Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, October 14 at 2:00 PM EDT

Register Free →

Electrical Fit-out for Cooler/Freezer

Active
Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

AI Contract Overview

Show more

This subcontract opportunity is for the electrical fit-out of cooler and freezer units within Department of Veterans Affairs healthcare facilities located in North Chicago, Illinois. The scope of work involves installing electrical components and lighting, specifically vapor proof lights, standard switches, and wiring for plugs, frames, and heated vents. All installations must be fully wired, powered, and compliant with the National Electrical Code and specific healthcare facility electrical standards. The project is designated as a sole source set-aside for Service-Disabled Veteran-Owned Small Businesses under NAICS code 238210. Managed by the Network Contract Office 12, the solicitation was posted on October 7, 2026, with a response deadline of October 20, 2026.

General Info

NAICS

238210 - Electrical Contractors and Other Wiring Installation Contractors

Place of Performance

North Chicago, IL, 60064, USA

Set-Aside

SDVOSBC

Documents

This scope was carved out of 36C25227Q00480001.

The full solicitation package (2 documents), including the RFP, is on the prime solicitation, not on this scope.

View the prime solicitation

36C25227Q0048 - COOLERS AND FREEZER

AI Contract Breakdown

Uniform Contract Format

No documents to break down

The breakdown needs solicitation documents. None were found from this contract's source.

Timeline

Posted

subcontract

Response Deadline

Submission deadline

Response Deadline

Ready to pursue this opportunity?

Start your free trial to track this contract, build proposals with AI assistance, and manage your pipeline.

Organization & Contact Information

Show more
AgencyDepartment Of Veterans Affairs → 252-NETWORK Contract Office 12 (36C252)
ContactsNo contacts available
OfficeN/A
Office AddressN/A
ContactsNo contact information available

Full Description

Show more
Installs electrical components and lighting for walk-in units for prime contractors on VA healthcare facility projects. Installs vapor proof lights, standard switches, and wiring for heated vents, frames, and plugs. All work must meet National Electrical Code (NEC) and healthcare facility electrical standards. Delivers fully wired and powered lighting and heating systems.

Similar Contracts

Same NAICS industry code

NAICS: 238210
New
Federal
Fire Alarm and Mass Notification System Upgrades for DDJC, Tracy, CA
Solicitation # W9123826RA002
Solicitation W9123826RA002 is a firm-fixed-price construction procurement issued by the Department of Defense, W075 Endist Sacramento, for fire alarm and mass notification system upgrades at the Defense Distribution Depot San Joaquin in Tracy, California. The contractor is required to provide all labor, materials, equipment, and supervision to design, supply, and integrate existing Gamewell fire alarm controls, Federal Signal mass notification/voice evacuation, and King Fisher radio transceivers into a single panel for approximately 49 buildings and warehouses. Additionally, the scope includes replacing the central receiving system in Building 235 and installing a backup receiving system in Building 100. The project is divided into three primary contract line items covering design, cybersecurity, and construction, with a performance period running from April 15, 2027, to April 3, 2030. The government will award the contract based on the most advantageous balance between technical merit and cost, evaluating factors such as past experience, technical capabilities, design concepts, and small business participation. Key requirements include CMMC Level 1 certification, adherence to the Buy American Act, and compliance with ADA and ABA accessibility guidelines. The contractor must utilize specific quality control procedures, including the three-phase inspection process and the DrChecks review management system. Final payment is subject to a 0.05 percent withholding until the government accepts all as-built drawings and CADD files. Proposals must be submitted electronically via the PIEE website by October 13, 2026.
W075 Endist Sacramento

POSTED

about 12 hours ago

DEADLINE

in 6 days
View Details
NAICS: 238210
New
Federal
Micro Gin Motor Control Center Upgrade
Solicitation # 1232SA27Q0004
The USDA Agriculture Research Service is issuing a sources sought notice for the Micro Gin Motor Control Center Upgrade at the Cotton Ginning Research Unit in Stoneville, Mississippi. The project involves the demolition of existing hardwired devices, cable trays, and wiring, followed by the supply and installation of a new Motor Control Center, Programmable Logic Controllers, and a Human-Machine Interface control console. Key electrical requirements include the installation of a new 600-amp service panel in Building 26. All hardware must comply with NEMA, ANSI, and UL 845 standards, featuring UL labeling, NEMA type 1A enclosures with gasketed doors, and a 600V Cat 5 tested cabling system. Safety specifications require mechanically interlocked primary disconnects with padlocking accommodations for up to three locks. The overall project must be completed by April 1, 2027, with the PLC and HMI delivered within 120 days of contract acceptance. This acquisition falls under NAICS code 238210 with a size standard of 19.0 million dollars. Interested respondents must submit a capabilities synopsis of no more than five pages, including their UEL number, SAM validated business size, and relevant past performance with federal or commercial entities. Responses must be submitted in Word or PDF format to Frank Palmer by October 14, 2026. Future award evaluations are expected to follow the Tradeoff Process in accordance with FAR Part 12.
USDA Ars Afm Apd

POSTED

about 12 hours ago

DEADLINE

in 7 days
View Details
NAICS: 238210
New
Federal
Removal of Abandoned Telecommunications Equipment
Solicitation # 36C24527Q0025
The Department of Veterans Affairs is soliciting quotes for the removal of abandoned telecommunications equipment located within the Main Equipment Room (MER-3) of the Main Hospital Building at the VA Medical Center in Washington, DC. This total small business set-aside project, under NAICS code 238210, requires the contractor to provide all labor, materials, and supervision to disconnect, remove, and dispose of cabinets, racks, control panels, power supplies, cabling, conduit, and cable pressurization systems. The period of performance is scheduled from November 2, 2026, to March 2, 2027. Work must adhere to strict technical and safety standards, including NFPA 70, OSHA, and ANSI/TIA, while ensuring no interruption to critical life safety and security systems. Award will be based on a comparative evaluation to determine the most advantageous offer, rather than a low-price technically acceptable or trade-off process. Key evaluation requirements include a minimum of three years of relevant past performance, verified via CPARS or questionnaires, and a comprehensive technical description of the proposed methodology. The contract includes specific quality assurance hold points and a final punch list walkthrough with the VA Contracting Officer's Representative. Administrative requirements include electronic invoicing monthly in arrears and compliance with Davis-Bacon Act labor standards and personnel vetting procedures.
245-NETWORK Contract Office 5 (36C245)

POSTED

about 12 hours ago

DEADLINE

in 8 days
View Details

More opportunities from Department Of Veterans Affairs → 252-NETWORK Contract Office 12 (36C252)

Same awarding agency

NAICS: 238220
New
Federal
Z1DA--Replace Cast Iron Fittings 676-23-009
Solicitation # 36C25226B0037
Solicitation 36C25226B0037 is a 100 percent set-aside for Service-Disabled Veteran-Owned Small Businesses (SDVOSB) to perform the Replace Cast Iron Fittings project at the Tomah VA Medical Center in Wisconsin. The project involves providing all labor, materials, equipment, and supervision to remove and replace cast iron or malleable/ductile iron fittings and pipe components, including valves and steam traps, within steam generation and distribution systems operating at 15 psig or greater or condensate systems exceeding 257 degrees Fahrenheit. The estimated project magnitude is between 5 million and 10 million dollars, with a performance period of 420 calendar days after the notice to proceed. Award will be granted to the responsible bidder with the lowest responsive base bid. Bidders must provide their current Experience Modification Rate (EMR) and safety records, including OSHA 300 forms for 2023 through 2025, to determine responsibility. As a special trade construction contract, the awarded contractor must certify that they will not pay more than 75 percent of the government paid amount to firms that are not certified SDVOSBs or VOSBs, excluding the cost of materials. Compliance is subject to VA review of records, and failure to act in good faith may result in fines, suspension, debarment, or prosecution. The contract requires a bid bond upon submission, with performance and payment bonds required from the successful bidder. Work must adhere to the Davis-Bacon Act for prevailing wages and the Buy American statute for construction materials. Quality control is mandatory, involving a series of inspections including punch-out, pre-final, and final acceptance inspections conducted by the contractor and the government. All work must comply with federal, state, and local regulations, as well as VA security management programs and specific technical standards such as NFPA 90A and UL 181.
Plumbing, Heating, and Air-Conditioning Contractors

POSTED

about 12 hours ago

DEADLINE

in 9 days
View Details
NAICS: 561710
New
Federal
S207--On-call Pest Mitigation Services – Primarily for Bed Bugs for the Adam Benjamin Jr., VA Outpatient Clinic Crown Point, Indiana
Solicitation # 36C25227Q0038
Solicitation 36C25227Q0038 is a request for quotes for on-call pest mitigation services, primarily targeting bed bugs and ticks, at the Adam Benjamin Jr. VA Outpatient Clinic in Crown Point, Indiana. This firm-fixed-price contract is set aside for Service-Disabled Veteran-Owned Small Businesses (SDVOSB) and covers a leased facility of approximately 44,000 square feet. The performance period consists of a base year ending October 31, 2027, with four subsequent option years, for a total potential duration of five years. The contractor must provide 24/7/365 availability, with initial assessments required on-site within four hours of notification and definitive mitigation completed within 24 to 48 hours depending on the day of the week. Services must be performed outside of patient care hours, which are Monday through Friday from 7:00 a.m. to 5:00 p.m. The contractor is required to use non-toxic or low-toxicity treatments in patient care areas and must adhere to all healthcare environment safety standards. Key deliverables include PDF reports of all findings and actions transmitted via email to the Contracting Officer's Representative. Award will be based on a comparative evaluation of price, technical capability—including the provision of an Indiana pest control business license and technician certifications—and relevant experience. Invoicing must be submitted electronically via the Tungsten Network by the tenth of the following month.
Exterminating and Pest Control Services

POSTED

about 12 hours ago

DEADLINE

in 6 days
View Details
NAICS: 336999
New
Federal
2320--Utility Vehicle
Solicitation # 36C25227Q0047
Solicitation 36C25227Q0047 is a request for the acquisition of three Utility Task Vehicles (UTVs) for the Tomah VA Medical Center in Wisconsin. This procurement is a total set-aside for Service-Disabled Veteran-Owned Small Businesses (SDVOSB) under NAICS code 336999. The Department of Veterans Affairs is seeking brand name or equal products, specifically referencing the Polaris Ranger XP 1000 Northstar Premium NX. Award will be determined using the Lowest Price Technically Acceptable (LPTA) method, provided the vehicles meet all minimum salient characteristics. Technical requirements for the vehicles include a liquid-cooled 4-stroke twin-cylinder gasoline engine with at least 999 cc and 82 horsepower, an automatic transmission with selectable AWD and 2WD, and a minimum two-person side-by-side seating configuration. The vehicles must feature a rear cargo box capacity of 1,000 lbs, a towing capacity of 2,500 lbs, a payload above 700 lbs, and a minimum ground clearance of 13 inches. Essential safety and comfort features include factory-installed air conditioning, a heater, electronic power steering, full doors, a windshield, a roll-over protection structure (ROPS), and three-point seat belts. A one-year warranty is required. The contract is FOB Destination, with delivery and acceptance occurring at the Tomah VA Medical Center. Invoicing must be submitted electronically to the VA Financial Services Center in Austin, Texas. Compliance with various Federal Acquisition Regulation (FAR) clauses is mandatory, including prohibitions on convict labor, requirements for contractor employee whistleblower rights, and a specific deviation prohibiting racially discriminatory diversity, equity, and inclusion (DEI) activities.
All Other Transportation Equipment Manufacturing

POSTED

about 12 hours ago

DEADLINE

in 6 days
View Details
NAICS: 333415
New
Federal
36C25227Q0048 - COOLERS AND FREEZER
Solicitation # 36C25227Q00480001
Solicitation 36C25227Q0048 is a sole source procurement set aside for Service-Disabled Veteran-Owned Small Businesses (SDVOSB) under NAICS code 333415. Issued by the Department of Veterans Affairs Network Contract Office 12, the requirement is for the provision of an indoor walk-in cooler and freezer system to be installed on-grade at the Captain James A. Lovell Federal Health Care Center in North Chicago, Illinois. The solicitation was posted on October 7, 2026, with a response deadline of October 20, 2026. The technical specifications call for a combined unit measuring 44 feet 6 3/4 inches by 31 feet 7 inches by 8 feet 6 inches. The freezer requires 5 1/2 inch walls and ceilings with a 5 1/4 inch floor, while the cooler requires 4 inch walls and ceilings. The unit must feature 26 gauge stucco white interior and exterior walls and a galvanized exterior ceiling and floor. Key accessories include vapor proof lights, Kason hinges, heated vents, dial flush thermometers, a 36 inch depth exterior ramp, and heated frames and plugs. Compliance is required with Section 312 of the Energy Independence and Security Act of 2007, UL1715 testing, and 2021 IEC C403.11 standards for wood frame construction. The unit is engineered to support only its own weight, and any modifications or storage on top may void manufacturer warranties. Special installation precautions are noted regarding concrete curing ventilation and the use of muriatic acid. The primary point of contact for this effort is Contracting Officer Jennifer Mead.
Air-Conditioning and Warm Air Heating Equipment and Commercial and Industrial Refrigeration Equipment Manufacturing

POSTED

about 12 hours ago

DEADLINE

in 13 days
View Details

Ready to Pursue This Opportunity?

Get AI-powered intelligence on this solicitation and the ones like it

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS