Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, October 14 at 2:00 PM ET

Register Free →

Fire Alarm System Lead Installer/Integrator

Active
State & Local

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

AI Contract Overview

Show more

This subcontract for a Fire Alarm System Lead Installer/Integrator involves the installation, programming, and integration of fire alarm systems for Boone County Property Maintenance projects. The scope of work includes installing one Fire Alarm Control Panel and three Remote Annunciators, configuring the necessary system software, and integrating the system with smoke evacuation to ensure rooftop HVAC units are overridden for cell block exhaust. The contractor is responsible for conducting all pre-testing and coordinating the final inspection with the Authority Having Jurisdiction to deliver a fully certified operational system. Due to the nature of the secure facility, all personnel are required to undergo background checks for access. This opportunity was posted on October 5, 2026, with a response deadline of October 19, 2026. The project falls under NAICS code 238210 and is managed through the Kentucky Property Maintenance agency.

General Info

Install, program, and integrate fire alarm systems for Boone County Property Maintenance projects.

Documents

This scope was carved out of BCFY27-15.

The full solicitation package (4 documents), including the RFP, is on the prime solicitation, not on this scope.

View the prime solicitation

Boone County Jail Fire Alarm Replacement

AI Contract Breakdown

Uniform Contract Format

No documents to break down

The breakdown needs solicitation documents. None were found from this contract's source.

Timeline

Posted

subcontract

Response Deadline

Submission deadline

Response Deadline

Ready to pursue this opportunity?

Start your free trial to track this contract, build proposals with AI assistance, and manage your pipeline.

Organization & Contact Information

Show more
AgencyKentucky → Property Maintenance
ContactsNo contacts available
OfficeN/A
Office AddressN/A
ContactsNo contact information available

Full Description

Show more
Installs, programs, and integrates fire alarm systems for prime contractors on Boone County Property Maintenance projects. Installs one Fire Alarm Control Panel and three Remote Annunciators, configures system software, and integrates the system with smoke evacuation to override rooftop HVAC units for cell block exhaust. Performs pre-testing and final AHJ inspection. Requires background checks for secure facility access. Delivers an AHJ-certified operational system.

Similar Contracts

Same NAICS industry code

More opportunities from Kentucky → Property Maintenance

Same awarding agency

NAICS: 238210
SLED
Boone County Jail Fire Alarm Replacement
Solicitation # BCFY27-15
Solicitation BCFY27-15 seeks proposals for the replacement of the fire alarm system at the Boone County Jail in Burlington, Kentucky. Because the facility is a secure, 24/7 environment housing over 400 detainees, the project requires a phased implementation that allows for the simultaneous operation of old and new systems. The scope includes the installation of a fire alarm control panel, three remote annunciators, 326 smoke detectors, 40 heat detectors, 24 duct smoke detectors, and various relay and monitor modules. A critical technical requirement is the integration of a smoke evacuation system that overrides rooftop HVAC units to exhaust cell blocks during fire events. Additionally, all wiring in laundry and shower areas must be in conduit, and wireless devices are strictly limited to the meter pit tamper switch. Proposals must be submitted electronically by October 19, 2026, at 2:00 pm local time. Award recommendations will be based on the best interest of the County, with evaluation weighted equally across project understanding, timeline and approach, proposed price, and overall proposal quality. Required submittals include a cost proposal, a narrative addressing RFP elements, a W-9, and certificates of insurance. The successful contractor must provide a two-year warranty on parts and workmanship, conduct a system pretest and a final inspection with the Authority Having Jurisdiction, and ensure all contractors undergo background checks and adhere to strict tool controls. Insurance requirements include statutory workers compensation and a two million dollar umbrella/excess liability policy.
Electrical Contractors and Other Wiring Installation Contractors

POSTED

9 days ago

DEADLINE

in 6 days
View Details

Ready to Pursue This Opportunity?

Get AI-powered intelligence on this solicitation and the ones like it

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS