Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, October 28 at 2:00 PM ET

Register Free →

This Sources Sought opportunity from Department Of Homeland Security was posted on January 7, 2014. The submission period has ended. Browse the details below for market research, or find similar active opportunities.

ENGINEERING SERVICES: CONSULTANT TO EVALUATE AND MAKE RECOMMENDATIONS TO USCG TO MAINTAIN, MODIFY, RE-DESIGN, OR MAKE NEW SYSTEM FOR AN EXISTING SUBSEA/UNDERWATER CRUDE OIL COLLECTION CONTAINMENT SYSTEM

Closed
FPN-N13024Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

Active Opportunities Like This One

NAICS: 541330
New
SLED
Fire Alarm engineering for Lewis County
Solicitation # 2026-RFQ-040
Lewis County is soliciting qualifications under solicitation 2026-RFQ-040 for a professional engineering firm to provide comprehensive design and engineering services for fire alarm systems. The project encompasses several County-owned facilities, including the IT Building, Historic Courthouse, Health Building, and Lewis County Jail. The selected firm will be responsible for conducting on-site evaluations to determine the remaining useful life of existing systems, assessing code compliance with NFPA 72, IBC, and IFC standards, and developing bid-ready construction drawings and technical specifications. All designs must be stamped by a licensed electrical engineer familiar with Washington State fire alarm requirements and must integrate smoothly with existing infrastructure to ensure standardized maintenance and operations. Proposals are due by November 10, 2026, via the OpenGov platform and will be evaluated by a committee of at least three County employees using a points-based system. The evaluation criteria are equally weighted at 20 percent each across four categories: firm qualifications (including NICET certifications and licensed engineer availability), responsiveness and capacity to begin work within 30 days, regulatory compliance and permitting records, and the clarity and detail of blueprint designs. Applicants must provide a statement of qualifications, three public agency references from the last five years, and resumes of key personnel. The contract is administered by Matt Patana, Capital Infrastructure Specialist, based in Chehalis, Washington.
Capital Infrastructure

POSTED

about 15 hours ago

DEADLINE

in 21 days
NAICS: 541330
New
International
Provision of Consulting Services for Regional Basement Flooding Mitigation Program Strategic Plan
Solicitation # P-1353-26
The Region of Halton is soliciting proposals for a consulting firm to conduct a comprehensive review of its existing Basement Flooding Mitigation Program and develop a three-year Strategic Plan. The primary objectives are to reduce basement flooding risks, enhance wastewater system resilience, and decrease wet-weather flows. The project is expected to be completed within nine months of kick-off and includes key deliverables such as a current-state assessment report, a prioritization framework for initiatives, a final strategic plan with an implementation roadmap, and a performance measurement and reporting framework. The selected consultant must provide a Project Manager with PMP certification or equivalent credentials. The contract will be awarded based on a scoring system where the technical proposal accounts for 80 points and the cost proposal accounts for 20 points. Proponents must achieve a minimum technical score of 70% to be considered for award and may be invited to a 30-minute presentation. Mandatory submission requirements include a technical proposal, a signed Vendor Code of Conduct Acknowledgement Form, and a cost proposal submitted via the online bidding system by November 12, 2026. The agreement is governed by a modified Standard Agreement and Supplementary Conditions, requiring the consultant to maintain specific insurance coverages: 5 million dollars for Commercial General Liability, 2 million dollars for Automobile Liability, and 2 million dollars for Professional Liability. Additionally, the consultant must provide a WSIB clearance certificate upon award and with every monthly electronic invoice. All produced materials remain the sole property of the Region of Halton, and deliverables must comply with the Ontario Building Code and the Accessibility for Ontarians with Disabilities Act.
Region of Halton

POSTED

about 17 hours ago

DEADLINE

in 23 days
NAICS: 541330
New
SLED
REQUEST FOR PROPOSAL (RFP) STAR Centre Energy Modernization Project Energy Audit
Solicitation # BPM059233
The City of Havre de Grace is seeking proposals for a comprehensive energy audit of the STAR Centre, the city's largest public building, as the first phase of an Energy Modernization effort. This grant-funded project, supported by the Maryland Energy Administration Local Government Energy Modernization Program Grant 52-600796, requires a contractor to perform an ASHRAE Level 1 walkthrough Energy Audit. The scope includes documenting baseline operating conditions, analyzing utility billing data, evaluating eligibility for utility rebates, and providing a detailed report of energy efficiency measures for lighting, HVAC, and building envelope weatherization. Additionally, the contractor must develop a Monitoring Based Commissioning Plan (MBCx) to support future energy management and continuous performance monitoring. The contract will be awarded based on the best value to the city, considering the technical approach, cost factor, and the bidder's experience. Eligible offerors must be established businesses with at least five years of industry experience and must be in good standing with the State of Maryland, Harford County, and the City of Havre de Grace. Required submission documents include a Maryland Business License, a Certificate of Good Standing, an IRS W-9, and evidence of insurance covering General Liability, Workers' Compensation, and Errors and Omissions. Proposals must be submitted electronically via Beacon Bid by November 23, 2026. The selected vendor must be able to complete the audit and deliverables within a 60-day period, with a final project completion deadline of February 5, 2027. Payment will be made upon the successful completion of services, with the possibility of progress payments based on a satisfactory schedule.
City of Havre de Grace

POSTED

about 17 hours ago

DEADLINE

in about 1 month

AI Contract Overview

Show more

The Department of Homeland Security, through the U.S. Coast Guard, is seeking an engineering consultant to evaluate and provide recommendations for a subsea crude oil collection containment system at Mississippi Canyon Lease Block 20. Following a platform collapse caused by Hurricane Ivan, an existing containment system consisting of steel domes, hoses, and a separator has failed to eliminate a daily crude oil sheen on the water surface. Under administrative order 12-001, the consultant will assist the government in determining whether to maintain, modify, redesign, or uninstall the current system and will perform an independent assessment of a new proposed design to ensure it is suitable for the specific environmental conditions of the site. The selected contractor must possess highly specialized technical expertise not currently available within the U.S. Coast Guard, specifically regarding hydrocarbon emissions through fine-grained sediments and marine structure engineering. Key requirements include proficiency in seabed flux measurements, analyzing temporal and spatial variability in emissions, and understanding the geologic controls affecting those emissions. Additionally, the consultant must be expert in the design and failure modes of seabed containment systems, oil volumetric estimation on the sea surface, and modeling the fate of oil and gas droplets within the water column.

General Info

NAICS

541330 - Engineering Services

Place of Performance

Mississippi Canyon Lease Block 20, south of New Orleans, LA (approximately 12 miles from shore), centered at 28 degrees 56' 12., NEW ORLEANS, LA, USA

Set-Aside

NONE

Documents

0

No documents available

Documents will appear here when they are available.

AI Contract Breakdown

Uniform Contract Format

No documents to break down

The breakdown needs solicitation documents. None were found from this contract's source.

Timeline

PhaseClosed
Posted

Sources Sought

Response Deadline

Deadline has passed

Submission Closed

Find active opportunities like this

Start your free trial to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyDepartment Of Homeland Security → LOG-9
Contacts1 person available
OfficeNORFOLK, VA, 23510, USA
Office AddressNORFOLK, VA, 23510, USA
Contacts
Jerry HendricksContracting Officer

Full Description

Show more
A mudslide triggered by Hurricane Ivan's storm surge toppled a platform at Mississippi Canyon (MC) Lease Block 20. The platform's wells were covered by more than 100 feet of mud and sediment and as a result of structural damage, plumes containing crude oil and gas discharged into the Gulf of Mexico, creating a sheen on the surface of the water. To mitigate the discharge, in 2009, a subsurface containment system was installed at the MC 20 site, however, there continues to be a visible crude oil sheen on the surface of the water daily. The subsea containment system consists of: three 2700 cubic foot (100barrel capacity) steel domes, hoses, a marker buoy and a 50 barrel oil/water separator. U.S. Coast Guard administrative order 12-001 directed the Platform Owner to begin the design a new pollution dome system that is suitable for the environmental conditions found at the MC20 discharge site. The dome system is located at Mississippi Canyon Lease Block 20, south of New Orleans, LA (approximately 12 miles from shore), centered at 28 degrees 56' 12.619" and 088 degrees 58' 10.303" W. The water depth is approximately 440 feet. An engineering consultant is required to assist the USCG by evaluating and making recommendations to modify, re-design and/or un-install the current subsea containment system at MC 20 and also review new proposed containment system to eliminate the ongoing sheen and recover product. The USCG requires an engineering consultant to assist with an independent government assessment on the effectiveness of a new dome system. This assessment requires unique skills and capabilities related to hydrocarbon emissions through fine grained sediments, as well as marine structure engineering and the underlying physical processes associated with natural hydrocarbon seepage; skills not currently available within the U.S. Coast Guard. The contractor shall meet the following requirements: 1.Expertise in seabed flux measurements of oil and gas from natural and anthropogenic sources. 2. Expertise in analyzing temporal and spatial variability in seabed emissions. 3. Expertise in design, implementation, and failure modes of containment systems for collecting oil and gas at the seabed 4. Expertise in geologic controls on variability in emissions. 5. Expertise in oil volumetric estimation on the sea surface and in oil slick processes affecting oil slicks on the sea surface. 6. Expertise in modeling the fate of oil and gas droplets in the water column - a key factor to containment system design.

More opportunities from Department Of Homeland Security → LOG-9

Same awarding agency

Find Active Opportunities Like This

Get AI-powered intelligence on the opportunities still open

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS