenance Services - The Contractor shall provide personnel with the qualifications, technical knowledge, experience and skills required for efficient operation, maintenance and repair within the SRM function.
Solicitation # N6945026RHVAC
This Request for Information (RFI) seeks to identify qualified U.S. Small Business Administration certified 8(a) business development program participants to provide Heating Ventilation and Air Conditioning (HVAC) and Direct Digital Controls (DDC) services at Naval Air Station (NAS) Jacksonville, Florida. The scope of work includes maintenance, repair, minor construction, and demolition for building systems, boilers, and other assets to ensure full life expectancy and operational efficiency. The government is considering various procurement methods, such as single award or combination firm fixed price/IDIQ contracts, with an estimated maximum contract value ranging from $200,000 to $4,500,000. Interested contractors must possess specific technical qualifications, including Cybersecurity Maturity Model Certification and various state and federal certifications. Key personnel requirements include at least two Journeyman-certified HVAC technicians, a full-time safety leader with 30-hour OSHA certification, and specialized factory-trained Trane Summit Controls personnel. All service personnel must have completed 10-hour OSHA safety training and meet specific EPA, NAVFAC, and Florida state licensing standards for mechanical, plumbing, and electrical work. Responses must be submitted via email in PDF format, including a capability statement and the completed RFI questionnaire, no later than 5:00 PM ET on August 28, 2026.
Plumbing, Heating, and Air-Conditioning Contractors

POSTED

28 days ago

DEADLINE

in 2 days
View Details