Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, October 28 at 2:00 PM ET

Register Free →

This Government Contract opportunity from California was posted on June 24, 2026. The submission period has ended. Browse the details below for market research, or find similar active opportunities.

Fire and Life Safety Systems Design

Closed
State & Local

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

Active Opportunities Like This One

NAICS: 541330
New
SLED
Orange County Managed Lanes Segment Advancement Study C265256
Solicitation # C265256
The Orange County Transportation Authority is soliciting professional services for the Orange County Managed Lanes Segment Advancement Study, a project with an estimated budget of 350,000 dollars and a duration of 18 months. The primary objective of the study is to evaluate existing, planned, and potential managed lane facilities to identify priority segments ready to advance into the Project Initiation Document phase. The work is structured into four key tasks: project management and coordination, segment inventory and screening, priority segment advancement assessment for up to two segments, and the delivery of a final study report with technical appendices. This is a firm fixed price contract requiring the consultant to provide designated key personnel and adhere to Level 1 Health, Safety, and Environmental specifications, including compliance with CCR Title 8. Invoicing occurs on a monthly basis, with payments remitted within 30 calendar days of approval, and final acceptance is contingent upon the release of retention. Proposals must be submitted electronically via the OpenGov portal by November 30, 2026, and must include a detailed cost proposal across the four specified tasks. Consultants are also required to disclose any conflicts of interest and may be required to file Statements of Economic Interest.
Planning-Planning & Analysis

POSTED

about 14 hours ago

DEADLINE

in about 1 month

AI Contract Overview

Show more

The Fullerton Joint Union High School District in California is seeking a subcontractor for the Fire and Life Safety Systems Design project. The scope of work involves the comprehensive design of fire alarm systems and Emergency Voice Alarm Communication Systems, including the strategic placement of devices, development of circuit layouts, and the performance of critical voltage-drop calculations. All designs must strictly adhere to NFPA 72 standards and applicable California building and fire codes. This opportunity is categorized under NAICS code 541330 and is located in Fullerton, California. The solicitation was posted on June 24, 2026, with a response deadline of July 16, 2026. Interested parties can find further details and submission guidelines through the BidAmerica portal.

General Info

Fullerton Joint Union High School District seeks fire and life safety systems design subcontractor.

Place of Performance

Fullerton, CA, 92833, USA

Set-Aside

NONE

Documents

This scope was carved out of 2526-07.

The full solicitation package (2 documents), including the RFP, is on the prime solicitation, not on this scope.

View the prime solicitation

La Habra High School – Sports Fields Upgrade and Campus Modernization

AI Contract Breakdown

Uniform Contract Format

No documents to break down

The breakdown needs solicitation documents. None were found from this contract's source.

Timeline

PhaseClosed
Posted

subcontract

Response Deadline

Deadline has passed

Submission Closed

Find active opportunities like this

Get full access to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyCalifornia → Fullerton Joint Union High School District
ContactsNo contacts available
OfficeN/A
Office AddressN/A
ContactsNo contact information available

Full Description

Show more
Design fire alarm systems, EVAACS, device placement, circuit layouts, and voltage-drop calculations in compliance with NFPA 72 and California codes.

Earlier notices in this NAICS code

Posted before this notice, open and closed

Find Active Opportunities Like This

Get AI-powered intelligence on the opportunities still open

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS