Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, October 28 at 2:00 PM ET

Register Free →

Digital Voltage Regulator, Cooper Nuclear Station

Active
Request for Bid (RFB) No. 26086State & Local

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

AI Contract Overview

Show more

Nebraska Public Power District is soliciting bids under RFB No. 26086 for the design, manufacture, delivery, and installation of a complete digital voltage regulator and power system stabilizer for the uprated synchronous Main Generator at the Cooper Nuclear Station near Brownville, Nebraska. The project aims to improve the plant capacity factor and reduce future corrective maintenance costs by implementing a more reliable, fault-tolerant system while minimizing impacts on Main Control Room operator controls. The scope includes all necessary labor, technical support, software, and supplies, with a specific requirement for forty hours of onsite technical start-up support. Bids are due by January 14, 2027, and must be submitted via email to the designated procurement specialists. The contract will be awarded to the responsible bidder offering the lowest and best bid based on factors including price, technical conformance, schedule capability, and past performance. Key requirements include adherence to a fifteen-day installation window aligned with the station outage schedule and compliance with the prevailing wage standards for Nemaha County to satisfy Internal Revenue Code section 45U(d) bonus credit eligibility. Technical specifications mandate a 72-hour burn-in run for all equipment, factory testing per ANSI and NEMA standards, and strict cyber security protections, including tamper-evident mechanisms for critical digital assets. Additionally, the contractor must comply with FCC Covered List prohibitions and provide seismic certification and equipment anchorage details.

General Info

Bids for digital voltage regulator and power system stabilizer at Cooper Nuclear Station.

NAICS

N/A

Place of Performance

NE, USA

Set-Aside

NONE

Documents

2

RFB No. 26086 - Bid Document

DOCX, High priority: read this firstrfb
High

RFB No. 26086 - Pre-Bid Microsoft Team Meeting Information

DOCX, Low priorityindustry-day
Low

AI Contract Breakdown

Uniform Contract Format

Sign up to view the full breakdown with detailed analysis of each section.

Timeline

PhaseSolicitation
Posted

Solicitation

Response Deadline

Submission deadline

Response Deadline

Ready to pursue this opportunity?

Start your free trial to track this contract, build proposals with AI assistance, and manage your pipeline.

Organization & Contact Information

Show more
AgencyNebraska Public Power District
Contacts1 person available
OfficeNE, USA
Organization / AgencyNebraska Public Power District
Office AddressNE, USA
Contacts
Contact for questions Bill RuskampSenior Procurement Specialist Ph: E-mail:

Full Description

Show more
Return to Bid List Bid NUMBER Request for Bid (RFB) No. 26086 TITLE Digital Voltage Regulator, Cooper Nuclear Station PROCESS Offline BASE CURRENCY USD STATUS Open for Bidding CLOSES IN 78 days: 23 hours: 6 minutes: 2 seconds DESCRIPTION BID DOCUMENTS BIDDERS CALENDAR NUMBER Request for Bid (RFB) No. 26086 TITLE Digital Voltage Regulator, Cooper Nuclear Station AVAILABLE DATE 10/27/2026 5:40 PM DUE DATE 1/14/2027 4:00 PM CONTACT INFORMATION Contact for questions: Bill Ruskamp, Senior Procurement Specialist Ph: +1 (555) 000-0000 E-mail: contact@example.gov
BID TYPE Request for Bid DESCRIPTION
Nebraska Public Power District (DISTRICT) intends to procure all design, manufacture, labor, technical support, specialty tools (if any), equipment, material, software and supplies for the delivery and installation of a complete digital voltage regulator (DVR), power system stabilizer, and any other technical data to supply the volt-ampere requirements of the main field of the uprated synchronous Main Generator at Cooper Nuclear Station (CNS) near Brownville, Nebraska.
Details regarding this project can be found under the "Documents" tab.
PRE-BID MEETING? Yes - Optional PRE-BID MEETING DATE AND TIME 11/17/2026 10:00 AM PRE-BID MEETING DETAILS Information to join the non-mandatory pre-bid Microsoft Teams meeting can be found under the "Documents" tab.
A non-mandatory pre-bid teleconference for prospective Bidders will be held on November 17, 2026, at 10:00 a.m., CST. The purpose of the teleconference will be to review the Contract specifications and to answer any questions or clarifications the Bidder may have concerning the Contract requirements. It is the Bidder’s responsibility, while participating on the teleconference, to ask any questions necessary to understand the requirements of the Contract so the Bidder can submit a bid that is complete and according to the specifications. It is highly encouraged that all prospective Bidders participate in this teleconference. If you plan to participate in the pre-bid teleconference, call in information can be found on the ProcureWare website at www.nppd.com under Bids & Contracts.
Please indicate your company's intent to bid.
Undecided No Bid Will Bid Notes Submit Intent BID CATEGORIES (1 record) CODE TITLE FULL NAME V600 Voltage Regulators V600 Voltage Regulators

More opportunities from Nebraska Public Power District

Same awarding agency

Ready to Pursue This Opportunity?

Get AI-powered intelligence on this solicitation and the ones like it

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS