Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, October 28 at 2:00 PM ET

Register Free →

This Sources Sought opportunity from Department Of Veterans Affairs was posted on May 4, 2026. The submission period has ended. Browse the details below for market research, or find similar active opportunities.

H335--Underground Storage Tanks Testing and Inspection Services at Edward Hines, Jr. VA Hospital in Hines, IL

Closed
36C25226Q0450Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

Active Opportunities Like This One

NAICS: 541620
New
SLED
Debris Monitoring Services
Solicitation # 2026-281
Collin County, Texas, is soliciting proposals for a stand-by contract for debris monitoring services to provide disaster recovery technical program management assistance on an as-needed basis. The primary objective is to ensure that all debris removal operations from public rights-of-way, private property, and other designated areas are documented in strict compliance with FEMA Public Assistance Program guidelines, 2 CFR 200, and other federal or state relief program regulations to maximize cost recovery. The contract features an initial one-year term with five optional one-year renewals. The scope of work includes real-time processing of load tickets via an automated tracking system, submission of daily operational and safety reports, and the validation of contractor invoices. All project documentation must be retained for at least seven years. The contract will be awarded to the responsible contractor offering the best evaluated offer through a multi-phase process involving a compliance review, a detailed proposal assessment, and optional demonstrations. Pricing is based on hourly rates for various specialized positions, such as project inspectors and grant management consultants. Per updated terms, all rates must be all-inclusive of insurance, taxes, overhead, and profit, with no separate payments for mobilization or demobilization. Additional charges must be structured as direct reimbursable expenses adhering to federal FEMA policies. Successful proposers may be required to provide performance and payment bonds for 100 percent of the contract total and must certify compliance with the Buy America Act, Davis-Bacon Act, and various federal labor and safety standards.
Fire Marshal

POSTED

about 11 hours ago

DEADLINE

in 1 day
NAICS: 541620
New
Federal
F108--657A4-21-800 - VPIH Services for Remove and Replace End of Life Heating, Ventilation and Air Conditioning Construction
Solicitation # 36C25527R0004
The Department of Veterans Affairs, Network Contracting Office 15, is seeking qualifications from Service-Disabled Veteran Owned Small Business (SDVOSB) firms to provide Veterans Professional Industrial Hygiene (VPIH) oversight services. This requirement supports construction project 657A4-21-800, which involves the removal and replacement of end-of-life heating, ventilation, and air conditioning (HVAC) systems in Building 1 at the John J. Pershing VA Medical Center in Poplar Bluff, Missouri. The anticipated contract will be a Firm Fixed Price award, with the associated construction project projected to conclude by December 27, 2028. VPIH oversight services are divided into four phases totaling 46 days of work, requiring close coordination with the Contracting Officer's Representative and the abatement contractor. This procurement is conducted in accordance with the Brooks Act and FAR Subpart 36, meaning firms will be selected based on competence and qualifications rather than price. Interested firms must submit a completed Standard Form 330 by November 2, 2026, at 2:00 PM CST. Evaluation criteria, listed in descending order of importance, include professional qualifications of key personnel, specialized experience in healthcare or active medical center environments, capacity to accomplish the work, past performance, and a record of claims or litigation. To be eligible, firms must be verified in the SBA registry, registered in the System for Award Management, and certify compliance with VAAR 852.219-75, ensuring that no more than 50 percent of the contract value is paid to non-SDVOSB firms.
255-NETWORK Contract Office 15 (36C255)

POSTED

about 15 hours ago

DEADLINE

in 6 days
NAICS: 541620
New
SLED
ENVIRONMENTAL TRUST Comprehensive E mergency Management Plan Update & Environmental Engineering and Consulting Services
Solicitation # Environmental-Trust_RFP_FY-2027_Emergency-Plan-Update-Environmental-Services_10202026.pdf
The Confederated Tribes of the Colville Reservation is seeking professional services for a combined maximum budget of $289,497, divided into two primary functional areas. The first area, Emergency Management Planning, is capped at $150,000 and involves updating the 2014 Comprehensive Emergency Management Plan, developing Emergency Support Functions, creating hazard-specific annexes, and establishing the Tribes' first Continuity of Operations Plan and Tribal Threat and Hazard Identification and Risk Assessment. This scope also includes the development of an all-hazards tabletop exercise package and the facilitation of coordination workshops to integrate these planning components. The second area, Environmental Engineering and Consulting Services, is capped at $139,497 and focuses on technical field operations in Nespelem, Washington. Key tasks include biannual groundwater monitoring and testing at the Nespelem Post and Pole site, as well as the characterization, removal, and lawful disposal of hazardous materials at the Nespelem Recycle Center. The contractor must adhere to strict quality standards, including the use of approved Quality Assurance Project Plans and Health and Safety Plans, and provide detailed verification reports. Mandatory monthly progress reports are required for all activities, and all project communication costs must be integrated into the respective task budgets. TERO fees are handled separately by the Tribal Employment Rights Office and are not included in the scope of work budget.
Confederated Tribes of the Colville Reservation

POSTED

1 day ago

DEADLINE

in 9 days

AI Contract Overview

Show more

This notice seeks information from qualified sources capable of performing inspection, maintenance, testing, and repair services for nineteen fuel storage tanks—sixteen underground and three aboveground—at the Edward Hines Jr. VA Hospital in Hines, Illinois. The work must comply with federal regulations under 40 CFR Part 280, the Energy Policy Act of 2005, VHA Directive GEMS 7700, and Illinois State Fire Marshal (OSFM/ISFM) requirements, including adherence to Illinois Administrative Code Title 35, Part 731 for air quality. All services must be conducted by directly employed, certified Level A and B UST/AST inspectors and Illinois-certified tank installers holding valid Class A, B, and C UST operator certifications. Monthly inspections are scheduled for the third or fourth week of each month, while annual and triennial inspections occur in October. Work is restricted to weekdays, 7:00 a.m. to 3:30 p.m., excluding federal holidays, and contractors must request site access at least one week in advance. The contractor is responsible for reviewing historical records including SPCC plans, tank registrations, and permitting documentation, conducting comprehensive on-site inspections with written and photographic documentation, and delivering formal reports using OSFM standards that include pass/fail determinations, equipment identification, service logs, operator training records, and recommendations for corrective actions. All reports must be submitted to VA Engineering and transmitted to OSFM to ensure regulatory compliance, and any identified deficiencies must be communicated to the Contracting Officer’s Representative for resolution. The contractor must maintain an adequate inventory of parts and materials and shall not subcontract any portion of the work; all tasks must be self-performed by the contractor’s direct employees. Only firms with at least five consecutive years of proven experience in UST/AST servicing and compliance with Illinois and federal environmental agencies are eligible, and bidders must provide three client references, preferably from government entities. The submission must include proof of certifications, SAM UEI and DUNS numbers, business size status, quality control procedures, and must be no more than twenty-five pages in Word or PDF format, submitted by the May 7, 2026 deadline. This is a sources sought notice, not a solicitation for bids, and is intended solely to gather market information to determine future acquisition strategy.

General Info

VA seeks certified contractors for monthly/annual fuel tank inspections and repairs at Hines IL hospital, no subcontracting, strict regulatory compliance required.

NAICS

541620 - Environmental Consulting Services

Place of Performance

Edward Hines, Jr. VA Hospital, Hines, IL, 60141-5000, USA

Set-Aside

NONE

Documents

1

Sources Sought 36C25226Q0450 Underground Storage Tanks Testing and Inspection Services

DOCX, Low prioritysources-sought
Low

AI Contract Breakdown

Uniform Contract Format

Sign up to view the full breakdown with detailed analysis of each section.

Timeline

PhaseClosed
Posted

Sources Sought

Response Deadline

Deadline has passed

Submission Closed

Find active opportunities like this

Start your free trial to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyDepartment Of Veterans Affairs → 252-NETWORK Contract Office 12 (36C252)
Contacts1 person available
OfficeMILWAUKEE, WI, 53214, USA
Office AddressMILWAUKEE, WI, 53214, USA
Contacts
Lemke JustinContract Specialist

Full Description

Show more
This is not a solicitation for proposals, proposal abstracts, bids, or quotations. The purpose of this notice is to obtain information regarding the availability and capability of all qualified sources to perform Siemens Uroskop De-Installation Services at Captain James A. Lovell Federal Health Care Center. Responses to the information requested will assist the Government in determining the appropriate acquisition method. It is understood that all firms submitting a response to this Sources Sought will have an established business in the industry of Underground Tank Testing and Inspection Services in accordance with requirements listed below.
DESCRIPTION OF SERVICES
Edward J. Hines Jr. VA hospital requires the services of a contractor for inspection, maintenance, testing, and repair services for nineteen (19) diesel/unleaded storage tanks located throughout the Hines VA Campus per 40 CFR Part 280. (16) Underground Storage Tanks (UST) (03) Above Ground Storage Tanks (AST)
Overview of requirements The bidding contractors shall be certified by Office of the Illinois State Fire Marshall-(OSFM) & Illinois Class ABC certification Review historical records of tank performance Maintain Hines Storage Tank Records Coordinate Storage Tank compliance and permitting efforts with OSFM Work with engineering staff to evaluate maintenance and repair options Inspect tank system for compliance with federal, state, and local environmental regulations Provide formalized report on inspection and recommendations for each tank system Transmit inspection records to OFSM to ensure Hines is compliant Provide certification process guidance and ensure permits are current and displayed Perform limited preventative maintenance repair that can be only accomplished by certified contractor
This contractor shall adhere to all regulatory program inspection requirements. These requirements shall include the Energy Policy Act of 2005, 40 CFR 280 under RCRA, VHA Directive GEMS 7700 and Illinois State Fire Marshall (ISFM). In addition, the inspections include adherence to air quality programs as identified by the Illinois Administrative Code Title 35, Part 731.


SCOPE
Contractor shall contact Hines VA Engineering, Contracting Officer Representative (COR) to request onsite inspections at least, one (1) week prior to the visit. The contractor is required to perform inspections and maintenance during normal work hours 7:00am 3:30pm Monday through Friday. Inspections will not occur on weekends or government holidays.
Contractor shall review records to include Spill Prevention, Control, and Countermeasure (SPCC) plans, tank registrations and compliance reports, agency inspections, tank vendor operating manuals, layout drawings, and permits. Contractor shall review the tank information available through Office of the Illinois State Fire Marshal agency databases and shall review state and local UST/AST code requirements with respect to the referenced tanks at the VA.
Inspection-On site Contractor shall conduct on-site inspection of all tanks in Attachment 2, with VA personnel to verify the current state and conditions of the UST/AST systems. The site inspection shall be conducted by a certified Level A and B UST/AST Tank System Inspector and Illinois certified tank installer. The inspection shall require both written and photo documentation if emergency or damage is discovered. The inspection shall include demonstration of the operation using real time monitoring systems used by VA personnel. This inspection shall include spill and overfill protection, corrosion protection, leak detection, secondary containment, spill preparedness kits for response, reporting of releases, and applicable compliance requirements.
Inspection-On site Time Frame and Delivery Monthly Inspection: 3rd or 4th week of month Annual Inspection: Month of October-No time constraints Triennial Inspection: Month of October-No time constraints

AST Inspection Note No monthly inspections needed on AST Only Fuel is tested once a year : Month of October-No time constraints
Inspection Close out At the completion of the on-site inspection, the contractor shall conduct an Inspection review meeting with VA representatives to present findings.
Meeting Agenda shall include identification of regulatory deficiencies discovered that could result in significant action by US EPA, IEPA, OISFM, state, local agencies or risk to patient health. The contractor shall review Hines VA tank program documentation/records of Inspected elements such as: tank registration forms, financial responsibility, submittals, tank testing, and tank inspections. Contractor to provide formalized report using OSFM Standards
REPORTING REQUIREMENTS
GEMS Documentation/Reports-Defined The Contractor shall be responsible to provide VA Engineering Service with a typed formal report of services performed. This formal Vendor Engineering Service Report shall include results, details and data for all services performed.
Contractor shall provide a report presenting inspection findings and fix recommendations for each tank system.
Items to be included & reported during inspections:
Tank Conditions Notification (failure to notify) Corrosion protection Tank Corrosion protection Piping Condition on retractors, hoses, breakaways, vapor caps, rubber gaskets, and swivels (dispensing islands only) Condition of all gauges and meters
Overfill/Spill Overfill prevention is in place and operational Spill prevention is in place and operational Tank and piping release detection Inspect piping/fitting conditions for failures, potential failures Detection methods and appropriate equipment or procedures are in place: alarms, interstitial piping, sump sensors Inspection, removal and disposal of debris in spill buckets. Secondary containment is present where required
Required Documentation
Prior to approval of invoices, contractor shall provide documents of:
Tank and piping repairs performed by contractor Any notice of Temporary tank closure or Permanent tank decommissioning and removal Documentation on inspecting Operator training Class A, B, and C Time stamps of equipment downtime/uptime and hours on-site for service call Identification of equipment to be serviced Inventory ID number, manufacturer's name, device name, model number, serial number, and any other manufacturer's identification numbers Itemized description of service(s) performed Name of Veteran Administration employee who witnessed service described Name of Field Service Engineer (FSE) who performed services Contractor service number or contractor log number Pass or Fail per tank inspected OSFM Quarterly Equipment Inspection Checklist/Operations & Maintenance Guidelines for UST System Inspections per tank
GENERAL REQUIREMENTS
Contractor to furnish all labor, materials, and transportation necessary to include:
All work under the provisions of this contract shall be performed by properly licensed and certified UST technicians directly employed by the contractor. UST Technicians shall be fully trained and experienced in the servicing of the systems and devices specified. Subject to COR approval. In addition to the conformance section of the specifications all work under the provisions of this contract shall be performed and certified as being in full compliance with all applicable laws, regulations and codes. At all times while performing work under the provisions of this contract the contractor s employees shall strictly observe the requirements of all applicable Occupational Safety and Health Administration, Environmental Protection Agency, Department of Veterans Affairs rules and the Illinois State Fire Marshal, regulations and policies. Existing UST alarms, piping and system components or devices found to be in a state of failure shall be reported to the COR for appropriate corrective action. Contractor shall troubleshoot and diagnosis as necessary to determine the cause of the problem identified. Contractor shall provide a cost proposal to make corrections or repairs to identify deficiencies for consideration by facility personnel.

CONTRACTOR QUALIFICATIONS
The contractor shall maintain an adequate inventory of parts, materials and supplies as necessary to provide for the timely maintenance, testing and repair of the specified UST/AST systems components and devices. Failure by the contractor to satisfactorily accomplish required inspections by the provisions of this contract in a timely manner because of a lack of parts/equipment availability shall be considered justification to terminate the contract in accordance with the Default Clause. Firms shall have been engaged in business of installing, repairing, testing, maintaining UST systems, and components verifying compliance with the Illinois State Fire Marshall and other regulatory offices for at least the past five (5) consecutive years. Bidders shall provide list of the names, addresses and telephone numbers of three (3) customer references with preference towards experience with the Federal or Illinois State governments. Contractors shall provide proof of Illinois Class A,B, and C UST certification in bid. Due to the dangers with Above and Underground Storage Tanks, there shall be no subcontracting opportunities for potential general contractors. Communications shall be from government to the self-performing contractor and vice versa only.

More opportunities from Department Of Veterans Affairs → 252-NETWORK Contract Office 12 (36C252)

Same awarding agency

NAICS: 238220
New
Federal
J041--Condenser Coils Replacement for the VA Illiana Health Care System (VAIHCS), located at 1900 E. Main Street, Danville, IL 61832.
Solicitation # 36C25227Q0051
Solicitation 36C25227Q0051 is a firm-fixed-price request for quote issued by the Department of Veterans Affairs for the OEM-approved replacement of condenser coils for CGAM060F2A chiller Circuits 1 and 2 at the VA Illiana Health Care System in Danville, Illinois. This procurement is set aside for Service-Disabled Veteran-Owned Small Businesses under NAICS code 238220. The scope of work includes recovering refrigerant per EPA Section 608, removing existing coils, installing new OEM-compliant coils, and performing comprehensive pressure and leak testing. The contractor must provide a final commissioning report and adhere to a strict performance period of thirty calendar days following the Notice to Proceed, with initial submittals and safety plans due within five business days of award. Award will be based on a comparative evaluation of price and other factors, including demonstrated experience with similar HVAC/chiller coil replacements, familiarity with Trane CGAM-series equipment, and required certifications such as EPA Section 608 and OSHA 10/30. The contractor is required to provide a competent superintendent per FAR 52.236-6 and comply with Department of Labor Wage Determination No. 2015-5021 for Vermilion County, Illinois. Key administrative requirements include a 50 percent limitation on payments to non-SDVOSB or non-VOSB firms and strict adherence to Controlled Unclassified Information (CUI) protocols. Quotes are due by November 4, 2026.
Plumbing, Heating, and Air-Conditioning Contractors

POSTED

about 15 hours ago

DEADLINE

in 8 days
View Details

Find Active Opportunities Like This

Get AI-powered intelligence on the opportunities still open

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS