Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, October 28 at 2:00 PM ET

Register Free →

This Combined Synopsis/Solicitation opportunity from Department Of Defense was posted on February 25, 2016. The submission period has ended. Browse the details below for market research, or find similar active opportunities.

East Shaft Pumping Station Rehabilitation, Washington Aqueduct Division,

Closed
W912DR-16-B-0006Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

Active Opportunities Like This One

NAICS: 237110
New
Morgans Branch Force Main and Pump Station Improvements
Solicitation # SRP-W-134-0290
The Morgans Branch Force Main and Pump Station Improvements project, solicitation number SRP-W-134-0290, is a construction contract for the City of Belmont, North Carolina, with an estimated value of 16,690,000 dollars. The scope of work involves the construction of 16,435 linear feet of new 20-inch ductile iron force main and comprehensive upgrades to the Morgans Branch Pumping Station. Key infrastructure improvements include the installation of a new wet well, valve vault, and associated appurtenances, as well as the demolition of existing pumps and piping. The contractor is responsible for delivering a fully operational facility, including the installation of pumps, a generator, odor control equipment, new gravity sewers, and manholes, while managing by-pass pumping, testing, and commissioning. The contract will be awarded to the responsible bidder submitting the lowest responsive bid, with a strong emphasis on MWBE compliance through the submission of Good Faith Efforts and Table A documentation. Bids are due by November 12, 2026, and must be submitted using the EJCDC C-410 Bid Form. The project is governed by EJCDC standard general and supplementary conditions, requiring performance and payment bonds and proof of insurance. Technical standards include AWWA Specification C-600 for pipelines, NEMA MG1 for motors, and AWS D1.2 for aluminum welding. Project administration is managed by the City of Belmont with Willis Engineers serving as the project engineer. Payment is processed via Applications for Payment, with terms set at 30 days after presentation to the owner.
Don Moorhead Construction, Inc.

POSTED

about 12 hours ago

DEADLINE

in 20 days

General Info

Contract Value

$6,577,199

NAICS

237110 - Water and Sewer Line and Related Structures Construction

Place of Performance

McMillan Water Treatment Plant, 2500 First Street, NW, WASHINGTON, DC, 20001, USA

Set-Aside

NONE

Award Issued Date

Documents

2

Abstract_of_Bids_East_Shaft_Pumping_Station.pdf

PDF

REVISED_Abstract_of_Bids.pdf

PDF

AI Contract Breakdown

Uniform Contract Format

Contract not broken down yet

CLEATUS splits the solicitation into Uniform Contract Format (UCF) sections: scope, pricing, deliverables, and evaluation criteria.

Timeline

6 updates
PhaseClosed
Posted

Sources Sought

Type Changed

Sources Sought → Presolicitation

Type Changed

Presolicitation → Combined Synopsis

Notice updated

The notice description changed.

Notice updated

Notice details unchanged. Attachments may have changed.

Notice updated

Notice details unchanged. Attachments may have changed.

Response Deadline

Deadline has passed

Notice updated

Notice details unchanged. Attachments may have changed.

Notice updated

Notice details unchanged. Attachments may have changed.

Notice updated

Notice details unchanged. Attachments may have changed.

Submission Closed

Find active opportunities like this

Start your free trial to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyDepartment Of Defense → W2SD Endist Baltimore
Contacts1 person available
OfficeBALTIMORE, MD, 21201-2526, USA
Office AddressBALTIMORE, MD, 21201-2526, USA
Contacts
Stephen A Stolte

Full Description

Show more
This is a Sources Sought Notice and is for informational/ market research purposes only. THIS IS NOT A REQUEST FOR PROPOSALS, QUOTATIONS, OR BIDS. The U.S. Army Corps of Engineers, Baltimore District, requests capability statements from qualified Small Business (SB), Small Disadvantaged Business (SDB), Service Disabled Veteran Owned SB (SDVOSB), Veteran-Owned Small Business (VOSB), Historically or Underutilized Business Zones (HUBZones), small businesses concerning the potential project described below. Responses to this sources sought announcement will be used by the Government to make appropriate acquisition decisions. NO SOLICITATION IS CURRENTLY AVAILABLE. Responses are to be sent via email to Stephen.a.stolte@usace.army.mil no later than 1:00 p.m. eastern standard time November 24, 2015. Project Description: East Shaft Pumping Station Rehabilitation, Washington Aqueduct Division, Washington, DC. The solicitation will be for a construction contract and it will be advertized as an invitation for bid (IFB) in the $5M - $10M range. The work includes civil, structural, mechanical and electrical improvements to the East Shaft Pumping Station to increase its reliability and improve its function. Specific work items include removal of the existing East Shaft pump and installing a replacement submersible pump. Construction of structural floor & wall modifications, replacement of existing electrical transformers & switchgear, SCADA modifications and replacement of traveling screens. The Washington Aqueduct (WA) provides portable water to approximately one million people in the District of Columbia and Northern Virginia. The East Shaft Pumping Station is the point of entry for water to the McMillan Water Treatment Plant (WTP) which handles and treats about 40% of the Washington Aqueduct's entire production. The project will provide a comprehensive rehabilitation to the East Shaft Pumping Station. The McMillan WTP is a critical component of the distribution system and so careful consideration has to be given to the phasing of work and critical outages have to be scheduled and met during the low production season. Therefore, an experienced contractor with resources and expertise to handle the following project constraints is needed: i. The project needs to minimize the number of outages and strictly adhere to McMillan WTP outage criteria so that service interruptions are minimized. ii. Installation of a large submersible pump in an existing building with low headroom. iii. Concrete work, below grade with limited access in a confined space. iv. Replacement of travelling screens using multiple short duration outages. v. Deep trench construction related to an optional bid item to construct a new 24 inch drain line structure is in area of limited equipment access which must account for existing underground utilities nearby. Interested qualified Small Business (SB), Small Disadvantaged Business (SDB), Service Disabled Veteran Owned SB (SDVOSB), Veteran-Owned Small Business (VOSB), Historically Underutilized Business Zones (HUBZones), or Qualified Section 8(a) certified firms should submit a concise narrative and specific project examples of similar size and scope that demonstrate their experience in: 1. Installation of large submersible pumps including associated electrical gear. 2. Performing concrete structural reinforcing and repairs to include formwork installation and rebar placement. 3. Concrete work, below grade with limited access in a confined space. 4. Deep trench construction in areas of limited equipment access with underground utilities nearby. 5. Replacement of traveling screens. 6. Successful installation of large sluice gates, flap gates, valves, their mechanical actuators and large pipe modifications. Capability statements should include information and details of similar projects, to include demonstrated specialized experience and technical competence in: (a) Installation of large industrial equipment to include associated switch gear and controls. (b) Performing concrete structural reinforcing and repairs to include formwork installation and rebar placement. (c) Digital SCADA control system installation and modification. (d) Successful installation of large sluice gates, flap gates, valves, their mechanical actuators and large pipe modifications. (e) Excavation work in excess of 20 feet and tunneling. (f) Performing work in confined spaces with trained and certified personnel in a timely manner. In addition please provide a letter from the surety regarding the potential Small Business General Contractor's maximum bonding capability for a single contract action and total aggregate bonding capacity. Narratives shall be no longer than ten pages. Email responses are preferred. Comments will be shared with the Government and the project design team, but otherwise will be held in strict confidence. Responses must include the Offerors' name, POC phone number, SAM information and email address. Contracting Office Address: USACE District, Baltimore, 10 South Howard Street, Baltimore, MD 21203

More opportunities from Department Of Defense → W2SD Endist Baltimore

Same awarding agency

NAICS: 531120
New
Federal
U.S. Corps Marine Career Center- Huntington, WV
Solicitation # W912QR-27-Huntington-WV
The Baltimore District of the U.S. Army Corps of Engineers is soliciting lease proposals for approximately 1,271 usable square feet of commercial retail space for the U.S. Corps Marine Career Center. The desired location is within a one-mile radius of 901 4th Avenue, Huntington, West Virginia. Requirements for the space include a secondary egress and adequate parking for two government vehicles for both day and overnight use. Proposals must include the proposed rental amount, encompassing common area maintenance, taxes, and insurance, and are due by 5:00 pm on October 30, 2026. The selected lessor will be responsible for initial alterations, including the removal of abandoned cabling and fixtures, and must ensure the premises comply with the Architectural Barriers Act Accessibility Standard and applicable life safety codes such as NFPA 101 or the International Building Code. The lessor is required to maintain public liability and property damage insurance with a combined limit of at least 1,000,000 dollars, as well as fire and extended coverage insurance for the full replacement value of the building. Acceptance of the space is contingent upon a final inspection and the issuance of a valid Certificate of Occupancy. All prospective contractors must be registered in the System for Award Management with a Unique Entity Identifier and a notarized letter appointing an authorized Entity Administrator to ensure eligibility for award and electronic funds transfer payments.
Lessors of Nonresidential Buildings (except Miniwarehouses)

POSTED

6 days ago

DEADLINE

in 10 days
View Details

Find Active Opportunities Like This

Get AI-powered intelligence on the opportunities still open

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS