Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, November 11 at 2:00 PM ET

Register Free →

This Government Contract opportunity from Department Of Defense was posted on September 28, 2020. The submission period has ended. Browse the details below for market research, or find similar active opportunities.

Fluorescent Inspection System

Awarded
W50S8E20Q0004Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

Active Opportunities Like This One

NAICS: 334519
New
SLED
RFID Stick Readers
Solicitation # 554-27-003
The Texas Animal Health Commission is soliciting bids under solicitation number 554-27-003 for the procurement of low frequency RFID stick readers for livestock applications. The required equipment must include the RFID stick reader, a rugged padded case, a USB data transfer cable, and a charging cable with an adapter, with the capability to display multiple types of data simultaneously. This is an Invitation for Bids (IFB) process, typically awarding to the lowest responsive and responsible bidder. Bids must be submitted in a sealed envelope to the Purchasing Department in Austin, Texas, by 2:00 p.m. Central Time on December 3, 2026. Electronic or facsimile submissions will be rejected, and failure to properly label the envelope or complete the Information and Certifications Form will result in disqualification. The contract is governed by the laws of the State of Texas and the Texas Government Code. Award is expected in December 2026, with payments processed within 30 days of satisfactory delivery in accordance with the Texas Prompt Payment Act. Vendors must certify compliance with various state and federal regulations, including HUB status, antitrust laws, and cybersecurity training requirements. The Texas Animal Health Commission maintains the authority to monitor performance through document reviews and on-site audits, providing a ten-day window for corrective action if non-compliance is identified. Primary administrative and bidding contact is Bryan Krugman.
Texas Animal Health Commission

POSTED

about 21 hours ago

DEADLINE

in about 1 month

AI Contract Overview

Show more

Solicitation W50S8E20Q0004 is a Request for Quote issued by the 106th Rescue Wing of the New York Air National Guard for the procurement of one Fluorescent Inspection System. This equipment must be a Size 5, designation PT-48, with a frame measuring 48 inches long by 34 inches wide by 36 inches high and a minimum usable tank size of 43 inches long by 29 inches wide by 26 inches deep. The system is intended for general purpose stationary inspection and must align with the modular workstation requirements outlined in T.O. 33B-1-1 Chapter 2, Section III, potentially including dip tanks, rinse stations, and inspection booths. This procurement is classified as a 100 percent set-aside for small business concerns under NAICS code 334519, with a business size standard of 500 employees. The contract will be awarded as a Firm Fixed Price agreement. It is governed by FAR Subpart 12.6 and Simplified Acquisition Procedures under FAR 13, incorporating provisions and clauses effective through FAC 2020-08. Performance will take place in Westhampton Beach, New York.

General Info

Contract Value

$95,500

NAICS

334519 - Other Measuring and Controlling Device Manufacturing

Place of Performance

Westhampton Beach, NY, 11978, USA

Set-Aside

SBA

Awardee

NEWCO INC

Award Issued Date

Documents

4

MIL-PRF-32531.pdf

PDF

Request+for+Information+1.pdf

PDF

Request+for+Information+4+and+5.pdf

PDF

Request+for+Information+6+and+7.pdf

PDF

AI Contract Breakdown

Uniform Contract Format

Contract not broken down yet

CLEATUS splits the solicitation into Uniform Contract Format (UCF) sections: scope, pricing, deliverables, and evaluation criteria.

Timeline

4 updates
PhaseAwarded
Posted

Combined Synopsis

Notice updated

The notice description changed.

Notice updated

Notice details unchanged. Attachments may have changed.

Notice updated

The point of contact changed.

Notice updated

Notice details unchanged. Attachments may have changed.

Awarded

Contract was awarded

Submission Closed

Find active opportunities like this

Get full access to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyDepartment Of Defense → W7NR Uspfo Activity Nyang 106
Contacts2 people available
OfficeWESTHAMPTON BEACH, NY, 11978-1201, USA
Office AddressWESTHAMPTON BEACH, NY, 11978-1201, USA

Full Description

Show more
This is a COMBINED SYNOPSIS/SOLICITATION for commercial items prepared in accordance with the information in FAR Subpart 12.6, using Simplified Acquisition Procedures found at FAR 13, as supplemented with the additional information included in this notice. The announcement constitutes the only solicitation; a written solicitation will not be issued. The solicitation number is W50S8E20Q0004 and is issued as a Request for Quote (RFQ). This solicitation documents and incorporates provisions and clauses in effect through FAC 2020-08, effective August 13, 2020. It is the responsibility of the contractor to be familiar with the applicable clauses and provisions. The clauses may be accessed in full text at these addresses: https://www.acquisition.gov/far/ and http://www.acq.osd.mil/dpap/dars/dfarspgi/current/index.html. The NAICS code is 334519 and the Small Business Standard is 500 employees. Please identify your business size in your response based on this standard. This procurement is classified as 100% set aside for small business concerns. The Small Business Office concurs with the set-aside decision. The 106th Rescue Wing of the New York Air National Guard requests responses from qualified sources capable of providing a Fluorescent Inspection System. 01 EACH: Fluorescent Inspection System- Size 5, designation PT-48, Frame Size 48" long x 34" wide x 36" height, minimum usable tank size 43: long x 29" wide x 26" deep. Stationary Inspection Equipment - General Purpose. The type of equipment most frequently used in fixed installations consists of a series of modular workstations. At each station an inspector performs a specific task. The number of stations in a processing line varies with the type of penetrant method used. A penetrant line will typically have the following stations: - Penetrant dip tank. - Emulsifier/remover (Methods - B and - D) dip tank. (This station is not applicable for Method - A Method'D systems SHOULD include a rinse station prior to the remover tank.) - Rinse station with UV-A lamp. - Developer tank (if liquid is used). - Drying oven. - Developer tank (if dry-powder is used). - Inspection booth with UV-A lamp. T.O. 33B-1-1 Chapter 2, Section III liquid penetrant inspection equipment. This procurement will be issued as a Firm Fixed Price (FFP) contract.

More opportunities from Department Of Defense → W7NR Uspfo Activity Nyang 106

Same awarding agency

NAICS: 238210
New
Federal
106 CE ELECTRICAL LOOP REPAIR
Solicitation # W50S8E27QA001
Solicitation W50S8E27QA001 is a 100 percent Small Business set-aside for a firm-fixed-price contract to repair the medium voltage electrical loop at Francis S. Gabreski Air National Guard Base in Westhampton Beach, New York. The project, identified as Project WKVB179041, requires the contractor to provide all engineering, labor, equipment, and materials to verify the active parts of the 13.8 kV medium voltage loop feeder and connect the existing line to a second feed at the transformer supporting Building 395. This work is intended to eliminate a single point of failure and ensure loop continuity. The period of performance is seven calendar days upon mobilization, and the contractor must provide a standard one-year construction workmanship warranty. The government will award the contract based on the Lowest Price Technically Acceptable (LPTA) method, utilizing a pass/fail evaluation for technical capability and a fairness and reasonableness review of the price for CLIN 0001. Key requirements include providing a 72-hour notice prior to any electrical outages and adhering to strict installation security and access protocols, including DBIDS vetting and the display of visitor badges. All work must comply with NEC, NFPA, OSHA, and UL standards, as well as New York state specifications. Invoicing shall be processed through Wide Area Workflow (WAWF), and labor must adhere to the specified New York Davis-Bacon wage determinations for Nassau and Suffolk Counties.
Electrical Contractors and Other Wiring Installation Contractors

POSTED

1 day ago

DEADLINE

in 7 days
View Details

Earlier notices in this NAICS code

Posted before this notice, open and closed

Find Active Opportunities Like This

Get AI-powered intelligence on the opportunities still open

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS