Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, November 11 at 2:00 PM ET

Register Free →

This Sources Sought opportunity from Department Of Veterans Affairs was posted on March 17, 2023. The submission period has ended. Browse the details below for market research, or find similar active opportunities.

F101--Radon Level Testing

Closed
36C24123Q0484Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

Active Opportunities Like This One

General Info

NAICS

541380 - Testing Laboratories and Services

Place of Performance

Togus VAMC 1 VA Center, Augusta, ME, 04330, USA

Set-Aside

NONE

Documents

1

36C24123Q0484 - Radon Level Testing

DOCX, Low prioritysources-sought
Low

AI Contract Breakdown

Uniform Contract Format

Contract not broken down yet

CLEATUS splits the solicitation into Uniform Contract Format (UCF) sections: scope, pricing, deliverables, and evaluation criteria.

Timeline

PhaseClosed
Posted

Sources Sought

Response Deadline

Deadline has passed

Submission Closed

Find active opportunities like this

Get full access to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyDepartment Of Veterans Affairs → 241-NETWORK Contract Office 01 (36C241)
Contacts1 person available
OfficeTOGUS, ME, 04330, USA
Office AddressTOGUS, ME, 04330, USA
Contacts
Kenya MitchellContract Specialist

Full Description

Show more
This is a Sources Sought notice only. This is not a request for quotes and no contract will be awarded from this announcement. The Government will not provide any reimbursement for responses submitted in response to this Source Sought notice. Respondents will not be notified of the results of the evaluation. If a solicitation is issued it shall be announced at a later date, and all interest parties must response to that solicitation announcement separately. Responses to this notice are not a request to be added to a prospective bidders list or to receive a copy of the solicitation The purpose of this announcement is to perform market research to gain knowledge of potential qualified sources and their size classification relative to NAICS 541380, Testing Laboratories a size standard $16.5 Million The Department of Veterans Affairs (VA), Network Contracting Office 1 (NCO 1) is seeking to identify any vendor capable of providing Radon Level Testing at the Togus VAMC per the Performance Work Statement below. This Sources Sought notice provides an opportunity for respondents to submit their capability and availability to provide the requirement described below. Vendors are encouraged to submit information relative to their capabilities to fulfill this requirement, in the form of a statement that addresses the specific requirement identified in this Sources Sought. Information received from this Sources Sought shall be utilized to facilitate the Contracting Officer s review of the market base, for acquisition planning, size determination, and procurement strategy. Submission Instructions: Interested parties who consider themselves qualified to perform the services are invited to submit a response to this Sources Sought Notice by 5 PM EST, 24 March, 2023. All responses under this Sources Sought Notice must be emailed to Kenya Mitchell with RFI # 36C24123Q0484 in the subject line. Telephone inquiries will not be accepted or acknowledged, and no feedback or evaluations will be provided to companies regarding their submissions. Interested parties should complete the attached Sources Sought Worksheet. Parties may submit additional information related to their capabilities, provided it contains all the requirements contained in the Sources Sought Worksheet. Responses to this Sources Sought shall not exceed 8 pages. In addition, all submissions should be provided electronically in a Microsoft Word or Adobe PDF format. Attachment 1 Sources Sought Worksheet QUALIFICATION INFORMATION: Company / Institute Name: _______________________________________________________ Address: ______________________________________________________________________ Phone Number: ________________________________________________________________ Point of Contact: _______________________________________________________________ E-mail Address: ________________________________________________________________ Unique Entity Identifier (UEI) #: ___________________________________________________ CAGE Code: __________________________________________________________________ SAM Registered: (Y / N) Other available contract vehicles applicable to this sources sought (GSA/FSS/NASA SEWP/ETC): __________________________________________________________________ ______________________________________________________________________________ ______________________________________________________________________________ SOCIO-ECONOMIC STATUS: VIP Verified SDVOSB: (Y / N) VIP Verified VOSB: (Y / N) 8(a): (Y / N) HUBZone: (Y / N) Economically Disadvantaged Women-Owned Small Business: (Y / N) Women-Owned Small Business: (Y / N) Small Business: (Y / N) NOTE: Respondent claiming SDVOSB and VOSB status shall be registered and Center for Veterans Enterprise (CVE) verified in VetBiz Registry www.vetbiz.gov. BASED ON THE RESPONSES TO THIS SOURCES SOUGHT NOTICE/MARKET RESEARCH, THIS REQUIREMENT MAY BE SET-ASIDE FOR SDVOSB, VOSB, SMALL BUSINESSES OR PROCURED THROUGH FULL AND OPEN COMPETITION. CAPABILITY STATEMENT: Provide a brief capability and interest in providing the service as listed in Attachment 2 PERFORMANCE WORK STATEMENT with enough information to determine if your company can meet the requirement. The capabilities statement for this Sources Sought is not a Request for Quotation, Request for Proposal, or Invitation for Bid, nor does it restrict the Government to an ultimate acquisition approach, but rather the Government is requesting a short statement regarding the company s ability to provide the services outlined in the PWS. Any commercial brochures or currently existing marketing material may also be submitted with the capabilities statement. This synopsis is for information and planning purposes only and is not to be construed as a commitment by the Government. The Government will not pay for information solicited. Respondents will not be notified of the results of the evaluation. ______________________________________________________________________________ ______________________________________________________________________________ ______________________________________________________________________________ ______________________________________________________________________________ ______________________________________________________________________________ ______________________________________________________________________________ ______________________________________________________________________________ ______________________________________________________________________________ ______________________________________________________________________________ ______________________________________________________________________________ ______________________________________________________________________________ ______________________________________________________________________________ ______________________________________________________________________________ Attachment 2 PERFORMANCE WORK STATEMENT Radon Level Testing Place of Performance: TOGUS VA MEDICAL CENTER 1 VA Center AUGUSTA, ME Period of Performance: 30 days from NTP Contractor will Install, process, and report on Radon decay levels using a variety of testing mediums to include continuous radon monitors (CRM) and liquid scintillating testers. Test for radon in areas of highest concerns of VA Maine as compliant with National Radon testing procedures. Purpose of testing is to determine initial levels of Radon decay as a precursor to continual radon monitoring or possible course of action to install active mitigation systems. The Environmental Protection Agency (EPA) has determined lowering the radon levels to acceptable federal levels (4.0 pCI/L), with the recommendation that anything over (2.7 pCi/L) be considered for remediation. Along with these testing procedures include the quality assurance practice of periodic duplication, spike testing, and blind testing at acceptable limits to ensure accuracy. The testing shall be implemented in an extensive complex to include large building structures, residential homes, subterranean corridors, and clinical/medical areas. Include thirty-eight (38) structures as deemed by VA Maine, and encompass the use of upwards of one hundred-eighty (180) tests with a minimum of one hundred sixty-six (166) to be determined at actual placement. Primarily test those areas that are mostly sub-floor (basement/crawlspace), or areas prone for possible exacerbation on first inhabitable levels of structures that may possess levels of radon exposure. Place testers and quantities as appropriate for accurate industry standards and sufficient to obtain true readings of the space. Perform testing in a manner that will minimize the variation of controls caused by human intervention whereas is possible. Test with active ventilation already in place operating as normally to ensure established common practices are in place presently. Contractor will Furnish all materials, labor, and reports detailing the findings with the above specifications. Conduct a single measurement session based on guidelines for assessment of large building structures. VA Maine will consider an elongated (multiple) measurement session to lower the cost due for the ability to use more mechanical monitoring, and less lab processing. The test shall include placement and cataloging of tests, processing of test via computerized testing modules or independent authorized testing facilities, conducting procedures to ensure proper readings and quality assurance measures, a formalized report detailing the findings of tests, and a plan of action showing areas of concern or needing mitigation action (the A&A requirements do not apply - a Security Accreditation Package is not required). Provide subsequent follow-up of proposed mitigation needs as necessary for areas highlighted from reports.

More opportunities from Department Of Veterans Affairs → 241-NETWORK Contract Office 01 (36C241)

Same awarding agency

NAICS: 532490
New
Federal
W038--Rental & Support Services for Wheeled Loaders w/3yard bucket
Solicitation # 36C24126Q0815
The Department of Veterans Affairs VA Maine Healthcare System Togus is soliciting quotes for the rental and support of two wheeled loaders equipped with 3-yard buckets and Fusion couplers. The equipment will be used for snow removal from parking lots at the Togus VAMC campus, with an anticipated start date of November 9, 2026. The rental is on a month-to-month basis for an undetermined duration, estimated between one and six months. Each loader must meet or exceed specifications comparable to CAT 926 or CAT 930 models, featuring 160 to 170 hp Tier 4 Final engines, ROPS/FOPS certified cabs with climate control, and four liquid-filled tires for added weight. The selected contractor must provide comprehensive 24/7 service and support, including all preventive maintenance and repairs. Repairs must be initiated within 24 hours of notification, or a replacement loader must be provided at no additional cost. This procurement is a total set-aside for Service-Disabled Veteran-Owned Small Businesses (SDVOSB) under NAICS code 532490. Award will be made to the technically acceptable vendor offering the lowest evaluated price, based on an evaluation of technical capability, past performance, and total price. Quotes must include a monthly rental rate and itemized delivery and pickup charges, with a submission deadline of November 2, 2026.
Other Commercial and Industrial Machinery and Equipment Rental and Leasing

POSTED

about 14 hours ago

DEADLINE

in 5 days
View Details
NAICS: 238990
New
Federal
Amendment 0001- Replacement-in-Kind Repair of Existing Perimeter Security Fence (Ameristar Impasse Trident) Brand Name or Equal
Solicitation # 36C24127Q0041
The Department of Veterans Affairs VA Boston Healthcare System is soliciting quotes for a firm-fixed-price contract to perform a localized replacement-in-kind repair of the perimeter security fence at the Brockton VA Campus in Brockton, Massachusetts. The project focuses on restoring five affected fence bays and six associated post locations that were damaged by winter snow-removal activities. The benchmark product is the Ameristar Impasse Trident system, and any proposed equal must meet all salient characteristics, including the use of corrosion-resistant, tamper-resistant hardware and a uniform transition in profile, color, and finish to the existing fence. The scope is strictly limited to the damaged sections and does not authorize any redesign or expansion of the perimeter. This procurement is a total set-aside for Service-Disabled Veteran-Owned Small Businesses (SDVOSB). The period of performance is scheduled from December 1, 2026, to January 31, 2027. Award will be made to the responsible offeror determined to be most advantageous based on price, past performance, and technical capabilities. Proposals must be submitted in three separate PDF volumes covering technical approach, past performance, and pricing. Following Amendment 0001, a site visit is scheduled for November 10, 2026, and the closing date for the receipt of offers has been extended to November 13, 2026, at 1:00 PM EST.
All Other Specialty Trade Contractors

POSTED

about 14 hours ago

DEADLINE

in 15 days
View Details

Earlier notices in this NAICS code

Posted before this notice, open and closed

Find Active Opportunities Like This

Get AI-powered intelligence on the opportunities still open

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS