THIS IS A SOURCES SOUGHT NOTICE FOR INFORMATION AND ACQUISITION PLANNING PURPOSES (SMALL BUSINESS CONCERNS ONLY). This is not a request for quote or proposal. This notice does not constitute a commitment by the Government to issue an RFP, RFQ, contract or order. The Government will not pay for any effort expended or any material provided in response to this announcement. Requests for a solicitation will not receive a response. This Sources Sought Notice is being issued by the General Services Administration for roof and envelope repairs which will include design services for the U.S. Courthouse in Ft. Myers, Florida. See project summary below. A determination by the Government not to compete this requirement based upon responses to this notice is solely within the discretion of the Government. This notice seeks information to assist the Government in locating potential sources with the ability to satisfy this requirement. Small businesses including business in all socio-economic categories that are certified and qualified under the North American Industry Classification System (NAICS) Code: 236220, Commercial and Institutional Building Construction (Size Standard is $36.5 million) are encouraged to respond. All firms and prime contractors during business with the Federal Government shall be registered in the System for Award Management (SAM) database at www.sam.gov prior to award of a contract. The estimated construction magnitude is between $1,000,000 - $5,000,000 and period of performance for construction is 180 days after Notice to Proceed, plus time allotted for design services. The project award is planned for Spring 2019. If you are an interested firm please provide Written Letter of Interest, Company brochure or literature (if available); and a Response to the following questions (No more than 2 pages) by 12:00 pm EST, January 11, 2019, to Ric J. Sochor via email at ric.sochor@gsa.gov. Note: All information submitted is subject to verification. Additional information may be requested to substantiate responses. Questions: 1. Is your firm a small business? Is your firm a certified 8(a), woman-owned, SDVOSB, or any other socio-economic category? 2. Is your firm capable of providing the scope of work described in the project summary below? Note: Provide a listing of similar projects performed in the past 5 years demonstrating successful completion of commercial roofing, window replacements, building envelope repairs/waterproofing and professional design services. The firm may provide evidence of past performance from the subcontractor / consultants for their design-build team proposed for this project. 3. Does your firm have a professional design capability to perform the window survey and design? Please provide name of design firm. The written Letter of Interest must contain the following elements at a minimum: 1. Contractor's name, address, point of contact, phone number and email address. 2. Tax Identification Number and DUNS no. 3. North America Industry Classification System (NAICS) code(s) under which the company operates. 4. Contractor's Bonding Capacity. The Government will review each response and will use the information it receives in response to this sources sought notice a basis for determining whether there exists reasonable expectation of obtaining a sufficient number of offers that are competitive in terms of market prices, quality and delivery. Contracting Office Address: U.S. General Services Administration (GSA) Public Buildings Service (PBS) Design & Construction Florida Branch AMD (4PQF) 501 E. Polk Street, Suite 805 Tampa, Florida 33602 Place of Performance: Ft. Myers, Florida Primary Point of Contact.: ric.sochor@gsa.gov Phone: 813 316-5307 Project Summary: Building Enclosure Repairs and Improvements at the existing 7 story Ft. Myers U.S. Courthouse in Ft. Myers, Florida. The work includes new waterproofing coatings over existing roof membranes (approximately 33,000 square feet), new roof and wall flashing (approximately 4,400 square feet), new metal parapet copings (approximately 2,400 linear feet), new single ply TPO roof cover (approximately 1,250 square feet), new gutters and downspouts (approximately 170 linear feet), new roof access ladder (1 ladder), third party testing of roof improvements, replacement of EIFS with new drainable EIFS (approximately 15,000 square feet), stucco patch and repair work (approximately 2,600 square feet), crack and spall repairs at concrete columns in penthouse (approximately 13 square feet at 5 locations), new doors and associated hardware in penthouse (7 doors), replacement of sealant throughout the building enclosure, third party survey of exterior windows (approximately 270 windows), third party water testing of exterior windows (18 windows), repair and replacement of exterior windows (per unit price), cleaning of all exterior building surfaces (approximately 108,000 square feet), interior painting in the penthouse (approximately 5,000 square feet), new metal wall louvers (2 louvers), replacement of clay tile pavers (approximately 50 square feet), lighting protection system repairs and UL Master Label Re-certification, and other minor electrical work.