The City of San Diego is procuring the construction of a new 4-story fire station at the corner of 47th Street and Fairmount Avenue, on a 1.28-acre site in the 92102 zip code. The facility will span 22,443 square feet and stand 64 feet tall, featuring two apparatus bays totaling 5,200 square feet, ten bunk rooms totaling 5,850 square feet, a 1,435-square-foot exercise room, a kitchen, a trash enclosure, an emergency generator, and a fuel tank. The project includes 12-foot retaining walls, extensive grading, stormwater management systems, and a dedicated parking lot. Construction will utilize an off-site staging area at Sunshine Berardini Park along Federal Boulevard. The work must adhere to the City’s Whitebook and Greenbook Standard Specifications for Public Works Construction, the California Building Code (Title 24, 2019 Edition), ACI 318-14 for structural concrete, and the SDRWQCB MS4 Permit for stormwater pollution prevention. A Geotechnical Investigation Report, certified grading and foundation plans, and a Stormwater Pollution Prevention Plan are required deliverables. The project timeline includes 20 days for site preparation, 280 days for grading, and 380 days for building construction, with an estimated total duration of three years. Special contract requirements mandate compliance with CARB Tier 4 Final or better engine standards for all diesel equipment rated at 50 horsepower or greater, with provisions for alternative equipment if emissions remain below CEQA cancer risk thresholds. A Qualified Biologist must be retained throughout construction to implement a Biological Construction Mitigation/Monitoring Exhibit aligned with the City Biology Guidelines, Multiple Species Conservation Program, CEQA, and the Endangered Species Act, including preconstruction meetings and ongoing on-site monitoring. Stormwater management requires a Storm Water Pollution Prevention Plan for land disturbances exceeding one acre and a Storm Water Quality Management Plan for Priority Development Projects generating 10,000 square feet or more of impervious surface. The City’s Land Development Manual and Municipal Code govern construction practices. Acceptance of work is contingent upon formal verification from the curation institution as part of the Final Monitoring Report, with approval issued by the City’s Responsible Entity. Proposals must be submitted electronically to CIP-CEQA@sandiego.gov or in hard copy to Nancy Graham at 5

General Info

San Diego to build 4-story fire station with stormwater systems, biologic monitoring, and emissions-compliant equipment per city and state codes.

Agency

California → City of San Diego

NAICS

236220 - Commercial and Institutional Building ConstructionView NAICS

Place of Performance

Fairmount Ave. and 47th St., San Diego, CA, 92102

Set-Aside

NONE

Documents

(19)

Appendix C Air Quality and Greenhouse Gas Technical Report for Fairmount Avenue Fire Station Project

PDFtechnical-report

Notice of Preparation for Environmental Impact Report - Fairmount Avenue Fire Station Project

PDFpresolicitation

Appendix F.3 Storm Water Quality Management Plan for Fairmount Fire Station

PDFstorm-water-quality-management-plan

Fairmount Avenue Fire Station Environmental Summary

PDFenvironmental-summary

Appendix I Cultural Resources Phase I Inventory Letter Report for Fairmount Avenue Fire Station Project

PDFcultural-inventory-report

Appendix D Biological Resources Technical Report for Fairmount Avenue Fire Station Project

PDFtechnical-report

Preliminary Drainage Study for Fairmount Avenue Fire Station

PDFstudy-report

Appendix F Floodplain Evaluation Report for Fairmount Avenue Fire Station

PDFfloodplain-evaluation-report

Appendix J.2 Water Budget and Landscape Worksheet for Fairmount Ave. Fire Station

PDFsow

Appendix J Sewer and Water Study for Fairmount Avenue Fire Station

PDFstudy-report

Appendix K Fire Fuel Load Modeling Report for Fairmount Fire Station

PDFsow

Fairmount Avenue Fire Station Project Draft Environmental Impact Report August 2025

PDFdeir

Updated Geotechnical Investigation Fairmount Avenue Fire Station

PDFgeotechnical-report

Draft Environmental Impact Report Notice of Availability for Fairmount Avenue Fire Station Project

PDFspecial-notice

Appendix B Transportation Technical Memorandum for Fairmount Avenue Fire Station

PDFtechnical-memorandum

Appendix E.3 Geotechnical Letter for Fairmount Avenue Fire Station

PDFgeotechnical-letter

SCH 2024010280 Fairmount Avenue Fire Station Notice of Completion

PDFnotice-of-completion

Geotechnical Report for Fairmount Avenue Fire Station

PDFgeotechnical-report

Appendix G Noise Technical Report Update - Fairmount Avenue Fire Station Project

PDFsow

AI Contract Breakdown

Uniform Contract Format

Sign up to view the full breakdown with detailed analysis of each section.

Timeline

Posted

forecast

Ready to pursue this opportunity?

Start your free trial to track this contract, build proposals with AI assistance, and manage your pipeline.

Organization & Contact Information

Show more
AgencyCalifornia → City of San Diego
Contacts2 people available
OfficeN/A
Organization / Agency
California → City of San Diego
Office AddressN/A
Contacts
Nancy GrahamProgram Manager
Carey FernandesSenior CEQA Project Manager

Interested Companies (1)

Show more
Dudek
Encinitas, CA

Full Description

Show more
The project includes the development of a 4-story fire station and parking lot at 47th Street and Fairmount Avenue, which will serve to add additional emergency and medical response services to the surrounding community. The proposed fire station would occur on a 1.28-acre site and includes 12 foot retaining walls, one garage with two apparatus bays (5,200 square feet), exercise room (1,435 square feet), kitchen,10 bunk rooms (totaling 5,850 square feet). The station will also be serviced by a trash enclosure, an emergency generator, and a fuel tank. In total, the proposed fire station would be 22,443 square feet and 64 feet tall. During construction, an off-site staging area at Sunshine Berardini Park along Federal Boulevard would be utilized.

Similar Contracts

Same NAICS industry code

NAICS: 236220
New
Enlisted Unaccompanied Personnel Housing at Eglin AFB, FL
Solicitation # enlisted-unaccompanied-personnel-housing-eglin-afb-fl
The contract solicits the construction of two two-story enlisted unaccompanied personnel housing barracks at Eglin Air Force Base in Florida, each designed to accommodate 120 personnel across 32 individual units. Each unit is equipped with a kitchen, dining area, living area, and laundry room, while the buildings include shared amenities such as lobbies, elevators, entrance vestibules, exercise rooms, day rooms, lounges, and dedicated mechanical, electrical, and communications spaces. The project extends beyond the structures to encompass comprehensive site development, including parking facilities for vehicles and motorcycles, a large open pavilion, basketball and volleyball courts, concrete sidewalks, roadways, grading, storm sewer systems, utilities, landscaping, and related incidental work. All construction activities must comply with a broad range of trade scopes including demolition, sitework, concrete, masonry, steel, millwork, insulation, roofing, waterproofing, doors and hardware, glass and glazing, drywall, flooring, paint, elevators, plumbing, HVAC, fire protection, electrical systems, fencing, asphalt paving, and landscaping. The solicitation is issued by Roy Anderson Corp as the general contractor and is targeted exclusively toward small businesses, with set-asides available for Small Business, Small Disadvantaged Business, Women-Owned Small Business, HUBZone Small Business, Veteran-Owned Small Business, and Service-Disabled Veteran-Owned Small Business entities. Subcontractors from Minority Business Enterprises, Disadvantaged Business Enterprises, Women’s Business Enterprises, and other certified categories are encouraged to participate. The contract incorporates mandatory equal employment opportunity requirements under Executive Order 11246, Section 503 of the Rehabilitation Act of 1973, and the Vietnam Era Veterans’ Readjustment Assistance Act of 1974, ensuring compliance with affirmative action and non-discrimination standards as defined in 41 CFR 60-4. Proposals must be submitted by Tuesday, August 18, 2026, at 1:00 PM Central Time, with interested bidders required to notify the point of contact, Patrice Lindman, via email or fax to confirm intent to bid. No contract value, pricing structure, period of performance, or bonding requirements are specified in the solicitation materials, and the award will be based on submissions from qualified small business entities meeting the stated technical and compliance criteria.
Roy Anderson Corp

POSTED

about 6 hours ago

DEADLINE

in 10 days
View Details
NAICS: 236220
New
RFO AWP-1072, IIJA: ZUA CCF Environmental Wing and Underground Utilities, Hagatna, GU
Solicitation # rfo-awp-1072-iija-zua-ccf-environmental-wing-underground-utilities-hagatna-gu
The contract pertains to the construction of a new Environmental Wing and associated underground utility improvements at a facility in Hagatna, Guam, with a construction value exceeding $10 million. The project includes the demolition of existing structures, comprehensive upgrades to the building’s electrical and HVAC systems, and significant underground utility enhancements. The work is classified under multiple NAICS codes including 236220, 236210, 237990, and 238110, reflecting the broad scope of construction activities involved. This solicitation is set aside for small business concerns including Small Disadvantaged Businesses, Women-Owned Small Businesses, HUBZone, Veteran-Owned, and Service-Disabled Veteran-Owned Small Businesses, as well as Alaskan Native Corporations. Interested firms must respond to the solicitation by the deadline of August 27, 2026, and should contact Anna Ma, Subcontract Administrator at Parsons, via email at anna.t-ctr.ma@faa.gov to express confirmed interest. The solicitation, identified as RFO AWP-1072, IIJA: ZUA CCF Environmental Wing and Underground Utilities, was posted on August 7, 2026, under the PTSI Managed Services, Inc. agency. The project’s location is exclusively in Guam, and all responses must align with the Small Business Administration’s set-aside requirements. No physical office address is listed, and inquiries should be directed through the provided point of contact.
PTSI Managed Services, Inc.

POSTED

about 6 hours ago

DEADLINE

in 19 days
View Details
NAICS: 236220
New
Windsor SECONDARY TREATMENT SYSTEM UPGRADES PROJECT
Solicitation # windsor-secondary-treatment-system-upgrades-project-0
The Windsor Secondary Treatment System Upgrades Project involves a major expansion and modernization of the Water Reclamation Facility’s aeration basin, requiring complete dewatering, extensive excavation, and the construction of a new concrete aeration basin equipped with a flow splitting structure, air lines, diffusers, a mixing system, surface wasting pumps, and a high flow return pump connected to an adjacent storage pond. Parallel to this, a new blower building with integrated blowers and a dedicated electrical control building will be erected, alongside a separate carbon feed building housing chemical storage tanks and metering pumps. Additional scope includes a below grade secondary clarifier weir flow splitting structure and the relocation of an existing concrete sand filter high flow diversion structure. The project is scheduled to span 482 working days with defined intermediate milestones to ensure progress tracking. The project is funded in whole or part through the U.S. Environmental Protection Agency’s WIFIA program, triggering specific compliance requirements under Section 9 of the Special Provisions that contractors and subcontractors must adhere to. Preference is actively encouraged for participation by Disadvantaged Business Enterprises including DBE, DVBE, MBE, WBE, and SBE, aligning with the SBA’s small business set-aside categories such as Small Business, Small Disadvantaged Business, Women-Owned Small Business, and Minority and Women Business Enterprises certified through NMSDC or similar programs. The solicitation was posted on August 7, 2026, with a response deadline of September 3, 2026, and although the pre-bid conference occurred on January 14, 2026, contract documents are accessible online through BuildingConnected and the Town of Windsor’s official bids portal after completing a brief registration form. The contracting entity is C. Overaa & Co., with Anna Stein listed as the primary point of contact for inquiries.
C. Overaa & Co.

POSTED

about 6 hours ago

DEADLINE

in 26 days
View Details
NAICS: 236220
New
Vehicle Maintenance Shop #71 Fort Hood, Texas
Solicitation # vehicle-maintenance-shop-71-fort-hood-texas
Cerris Builders, INC is soliciting bids for the construction of Vehicle Maintenance Shop #71 at Fort Hood, Texas, with a focus on delivering a fully equipped facility to support military vehicle maintenance and operational readiness. The project encompasses a large-scale maintenance facility designed for tactical and organizational vehicles, along with dedicated spaces for UAV storage and maintenance, petroleum and hazardous material handling, and comprehensive storage solutions. The scope further includes critical infrastructure such as fire protection and alarm systems, intrusion detection systems, and an Energy Monitoring Control System to ensure safety, security, and operational efficiency. Supporting site improvements are required, including utilities, storm drainage, paved surfaces, sidewalks, lighting, signage, fencing, and landscaping to complete the site to full operational standards. The solicitation is set aside exclusively for small business concerns, including Small Disadvantaged Businesses, Women-Owned Small Businesses, HUBZone, Veteran-Owned, and Service-Disabled Veteran-Owned Small Businesses, reflecting a commitment to fostering diverse contracting opportunities. The response deadline for submissions is August 11, 2026, with Drake Martin serving as the primary point of contact for inquiries.
Cerris Builders, INC

POSTED

about 6 hours ago

DEADLINE

in 3 days
View Details
NAICS: 236220
New
SLED
Construction Manager at Risk for New Precinct 4 Maintenance Center
Solicitation # F2027007
Tarrant County is soliciting proposals for a Construction Manager at Risk (CMAR) to manage the construction of the New Precinct 4 Maintenance Center at 1005 Scotland Avenue in Azle, Texas. The project involves building an Administration Building, Maintenance Building, Fleet Building, Covered Storage, Fuel Island, and Covered Parking Areas, with the selected CMAR assuming full risk for construction costs and timelines while acting as the general contractor. The CMAR will provide expert consultation during design adjustments and throughout construction, ensuring compliance with all technical specifications and legal requirements. The selection will occur through a one-step process, emphasizing both technical capability and cost competitiveness. The technical design and engineering for the project are led by Parkhill for architectural, landscape, structural, MEP, and interior design, with McAdams handling civil engineering, WJHW, Inc. for audio/video systems, and Datacom Design Group for IT and security infrastructure. Proposals must be submitted by September 17, 2026, following the solicitation issued on August 7, 2026 under reference number F2027007 and classified under NAICS code 236220. Interested firms should review all documents under the “Attachments” tab and attend the Pre-Proposal Conference and Site-Walks listed under the “Activities” tab. Direct questions to Gwen Peterson, Senior Buyer, at gpeterson@tarrantcountytx.gov or 817-884-1145.
Tarrant County

POSTED

about 8 hours ago

DEADLINE

in about 1 month
View Details
NAICS: 236220
New
SLED
Rail RFI Engine House Construction
Solicitation # BD-27-1030-0T100-0T281-132125
The Massachusetts Department of Transportation Rail and Transit Division is seeking industry input through a Request for Information to inform the future procurement process for constructing the Hyannis Engine House. This solicitation, identified as BD-27-1030-0T100-0T281-132125, was posted on August 7, 2026, with responses due by August 25, 2026, and is aimed at gathering technical expertise and market feedback from qualified vendors to shape the scope, requirements, and approach of a potential upcoming bid. While no specific set-aside or NAICS code is currently defined, the initiative is classified under state and local government procurement and is managed by the MassDOT Rail and Transit Division based in Boston, Massachusetts. The primary point of contact for this RFI is Monica Auguste, designated as the Purchaser, and all submissions must be directed through the official CommBuy portal linked in the notice. The place of performance for the eventual construction is expected to be in Hyannis, though the agency’s administrative address for this solicitation is listed as Park Plaza in Boston, with a zip code of 02116. This RFI does not constitute a commitment to procure but is a critical step in gathering insights to ensure the future solicitation aligns with current industry capabilities, technologies, and best practices for rail infrastructure development.
0T100 - RAIL AND TRANSIT

POSTED

about 9 hours ago

DEADLINE

in 18 days
View Details
NAICS: 236220
New
Federal
Z1DA--| SOL| NRM| 646-21-101 UD SPS AHU & RO Upgrade Construction (VA-26-00036217)
Solicitation # 36C24426R0139
This is an unrestricted construction solicitation under FAR Subpart 15 for the UD B1 SPS AHU & RO Upgrade project at a Department of Veterans Affairs facility in Pittsburgh, Pennsylvania, with a NAICS code of 236220 and an estimated value between $10 million and $20 million. The scope includes comprehensive architectural and engineering services to upgrade air handling and reverse osmosis systems, overhaul backup power infrastructure, remove ethylene oxide abator equipment, add a second cart wash, separate SPS and SPD operational spaces, install visible and audible alerts, renovate finishes and lighting, reinforce and lower slabs under cart washers, and develop satellite SPS spaces on upper floors. All work must comply with VA Handbook 7610, the VAPHS Master Space Plan, The Joint Commission standards, ANSI/AAMI ST79:2017, AAMI TIR34:2014(R)2017, and ANSI/AAMI ST91:2021 for endoscope processing, while adhering to ADA accessibility requirements. The period of performance is 720 calendar days from receipt of the Notice to Proceed. The contract enforces strict compliance with technical and administrative requirements, including mandatory pre-approval of all equipment and materials by the Government prior to delivery, with all items to be delivered and stored in original sealed manufacturer packaging clearly labeled with OEM name, model, catalog, and serial numbers. Packaging must protect against damage, moisture, dirt, cold, and rain, and specialty items like paints and coatings must include batch numbers, safety instructions, and federal specification numbers. Submittals must follow the exact sequence of the specifications, and offerors must submit a point-by-point compliance statement indicating “DOES NOT COMPLY” or “COMPARABLE” with full descriptions for alternatives; failure to do so will result in disqualification. Payment is governed by FAR 52.232-5, requiring monthly AIA G702 and G703 forms, a satisfactory progress schedule update, and electronic submission via the VAFSC Tungsten Network after CO and COR signature. The contractor must maintain a full-time CQC team on-site and provide a Safety and Occupational Health program aligned with USACE EM 385-1-1 and OSHA regulations, including designated Safety and Health Managers, Site Safety and Health Officers, and specialized Competent Persons for high-risk activities. All personnel require VA pre-approval
244-NETWORK Contract Office 4 (36C244)

POSTED

about 10 hours ago

DEADLINE

in 20 days
View Details
Fairmount Avenue Fire Station - California | CLEATUS