Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, November 11 at 2:00 PM ET

Register Free →

This Solicitation opportunity from Department Of Veterans Affairs was posted on September 24, 2026. The submission period has ended. Browse the details below for market research, or find similar active opportunities.

H244--ME - TRANSFER SWITCH MAINT BASE PLUS 4 - CO (VA-26-00004264) 589-26-3-5329-0002

Awarded
36C25526Q0680Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

Active Opportunities Like This One

NAICS: 811210
New
SLED
Invitation for Bid IFB A261017059 Uninterrupted Power Supply Maintenance and Repair
Solicitation # A261017059
The California Governor's Office of Emergency Services (Cal OES) is soliciting bids for the maintenance and repair of Mitsubishi Uninterrupted Power Supply (UPS) systems located at 601 and 630 Sequoia Pacific Blvd. in Sacramento, California. The scope of work specifically focuses on a Mitsubishi 2033C Series UPS unit and requires the contractor to provide quarterly, semi-annual, and annual preventative maintenance, as well as battery string replacements and technical support during normal business hours. A critical requirement is the ability to provide 24/7 emergency response with a maximum four-hour on-site arrival time. The contractor must hold a valid California C-10 Electrical Contractor License and adhere to Cal/OSHA safety standards, NFPA 70E for arc flash protection, and Lockout/Tagout procedures. The contract period runs from December 1, 2026, through November 30, 2029, with an initial inspection required within 60 days of the award. Award selection is based on the lowest responsive responsible submission, calculated as the grand total of costs for fiscal years 26/27, 27/28, and 28/29. Bidders must submit electronic proposals to the Cal OES contracts unit by November 23, 2026, including all required certifications, a cost sheet, and a bidder declaration. Preferences are available for certified Small Businesses and Disabled Veteran Business Enterprises. Payment is contingent upon the Cal OES Contract Manager's acceptance of services and is subject to the availability of funds under the Budget Act.
Office of Emergency Services

POSTED

1 day ago

DEADLINE

in 15 days
NAICS: 811210
New
SLED
Plotter Repair & Maintenance Contract for HP DesignJet Z6 44-in Postscript Printer
Solicitation # 27-0058-ITQ
Pinellas County Emergency Management is soliciting an Invitation to Quote for a repair and maintenance contract for an HP DesignJet Z6 44-in Postscript Printer. The objective is to replace an expiring Care Pack to ensure equipment integrity and provide for unexpected repairs. The contract covers labor, parts, and two preventative maintenance visits per year, with a requirement for HP service technician certifications. Response times are strictly defined, requiring one business day for emergency repairs and five business days for routine maintenance. Additionally, the contractor must provide toner and bond paper at a discounted rate, with the latter requiring certification that materials meet EPA guidelines. The contract term is for thirty-six months, with an option for two twelve-month extensions. Proposals must be submitted via the OpenGov procurement website by November 19, 2026. Award preferences are given to Pinellas County Certified Small Business Enterprises, particularly for quotes between $25,000 and $150,000. Vendors must provide a certificate of insurance and proof of registration with the Florida Division of Corporations prior to award. The selected contractor must also agree to provide goods and services on a first-priority basis during public emergencies to protect public health and safety.
EMERGENCY MANAGEMENT

POSTED

1 day ago

DEADLINE

in 11 days

AI Contract Overview

Show more

The Department of Veterans Affairs, Network Contracting Office 15, is seeking a service agreement for the full-service support of Automatic Transfer Switches (ATS) at the Harry S. Truman Memorial Veterans Hospital in Columbia, Missouri. The contract encompasses both scheduled preventive maintenance and unscheduled emergent maintenance for a variety of ASCO, Zenith, and Metron transfer switches. The period of performance consists of a base year starting September 28, 2026, with four subsequent option years, extending the total duration through September 27, 2031. Services are to be performed Monday through Friday between 6:00 p.m. and 6:00 a.m., excluding national holidays. The selected contractor must provide manufacturer-certified technicians who are fully qualified through formalized training and hands-on experience. Maintenance must adhere to NFPA 110 standards and manufacturer specifications, including the provision of all necessary PM kits, parts, labor, and travel. Key deliverables include electronic service reports submitted within seven calendar days of work, handwritten notes provided upon departure, and a comprehensive annual condition report. The government will utilize the Lowest Price Technically Acceptable (LPTA) source-selection process, evaluating offerors on a pass/fail basis for technical qualifications and reporting capabilities before awarding to the lowest priced acceptable quote. This procurement is designated as a mandatory set-aside for Service Disabled Veteran Owned Small Businesses (SDVOSB).

General Info

SDVOSB contract for ATS maintenance at Truman Veterans Hospital from 2026 to 2031.

Contract Value

$23,161

NAICS

811210 - Electronic and Precision Equipment Repair and Maintenance

Place of Performance

Harry S. Truman Memorial Veterans Hospital 800 Hospital Dr., Columbia, KS, 65201, USA

Set-Aside

NONE

Award Issued Date

Documents

3
DOCX, High priority: read this first1 page · amendment
High
DOCX, High priority: read this first1 page · amendment
High
DOCX, High priority: read this first32 pages · rfq
High

AI Contract Breakdown

Uniform Contract Format

Sign up to view the full breakdown with detailed analysis of each section.

Timeline

3 updates
PhaseAwarded
Posted

Combined Synopsis

Notice updated

The notice title changed. The notice description changed.

Notice updated

Notice details unchanged. Attachments may have changed.

Notice updated

Notice details unchanged. Attachments may have changed.

Awarded

Contract was awarded

Submission Closed

Find active opportunities like this

Get full access to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyDepartment Of Veterans Affairs → 255-NETWORK Contract Office 15 (36C255)
Contacts1 person available
OfficeLEAVENWORTH, KS, 66048, USA
Office AddressLEAVENWORTH, KS, 66048, USA
Contacts
George JohnsonContract Specialist

Full Description

Show more

THIS REQUEST FOR INFORMATION (RFI)/SOURCES SOUGHT DISCLAIMER 1. This RFI is issued solely for information and planning purposes only and does not constitute a solicitation. All information received in response to this RFI that is marked as proprietary will be handled accordingly. Responses to this notice are not offers and cannot be accepted by the Government to form a binding contract. Responders are solely responsible for all expenses associated with responding to this RFI. 2. The submission of pricing, capabilities for planning purposes, and other market information is highly encouraged and allowed under this RFI In Accordance With (IAW) FAR Part 15.201(e). SCOPE: Procurement of service agreement to maintain full-service support of Automatic Transfer Switches (ATS). This contract shall cover scheduled (preventive maintenance) and unscheduled (emergent) maintenance. All parts, labor, and travel shall be included. BACKGROUND: This contract will be used to provide full maintenance and testing service for the Harry S. Truman Memorial Veterans Hospital (HSTMVH). Proper maintenance of the ATS is needed to ensure the continued operation and transfer in case of a power outage. SITE VISIT: A site visit will be scheduled providing all potential bidders the opportunity to view the electrical distribution system. The date and time will be listed in the solicitation. BADGES, PARKING, CHECK-IN PROCESS: All Contractor personnel are required to wear identification (I.D.) badges issued by the HSTMVH Engineering office during the entire time they are on the HSTMVH grounds. It is the responsibility of the Contractor s personnel to park in the appropriate designated parking areas. The HSTMVH shall not validate or make reimbursement for parking violations of the Contractor s personnel under any circumstance. The contractor s technician shall report to the VA representative office Facilities Management prior to starting work. The Contractor s technician shall prepare a written service ticket explaining the work for the day, a listing of which parts are to be used, the price of each part and the total price of multiple parts. The ticket shall be given to the VA representative for approval. PERIOD OF PERFORMANCE: Base Year: 09/28/26-09/27/27,  OY 1- 09/28/27-09/27/28, OY2 09/28/28-09/27/29, OY3 09/28/29-09/27/30, OY4 09/28/31-09/27/31 : Fully qualified is based upon training and hands-on experience in the field.  For training, the Field Service Engineer (FSE) has successfully completed a formalized training program for the equipment identified in this solicitation as required by the Original Equipment Manufacturer (OEM) and equal to what the manufacturer provides their own field service personnel.  All PMs shall be provided by a manufacturer certified technician. Contractor must provide evidence of appropriate training of any FSE(s) providing services under terms of the contract.  Subcontracting of any ensuing award of this solicitation will not be allowed without written permission of the Contracting Officer. Contractor must have access to all OEM proprietary information due to the critical nature of these services.  Examples of this information would be software updates and factory service bulletins that describe updates/modifications needed to make the equipment under this contract safe for use. PERSONNEL ACCEPTANCE: The Government reserves the right to accept or reject Contractor s staff for the rendering of services. Complaints concerning Contract Personnel s performance or conduct shall be dealt with by the Contractor, VA representative and the final decision made by the Contracting Officer. CONTRACTOR S RESPONSIBILITIES: The Contractor shall take all precautions necessary to protect against injury or damage during the performance of this contract. The Contractor shall be responsible for any injury to contractor s employees as well as for any damage to personal or public property that occurs during the performance of this contract that is caused by contractor s employees fault or negligence. Enforce contractor performance (timely submission of deliverables, compliance with personnel screening requirements, and appropriate termination activity as appropriate). The authorization requirements do not apply, a Security Accreditation Package is not required. HOURS OF SERVICES: The Contractor shall perform the services as specified herein Monday through Friday except for National Holidays between the hours of 6:00p.m. 6:00a.m. Government national holidays: The Contractor is not required to provide services on the following national holidays nor shall the Contractor be paid for these holidays: New Year s Day January 1 Martin Luther King s Birthday Third Monday in January President s Day Third Monday in February Memorial Day Last Monday in May Juneteenth June 19 Independence Day July 4 Labor Day First Monday in September Columbus Day Second Monday in October Veterans Day November 11 Thanksgiving Day Fourth Thursday in November Christmas Day December 25 When a holiday falls on a Sunday, the following Monday will be observed as a legal holiday. When a holiday falls on a Saturday, the preceding Friday is observed as a legal holiday by the U.S. Government agencies. Also included, would be any other day specifically declared by the President of the United States of America to be a National Holiday. AUTOMATIC TRANSFER SWITCHES: The following ATS shall be covered under this contract: TABLE 1: HSTMVH ATS LISTING Location Local Identifier Make ATS Model Amperage EE# E009 ATS-1 ASCO Transfer Switch, Series 7000, 480V 400 112962 E003A ATS-2 ASCO Transfer Switch, Series 7000, 480V 800 112963 E009 ATS-3 ASCO Transfer Switch, Series 7000, 480V 600 112964 E009 ATS-4 ASCO Transfer Switch, Series 7000, 480V 400 112965 D022 ATS-EL ASCO Transfer Switch, Series 7000, 480V 600 38169 D022 ATS-LS ASCO Transfer Switch, Series 7000, 480V 600 77309 D022 ATS-EQ1 ASCO Transfer Switch, Series 7000, 480V 800 77312 D022 ATS-EQ2 ASCO Transfer Switch, Series 7000, 480V 1600 136955 D022 ATS-EQ3 ASCO Transfer Switch, Series 7000, 480V 800 TBD D022 ATS-C1 ASCO Transfer Switch, Series 7000, 480V 600 77310 D022 ATS-C2 ASCO Transfer Switch, Series 7000, 480V 800 77311 D022 ATS-C3 ASCO Transfer Switch, Series 7000, 480V 600 136954 D020 ATS-C4 Zenith Transfer Switch, ZBTS00B10160E, 480V 1600 136952 D017 ATS-FP Metron Transfer Switch, MP 300-50-480C, 480V 100 77315 SCHEDULE OF WORK: The vendor shall provide work at the intervals defined below. The contract is a base plus four option years. ATS Maintenance (See Note Below Table) ATS-1, ASCO Transfer Switch, Series 7000, 480V, 400A Every 12 months ATS-2, ASCO Transfer Switch, Series 7000, 480V, 800A Every 12 months ATS-3, ASCO Transfer Switch, Series 7000, 480V, 600A Every 12 months ATS-4, ASCO Transfer Switch, Series 7000, 480V, 400A Every 12 months ATS-EL, ASCO Transfer Switch, Series 7000, 480V, 600A Every 12 months ATS-LS, ASCO Transfer Switch, Series 7000, 480V, 600A Every 12 months ATS-EQ1, ASCO Transfer Switch, Series 7000, 480V, 800A Every 12 months ATS-EQ2, ASCO Transfer Switch, Series 7000, 480V, 1600A Every 12 months ATS-EQ3, ASCO Transfer Switch, Series 7000, 480V, 800A Every 12 months ATS-C1, ASCO Transfer Switch, Series 7000, 480V, 600A Every 12 months ATS-C2, ASCO Transfer Switch, Series 7000, 480V, 800A Every 12 months ATS-C3, ASCO Transfer Switch, Series 7000, 480V, 600A Every 12 months ATS-C4, Zenith Transfer Switch, ZBTS00B10160E, 480V, 1600A Every 12 months ATS-FP, Metron Transfer Switch, MP 300-50-480C, 480V, 100A Every 12 months MAINTENANCE: Preventive maintenance procedures shall be in accordance with the most current code; NFPA 110: Standard for Emergency and Standby Power Systems. The vendor shall perform preventive maintenance (PM) per ATS manufacturer s specifications. shall provide all PM kits and parts necessary to complete the PM per the manufacturer s specifications. General Work Items Check all lighted signals and replace bulbs as necessary. Inspect enclosure, wiring, and connections for any signs of damage, wear, or excessive heat. Clean enclosure and components to remove dust, dirt, and debris. Check switch contacts; remove transfer switch barriers and check the condition of the contacts; replace contacts if pitted, excessively worn or indicate high resistance readings; carefully reinstall barriers. VA will pay material cost for replacement of contacts. Inspect all components, including contacts, relays, switches, and control panels for signs of wear, corrosion, or overheating. Check transfer switch lubrication; if necessary by visual inspection, renew all factory lubrication on all movements and linkages; relubricate solenoid operator if transfer switch coil is replaced. Do not use oil, use Factory approved lubricant as recommended by each switch manufacturer. Check all cable connections and retighten them as necessary. Verify and adjust sensitivity settings and time delays as per manufacturer s specifications. Perform all necessary tests on transfer switch to assure proper operation; return switch to a ready state for transfer of loads to emergency power in the event of a normal power outage. Each switch shall be operationally tested at the conclusion of the individual switch maintenance procedures. Parts for Repair For repairs, Contractor shall furnish the COR with an estimate (via email) of the cost to make necessary repairs. Contractor shall also provide a comparison quote to the COR for what that item would have cost for commercial pricing so Government has basis for making price fair and reasonableness determination, or as alternative, Contractor shall provide a quote provided to another federal agency for similar item for determination purposes. All required parts shall be provided by the Contractor. No equipment or parts shall be considered obsolete until they are out of production for 7 years or cannot be replaced with a similar device or piece of equipment. After repairs to the ATS equipment have been completed, the VA representative must indicate acceptance of the work by stating acceptance on the repair ticket and by signing the ticket. A copy of the properly approved ticket shall accompany the payment invoice, and without proper signatures, the service call shall not be paid. REPORTING REQUIREMENTS: Contractor shall provide report for each ATS with all data points included. Service reports shall be delivered electronically within 7 calendar days after completing any work. Contractor shall provide handwritten notes before leaving station. Records of lockout tagout shall be maintained by service technician and listed in service report. Contractor is to prepare an annual report as to the improvements, maintenance, and service and over-all condition of the ATS equipment. Report shall include: all equipment describing repairs and/or corrections completed and suggestions for future work. 3. This is NOT a solicitation announcement. This is an RFI/sources sought only. The purpose of this sources sought/RFI is to gain knowledge of potential qualified sources and their size classification relative to NAICS 56120 . Responses to this sources sought will be used by the Government to make appropriate acquisition decisions. After review of the responses to this sources sought, a solicitation announcement may be published. Responses to this sources sought synopsis are not considered adequate responses for a solicitation announcement. 4. The Department of Veterans Affairs (VA), VISN 15 Network Contracting Office, is seeking sources that can provide the following: This contract is issued to ensure the continuous reliability of the boiler system identified in the statement of work. Malfunctioning burners or controls can cause catastrophic events resulting in injuries and death and massive property damage. Inaccurate or inadequate data management and monitoring systems can fail to warn of unsafe or inefficient performance. Regular inspections, testing and calibration are an essential part of a program to address these concerns. 5. It is the responsibility of the interested source to demonstrate to the government that the interested parties can provide the supplies/services that fulfill the requirement. If you are interested, and are capable of providing the sought out services, please provide the requested information as well as the information indicated below . Failure to respond to all questions in this sources sought will determine the interested party as non-responsive which may affect a set-aside decision for a resulting solicitation. Response to this notice should include company name, address, point of contact, size of business pursuant to the following questions: a. Please provide your UEI number. b. Please indicate the size status and representations of your business, such as but not limited to: Service Disabled Veteran Owned Small Business (SDVOSB), Veteran Owned Small Business (VOSB), Hubzone, Woman Owned Small Business (WOSB), Large Business, etc.)? c. Is your company considered small under the NAICS code identified under this RFI? d. Are you the manufacturer, distributor, or an equivalent solution to the items being referenced above? e. If you re an SDVOSB, VOSB or small business and you are an authorized distributor/reseller for the items identified above or an equivalent solution, do you alter; assemble; modify; the items requested in any way? If you do, state how and what is altered; assembled; modified? f. If you are identified as a SDVOSB/VOSB or SB, Identify how you intend to meet the requirements found in the limitations on subcontracting FAR or VAAR clauses. (providing 51% of the work outlined in section 4 above) g. Does your company have an FSS contract with GSA, VA NAC, NASA SEWP, or any other federal contract, that can be utilized to procure the requirement listed above? If so, please provide the contract number(s). h. Please submit your capabilities that show clear, compelling, and convincing evidence that you can meet the requirement described above. 6. Responses to this notice shall be submitted via email to contact@example.gov. Telephone responses shall not be accepted. Responses must be received no later than Thursday 09/25/26 at 10:00 am CST. If a solicitation is issued it shall be announced at a later date, and all interested parties must respond to that solicitation announcement separately from the responses to this sources sought. Responses to this sources sought notice are not a request to be added to a prospective bidders list or to receive a copy of the solicitation.

More opportunities from Department Of Veterans Affairs → 255-NETWORK Contract Office 15 (36C255)

Same awarding agency

NAICS: 238210
New
Federal
657A5-26-111, Triennial Electrical Testing
Solicitation # 36C25526R0186
Solicitation 36C25526R0186 is a fixed-price construction request for proposal issued by the Department of Veterans Affairs Network Contracting Office 15 for triennial electrical testing at the Marion VA Medical Center in Marion, Illinois. This project is a total set-aside for Service-Disabled Veteran Owned Small Businesses (SDVOSB) with an estimated magnitude between $500,000 and $1,000,000. The scope of work involves the maintenance, inspection, adjustment, testing, and calibration of the facility's Electrical Power Distribution System, specifically covering approximately 325 electrical panels, 135 medium and low voltage transformers, 220 switches, 6 generators, and 25 automatic transfer switches. All work must adhere to NETA 2019 standards, VHA Directive 1028, NFPA 99, NFPA 110, NFPA 70B, and the latest National Electrical Code. The contract will be awarded using the Lowest Price Technically Acceptable (LPTA) process, evaluating offerors on five technical factors: relevant past performance of the prime contractor, technical experience of the prime and electrical subcontractor, qualifications of key personnel, and the prime contractor's safety plan. To be acceptable, the prime contractor must demonstrate completion of two to three similar hospital electrical projects valued at $500,000 or more within the last five years. The period of performance is 150 calendar days, and the contractor is required to provide a four-week notice for any power outages. Key administrative requirements include the submission of bid, performance, and payment bonds, compliance with the Davis-Bacon Act and Buy American requirements, and the delivery of detailed maintenance and testing reports.
Electrical Contractors and Other Wiring Installation Contractors

POSTED

2 days ago

DEADLINE

in 5 days
View Details
NAICS: 236220
New
Federal
Z2DA--657-27-111JB, Install Continuous Water Monitoring System, JB- STL
Solicitation # 36C25527Q0052
The Department of Veterans Affairs, Network Contracting Office 15, has issued a Sources Sought Notice for project 657-27-111JB to install a continuous water monitoring system at the Jefferson Barracks VAMC in St. Louis, Missouri. This market research effort aims to identify qualified Service-Disabled Veteran-Owned Small Business (SDVOSB) firms under NAICS code 236220, General Construction, to determine if a set-aside is appropriate before issuing a Best Value type Request for Proposal. The project scope involves installing monitoring equipment for biocides, pH levels, pressure, and temperature at domestic cold water sources and hot water generation across Buildings 3, 51, 52, 53, and 59. Requirements include installing sensors at incoming cold water sources, distal points, and hot water source equipment, as well as monitoring temperatures at riser midpoints. All systems must be back net capable for real-time monitoring and integration with the VA Johnson controls Building Automation System, and all work must comply with VHA Directive 1061. The selected contractor will also be required to provide comprehensive training on the new monitoring equipment and basic instrumentation and control training. Interested firms must submit a capability statement of no more than ten single-sided pages by November 12, 2026, at 10:00 am Central Time to Contracting Officer Jennifer Hill. The submission must include company identification, EIN, CVE certification, socio-economic status, a percentage of self-performed labor, joint venture information, and a surety letter detailing bonding capabilities. Additionally, firms must provide at least three examples of comparable work performed within the last five years, including project descriptions, customer satisfaction, and dollar values.
Commercial and Institutional Building Construction

POSTED

3 days ago

DEADLINE

in 4 days
View Details

Find Active Opportunities Like This

Get AI-powered intelligence on the opportunities still open

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS