Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, November 11 at 2:00 PM ET

Register Free →

This Sources Sought opportunity from Department Of Veterans Affairs was posted on April 23, 2020. The submission period has ended. Browse the details below for market research, or find similar active opportunities.

H236--Test and Certify Government Owned Labs in Green Bay VA HCC Contract

Closed
36C25220Q0501Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

Active Opportunities Like This One

NAICS: 811310
New
Kubota M8200 Clutch Replacement
Solicitation # kubota-m8200-clutch-replacement
Management & Training Corporation, operator of the Earle C. Clements Job Corps Center in Morganfield, Kentucky, is soliciting bids for the clutch replacement of a Kubota M8200 tractor equipped with front wheel assist and no cab or loader. The contractor is responsible for providing all transportation, labor, supervision, tools, and new manufacturer-specified parts to diagnose and repair the clutch assembly and power take-off system. The scope of work includes disassembling tractor components, replacing friction discs, bearings, oil seals, and O-rings, resurfacing the flywheel, and replacing necessary hydraulic pipes and filters. Final acceptance is contingent upon the Facility Maintenance Department verifying proper clutch engagement and disengagement and confirming the unit is fully operational under load. This is a fee-for-service solicitation based on a lump sum bid, with award determined by best value. Interested offerors must submit a bid sheet, a completed supplier packet including IRS Form W-9 and self-certification, proof of insurance, and any applicable SBA certification letters by November 3, 2026. The contract is set aside for small businesses and incorporates various Federal Acquisition Regulation clauses regarding equal opportunity, minimum wage standards under Service Contract Labor Standards, and restrictions on foreign purchases. Contractors must also comply with strict security and confidentiality protocols regarding non-public information and government facilities.
Earle C. Clements Job Corps Center

POSTED

about 2 hours ago

DEADLINE

in 3 days
NAICS: 811310
New
SLED
Conveyance Maintenance Services
Solicitation # 26-1336
Chicago Public Schools is soliciting bids for Conveyance Maintenance Services under solicitation number 26-1336 to implement a comprehensive preventive maintenance program for conveyance equipment. The selected bidder will provide all labor, materials, and supervision necessary to ensure equipment remains safe and operational, adhering to the City of Chicago Municipal Code, ASME A17.1/CSA B44, ASME A17.3, and original equipment manufacturer standards. The contract includes a three-year initial term with the possibility of two automatic renewals of two years each. Services involve monthly preventive maintenance during normal working hours from 6:00 a.m. to 2:30 p.m., as well as 24/7 emergency callback support. Key deliverables include site-specific maintenance schedules, the use of CPS facilities software for reporting, and an annual Executive Summary Report based on a 7-point assessment rubric. The agreement will be awarded to the lowest, responsive, and responsible bidder based on evaluation factors including price, business stability, professional qualifications, past performance, and capacity. Bidders must submit a comprehensive package via Bonfire, including an Excel-based bid tabulation, audited financial statements for the last three fiscal years, three non-Board references, and a W-9 tax form. Compliance with MBE/WBE aspirational goals of 30% and 7% respectively is required, along with adherence to the Illinois Minimum Wage Law and various federal and state non-discrimination acts. Invoicing must be submitted electronically in PDF format, with payments processed according to the Local Government Prompt Payment Act. All shipments are designated as F.O.B. destination. The deadline for questions is November 6, 2026, and the final response deadline is November 20, 2026.
Chicago Public Schools

POSTED

1 day ago

DEADLINE

in 19 days
NAICS: 811310
New
SLED
Annual Inspection/Maint. and Repair on Generator at FMS #8
Solicitation # SRC0000037488
Solicitation SRC0000037488 is for the annual inspection, maintenance, and repair of a Speed Air air compressor (Model 1WD44, SN: D063475) at FMS #8 in Gadsden, Alabama. The scope of work includes replacing belts, collecting oil samples, and installing filters, cabinet filter mats, and repair kits for the oil and thermostatic valves. A mandatory site visit is required on November 18, 2026, at 10:00 AM at 5319 Airport Road, Gadsden, Alabama. The response deadline is November 23, 2026, and all bids must be submitted electronically through the Alabama Buys portal. The contract is managed by the Army MCA and the State of Alabama, with a maximum total value of 25,000 dollars over a potential five-year period, subject to annual renewals. Award evaluation will be based on price reasonableness, cost realism, and supplier qualifications, including professional licenses and insurance. Vendors must comply with the Code of Alabama, including the Beason-Hammon Alabama Taxpayer and Citizen Protection Act and registration requirements for foreign corporations. Payment will be handled electronically via P-cards, EFT, or state-issued credit cards. Final acceptance of services is contingent upon a satisfactory inspection by the State of Alabama in accordance with the Universal Commerce Code.
Army MCA_App 01_Real Property Operations & Maintenance, State Military Department

POSTED

1 day ago

DEADLINE

in 22 days

AI Contract Overview

Show more

This contract requires a qualified contractor to provide all labor, materials, and equipment necessary to test and certify government-owned laboratory hoods, biosafety cabinets, and HEPA bank filters at the Green Bay Health Care Center and the John H. Bradley Appleton VA Clinic. The scope includes semi-annual certifications for biosafety cabinets and pharmacy hoods, including air quality evaluations, particle counts, and microbial testing in accordance with USP 797 and NSF/ANSI-49 standards. Additionally, the contractor must perform annual room pressurization tests for sterile processing, isolation rooms, and OR suites following ASHRAE standards. The contractor must ensure a two-hour telephone response time and a 24-hour on-site response for emergencies. All work must be performed by NSF-certified technicians during regular business hours, with detailed certification reports and equipment stickers provided within 30 days of inspection. The contractor is responsible for providing all necessary personal protective equipment and ensuring all test equipment is calibrated to national standards. Any defects found outside the contract scope must be reported within 24 hours with a cost estimate provided within seven working days.

General Info

Contractor will test and certify laboratory hoods and filters at two VA facilities.

NAICS

811310 - Commercial and Industrial Machinery and Equipment (except Automotive and Electronic) Repair and Maintenance

Place of Performance

Green Bay Health Care Center (HCC), 2851;University Ave Green Bay WI 5431 and the John H.;Bradley Appleton VA Clinic Building 1, WI, 54914

Set-Aside

NONE

Documents

0

No documents available

Documents will appear here when they are available.

AI Contract Breakdown

Uniform Contract Format

No documents to break down

The breakdown needs solicitation documents. None were found from this contract's source.

Timeline

PhaseClosed
Posted

Sources Sought

Response Deadline

Deadline has passed

Submission Closed

Find active opportunities like this

Get full access to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyDepartment Of Veterans Affairs → 252-NETWORK Contract Office 12 (36C252)
Contacts1 person available
OfficeMILWAUKEE, WI, 53214, USA
Office AddressMILWAUKEE, WI, 53214, USA
Contacts

Full Description

Show more
STATEMENT OF WORK GENERAL: Provide all labor, materials, equipment, tools and reports required to test and certify the Government owned laboratory hoods, biosafety cabinets and HEPA bank filters listed below, located at the Green Bay Health Care Center (HCC), 2851 University Ave Green Bay WI 5431 and the John H. Bradley Appleton VA Clinic Building 1, 10 Tri-Park Way Appleton WI 54914. SCOPE: Provide two-hour telephone response time for equipment related telephone inquiries and 24-hour on-site response time for emergency/issue verification. Testing of the biological safety cabinets shall follow current standards set by National Sanitation Foundation (NSF)/ America National Standard (ANS)/( NSF/ANSI-49), the NSF Certification policies for biosafety Cabinetry, and manufacturer specification. All biosafety cabinets shall be certified every 6 months or semi-annually. The operational integrity of the cabinet must be validated before being put into service or after being repaired, relocated or having filters replaced. Testing of all the hoods for Pharmacy Service shall include a semi-annual air quality evaluation (particle count) as outlined in the most recent edition of the United States Pharmacopeia 797 (USP) indicating the ISO classification for the environment within the hood. The testing of these hoods shall also include a semi-annual high-efficiency particulate air (HEPA) filter integrity/leakage test. The rooms in Pharmacy Service used for sterile preparations shall be tested for compliance as outlined in the most recent edition of USP 797. This shall include measurement of air changes per hour as well as a semi-annual air quality evaluation (particle count) as outlined in the most recent edition of USP 797 indicating the International Organization for Standardization (ISO) classification for the environment in the buffer and anteroom zones. Testing of all hoods/units in Pharmacy service, as well as associated rooms, shall include semi-annual microbial testing as outlined in the most recent edition of USP 797. The sterile preparation rooms in Pharmacy Service shall have an annual room pressurization test, in accordance with ANIS/ the American Society of Heating, Refrigerating and Air-Conditioning Engineers (ASHRAE)/ American Society of Heating and Air-Conditioning Engineers (ASHAE); ANSI/ASHRAE/ASHAE Standard 170-2008 or latest version - Ventilation of Health Care Facilities. The isolation rooms in Specialty Clinic and Primary Care Clinic 2 shall have an annual room pressurization test, in accordance with ANSI/ASHRAE/ASHAE Standard 170-2008 or latest version - Ventilation of Health Care Facilities. The rooms in Sterile Processing shall have an annual room pressurization test, in accordance with ANSI/ASHRAE/ASHE Standard 170-2008 or latest version - Ventilation of Health Care Facilities. The OR suites including Cystology shall have an annual room pressurization test, in accordance with ANSI/ASHRAE/ASHE Standard 170-2008 or latest version - Ventilation of Health Care Facilities. The biosafety cabinetry in Pharmacy Service shall include a semi-annual containment leakage test. This is the hood cabinetry used for preparation of cytotoxic or hazardous drugs. The contractor shall document all certifications performed by placing a certification sticker on the certified equipment immediately after certification. The contractor shall document all certifications by providing reports detailing each certification or test performed within 30 days. The contractor shall not be required to go on the roof of the building. The contractor is responsible for providing all contract employees with required personal protective equipment, respiratory protection and an occupational health program to ensure a safe work environment consistent with current Occupational Safety and Health Administration (OSHA) regulations. SERVICE: Service shall consist of one annual or two semi-annual inspections (see Attachment A) for frequency and month(s) required and certifications that the equipment is functioning properly according to manufacturer s specifications. The contractor shall provide all labor, materials, travel, supervision, tools and facilities required for testing and certification of all equipment listed in this contract (See Attachment A) located at the Medical Center. Contractor shall ensure that the equipment functions in conformance with the latest published edition of applicable standards, such as: NFPA 99, UL, NSF/ANSI 49, ASHRAE 110, SAFA, ANSI, OSHA, VA, IEST, ISO, USP, CDRH, etc. Scheduled Work: Scheduled work is required in the performance of this contact shall be performed during the facility regular hours of 8:00 a.m. and 4:30 p.m., excluding federal holidays. The contractor shall notify the COR at least 7 days prior to the normal testing/inspection cycle visit and 8 hours prior to any emergency activities. Federal Holidays observed by the VAMC(s) are: New Years Day Independence Day Thanksgiving Day Presidents Day Martin Luther King Day Labor Day Christmas Day Columbus Day Memorial Day Veterans Day REPORTING REQUIREMENTS: The contractor shall be required to report to the Contracting Officer Representative: Room - 1J009, to check in and verify identification is present and worn by contractor(s). REPORTING REQUIRED SERVICES BEYOND THE CONTRACT SCOPE: The contractor shall immediately, but no later than 24 consecutive hours after discovery, notify the CO and COR of the existence of the development of any defects or repairs outside of the terms and conditions of this contract. The contractor shall furnish the CO and COR with a written estimate of the cost to make necessary repairs within 7 working days. DOCUMENTATION/REPORTS: Certification reports shall include full documentation of service performed. Each report shall include a unique identification of equipment and all readings and measurements found. In addition, each report shall contain a written comment on the visual condition and use of each cabinet and hood. An identifying certification sticker shall be placed on each unit at the time of inspection indicating status of unit. All completed written reports are due within 30 days of final on-site inspection. All preventative maintenance and other repairs shall be done according to the manufacturer s recommendations. Any authorized repairs/maintenance activities mandate only new standard parts by the original equipment manufacture (OEM) to be furnished by the contractor. All parts shall be of current manufacture and shall have full compatibility with the equipment being repaired. PERFORMANCE STANDARDS: All work must be performed by competent technicians, experienced and qualified to work on the listed equipment. Service Technicians conducting inspection, testing and certification of equipment, must be currently certified as a Technical Certifier by the National Sanitation Foundation (NSF). All work must be performed in accordance with commercial practices. Documentation indicating qualifications (CV, certificates, etc.) must be submitted to the COR, prior to initiation of any work on station. APPROVAL OF CONTRACTOR PERSONNEL: The VA reserves the right to refuse employment under this contract or require dismissal from contract work of any contractor employee who, by reason of previous unsatisfactory performance at the VA or for any other circumstance, is considered by the Contracting Officer s Representative and Contracting Officer to be objectionable. TEST EQUIPMENT: Prior to commencement of work on this contract, the contractor shall make available to the COR a copy of the current calibration certification of all test equipment which is to be used by the contractor on the Milo C. Huempfner VA Medical Center and the John H. Bradley Appleton VA Clinic (GB HCC) s equipment. This certification shall also be provided on a periodic basis when requested by the COR. Test equipment calibration shall be traceable to a national standard. All testing and certification equipment must undergo annual calibration by a recognized testing entity (See Attachment A). PROCEDURES: When a deficiency per the requirements of the SOW exists, it shall be brought to the attention of the COR. The COR shall confirm the deficiency by inspection and record results, noting the date and time of inspection of the deficiencies for correction. IDENTIFICATION, PARKING, SMOKING, AND VA REGULATIONS: The Contractor's employees shall wear visible identification at all times while on the premises of the VA facilities. It is the responsibility of the Contractor to park in the appropriate designated parking areas. Information on parking is available from the VA Police. The facility will not invalidate or make reimbursement for parking violations of the Contractor under any conditions. Smoking is prohibited on VA property. Possession of weapons is prohibited. Enclosed containers, including tool kits, shall be subject to search. Violations of VA regulations may result in citation answerable in the United States (Federal) District Court. ATTACHMENT A Annual Services to be done in January Annual Hepa Bank # Hepa filter location Type Model ID Name (Room) HFB 1 2C246 OR 3 HFB 2 2C249 OR 2 HFB 3 2C243 OR 4 HFB 4 2C221 OR 1 HFB 5 2C239 OR 5 HFB 6 2C225 Cysto HFB 7 2C245 Clean Corridor HFB 8 2C233 Clean Core HFB 9 2C237 Clean Corridor HFB 10 1S020 Hood in IV prep HFB 11 1S020 EF-IL Hood in Chemo prep HFB 12 1E024 VAV IV Prep HFB 13 1E024 VAV Chemo Prep HFB 14 1E021 VAV Ante room HFB 15 1D113 Lab HFB 16 1C233 Isolation room HFB 17 2C229 Clean Corridor HFB 18 2C224.1 Clean vestibule HFB 19 1B029 Isolation room Bio Hood 1D113 Nuaire NU-477-400 EE# 77646 Lab Bio Hood 153E Appleton Lab Positive pressure rooms 1G008 Positive pressure SPS 1G011 Positive Pressure SPS 2C225 Positive Pressure Cysto 2C221 Positive Pressure OR #1 2C249 Positive Pressure OR # 2 2C246 Positive Pressure OR # 3 2C242 Positive Pressure OR # 4 2C239 Positive Pressure OR # 5 2C132 Positive Pressure PACU/Recovery Negative Pressure rooms 1B029 Specialty Clinic Neg. Pressure room(Isolation) Neg Pressure room (Isolation) Primary Care Clinic 2 1C233 Neg. Pressure room (Isolation) Neg. Pressure Room (Isolation) SPS 1G025 Neg Pressure (Decon cart washer) SPS Decon cart washer 1G025 SPS 1G020 Neg Pressure SPS Decon scope area 1G020 SPS 1G010 Neg. Pressure SPS Sterilizer Equipment 1G010 SPS 1G023 Neg Pressure SPS Decon SPS 1G006 Neg Pressure SPS Men s Toilet SPS 1G004 Neg Pressure SPS Women s Toilet SPS 1G019 Neg Pressure SPS Women s Toilet SPS 1G017 Neg Pressure SPS Men s Toilet Semi-Annual Services to be done in July Semi Annual Hoods Room Make Model ID Name (Room) IV Prep 1E023 Particle Count Room IV Prep IV Prep 1E021 Particle Count Ante Room Ante Room IV Prep Laminar Baker SG-400 IV Prep IV Prep Particle Count Baker SG-400 IV Prep IV Prep Microbial Air Plates 12 each IV Prep IV Prep Microbial Surface Plates 8 each IV Prep Oncology Hood Biohood Baker NCB-D4 Oncology Prep Particle Count Baker 1E022 Oncology Prep Particle Count Room 1E022 Oncology Prep Microbial Air Plates 12 each 1E022 Oncology Prep Microbial Surface Plates 8 each 1E022 Bio Hood 1D113 Nuaire NU-477-400 EE#77646 Lab Bio Hood 153E Appleton Lab Clean Storage room 150 Appleton ACH and Gradient Clean Storage HFB 12 1E024 VAV IV Prep HFB 13 1E024 VAV Chemo Prep HFB 14 1E031 VAV Ante room

More opportunities from Department Of Veterans Affairs → 252-NETWORK Contract Office 12 (36C252)

Same awarding agency

NAICS: 238210
New
Federal
Z1DA--Upgrade Fire Alarm System Construction 676-22-110
Solicitation # 36C25226B0014-1
Solicitation 36C25226B0014 is a sealed bid procurement issued by the Department of Veterans Affairs for the upgrade of the fire alarm system at the Tomah VA Medical Center in Tomah, Wisconsin. This project, identified as Project 676-22-110, has an estimated magnitude between 5 million and 10 million dollars and is a 100 percent set-aside for Service-Disabled Veteran-Owned Small Businesses (SDVOSB) under NAICS code 238210. The scope of work includes the demolition of existing systems and the installation of a new fire alarm system, with a performance period of 460 calendar days after the Notice to Proceed. Amendment A0003 extended the offer receipt deadline to November 4, 2026, and increased the preconstruction submission period from 20 to 60 days. Key technical requirements include strict adherence to NFPA Life Safety Code, NEC, and VHA Infection Control Risk Assessment (ICRA) standards, with all work areas requiring Class III or Class IV infection control. The contractor must provide a qualified CQC System Manager with a construction management degree and five years of experience, as well as a dedicated Site Safety and Health Officer (SSHO) with OSHA 30-Hour certification. Bidders must submit a bid bond, and the successful awardee will be required to provide performance and payment bonds equal to the full contract value.
Electrical Contractors and Other Wiring Installation Contractors

POSTED

2 days ago

DEADLINE

in about 1 month
View Details

Earlier notices in this NAICS code

Posted before this notice, open and closed

Find Active Opportunities Like This

Get AI-powered intelligence on the opportunities still open

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS