Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, October 28 at 2:00 PM ET

Register Free →

This Sources Sought opportunity from Department Of Veterans Affairs was posted on October 23, 2025. The submission period has ended. Browse the details below for market research, or find similar active opportunities.

H165--FY26 - Annual Calibration of the Hospital's Survey Meters (B+4)

Closed
36C24226Q0078Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

Active Opportunities Like This One

NAICS: 541690
New
International
Archaeology Consulting Services
Solicitation # 26-122
The City of Delta is issuing solicitation 26-122 to establish a shortlist of qualified archaeology firms to provide professional consulting services on an as-and-when-requested basis. The scope of work includes archaeological investigation, monitoring, reporting, and permitting for various infrastructure and development projects, such as road upgrades and utility replacements, within the City of Delta. All services must comply with the Heritage Conservation Act, and firms must demonstrate eligibility to hold provincial permits, including Multi Assessment Permits and Site Alteration Permits. Key deliverables involve field assessments, coordination with the Provincial Archaeology Branch and First Nations, and the provision of heritage management training for City staff. The selection process utilizes a two-stage qualification method. To be considered, respondents must meet all mandatory criteria, including the timely submission of a signed Proposal Covering Letter. Qualified firms will be evaluated based on proponent capability and experience (50%), methodology (25%), and fees (25%), with minimum scores required for the first two categories. The City emphasizes the importance of professional certification, requiring at least one team member to be in good standing with a recognized organization like the British Columbia Association of Professional Archaeologists. Preference is given to consulting team members with five years of experience and lead archaeologists with ten years of experience. The resulting shortlist will remain valid until January 1, 2025, or for three years from the closing date. Once the list is established, the City will invite these qualified respondents to submit firm-priced tenders for specific projects. Proposals must be submitted as a single PDF to the purchasing department by 2:00 PM Pacific time on November 16, 2026. The pricing structure for the qualification stage includes hourly rates for principal archaeologists, field directors, technicians, and support staff, as well as lump sum rates for permit applications.
City of Delta

POSTED

1 day ago

DEADLINE

in 26 days

General Info

NAICS

541690 - Other Scientific and Technical Consulting Services

Place of Performance

800 Poly Place, NY, 11209, USA

Set-Aside

NONE

Documents

1

Solicitation 36C24226Q0078 - FY26 Annual Calibration of Hospital Survey Meters

DOCX, High priority: read this first6 pages · rfp
High

AI Contract Breakdown

Uniform Contract Format

Sign up to view the full breakdown with detailed analysis of each section.

Timeline

PhaseClosed
Posted

Sources Sought

Response Deadline

Deadline has passed

Submission Closed

Find active opportunities like this

Start your free trial to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyDepartment Of Veterans Affairs → 242-NETWORK Contract Office 02 (36C242)
Contacts1 person available
OfficeALBANY, NY, 12208, USA
Office AddressALBANY, NY, 12208, USA
Contacts
Lisa HarrisContract Specialist

Full Description

Show more
Calibration of the Hospital Survey Meters

More opportunities from Department Of Veterans Affairs → 242-NETWORK Contract Office 02 (36C242)

Same awarding agency

NAICS: 811210
New
Federal
J065- Q2 SERVICES (BASE+4) Globus NYH Service Contract (VA-27-00004429)
Solicitation # 36C24227Q0068
The Department of Veterans Affairs Network Contracting Office 2 intends to award a sole source contract to Globus Medical, Inc. for the annual preventative maintenance, corrective maintenance, and repair of proprietary Global Surgical Equipment. This includes the ExcelsiusGPS robotic system and ExcelsiusE3D system. The services will be performed at the VA New York Harbor Healthcare System's Manhattan and Brooklyn campuses. The base period of performance is scheduled from January 1, 2027, to December 31, 2027, with the possibility of four additional option years. The procurement falls under NAICS code 811210 for Electronic and Precision Equipment Repair and Maintenance, which has a small business size standard of 34 million dollars. It is noted that Globus Medical, Inc. has an exclusive authorized Service-Disabled Veteran Owned Small Business partner, SDV Office Systems, LLC, for sales of this equipment to federal government facilities. While this is a notice of intent for a sole source award, interested firms may submit written notification and supporting evidence of their ability to perform the requirements to Kaitlyn Morgan via email by October 27, 2026, at 12:00 p.m. EST. The government maintains sole discretion on whether to compete the procurement based on the responses received.
Electronic and Precision Equipment Repair and Maintenance

POSTED

about 6 hours ago

DEADLINE

in 6 days
View Details
NAICS: 238220
New
Federal
W045--Boiler Rental
Solicitation # 36C24227Q0042
The Department of Veterans Affairs is seeking a firm-fixed price contract for the temporary rental, installation, and maintenance of a fire tube steam boiler at the VA Hudson Valley Healthcare System Montrose Campus. The period of performance is scheduled from November 1, 2026, through March 31, 2027, with a required installation date of November 1, 2026, and a ready-for-service date of December 1, 2026. The equipment must be an 800 HP unit capable of a 95 PSI operating pressure to support a historical peak steam load of 120,000 lb/hr. While a 9 PPM NOx requirement is listed, the government has indicated that a unit rated at 30 PPM NOx is acceptable to ensure the delivery schedule is met. The government will furnish the fuel, and the boiler will be located on the east side of the plant. The contractor is responsible for providing approximately 200 feet of 6-inch diameter piping, supports, valves, and fittings for boiler feedwater, as well as independent controls to monitor key parameters and emergency stop capabilities. Maintenance requirements include a minimum of 10 hours of monthly service and the submission of two internal inspection reports, one prior to delivery and one at the end of the rental period. Compliance with the VHA Safety Device and Testing Manual is mandatory, and the vendor must obtain all necessary hot work and confined space permits. This is a total small business set-aside under NAICS 238220. Award evaluations will be based on a combination of price and technical factors, including past performance, with technical and past performance weighted equally to price.
Plumbing, Heating, and Air-Conditioning Contractors

POSTED

1 day ago

DEADLINE

in 29 minutes
View Details
NAICS: 621511
New
Federal
Q301--FY27 (BASE+4) STAT Laboratory Testing - Syracuse (VA-27-00010334)
Solicitation # 36C24227Q0069
The Department of Veterans Affairs VISN 2 Network Contracting Office intends to award a firm fixed-price contract for STAT laboratory testing services at the Syracuse VA Medical Center. The proposed contract structure includes a base period followed by four option periods. The government intends to sole source this requirement to University Pathologists Laboratories under FAR 6.302-1(a)(2), though this special notice serves as market research to identify other capable providers, including various small business socioeconomic categories. The scope of work involves the 24/7, 365-day-a-year analysis, monitoring, and reporting of clinical and surgical specimens, utilizing advanced methods such as electron microscopy and molecular studies. Key operational requirements include picking up specimens within 30 minutes of a request and delivering final written reports within five working days. Critical results require immediate notification to authorized providers. To be eligible, the contractor must employ board-certified pathologists and accredited technologists and maintain mandatory certifications, including a NYS Department of Health Clinical Laboratory Permit, a CLIA license, and CAP or Joint Commission accreditation. This acquisition falls under NAICS code 621511. Interested parties must provide documentation of their technical expertise and socioeconomic status to the contracting officer within 10 calendar days of the notice publication.
Medical Laboratories

POSTED

1 day ago

DEADLINE

in 9 days
View Details
NAICS: 541330
New
Federal
C1DA--NRM A/E- 528A7-27-112 Fire Alarm Panel Upgrade
Solicitation # 36C24227Q0070
The Department of Veterans Affairs, through Network Contracting Office 02, has issued a Request for Information to identify qualified Architect-Engineer firms for the upgrade of an obsolete Edwards EST-3 fire alarm system at the Syracuse VA Medical Center in New York. This is a sources sought notice and not a formal solicitation for proposals. The scope of work involves providing complete design and cost estimation services, including the upgrade of fire alarm control panels and remote annunciators, the installation of a new master control panel and fiber loop network, the expansion of the addressable system to additional campus buildings, and the removal of the existing fireman telephone system. The selected firm must also develop a phasing plan to ensure continuous fire alarm protection during construction and provide construction period services. A critical requirement for this project is that the prime firm must have a registered Fire Protection Engineer (FPE) on staff, and all drawings must be stamped by an FPE with no exceptions. All designs must comply with the latest editions of NFPA 70, NFPA 72, and the NEC, as well as applicable VA construction standards and fire protection design criteria. This opportunity falls under NAICS code 541330 for Engineering Services. Interested and capable sources must submit a written capability statement to the designated contract specialist by November 3, 2026, at 10:00 EST.
Engineering Services

POSTED

1 day ago

DEADLINE

in 13 days
View Details

Find Active Opportunities Like This

Get AI-powered intelligence on the opportunities still open

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS