Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, November 11 at 2:00 PM ET

Register Free →

This Sources Sought opportunity from Department Of Veterans Affairs was posted on July 7, 2026. The submission period has ended. Browse the details below for market research, or find similar active opportunities.

H942--36C25526Q0494 Lightning Protection, Inspection and Minor Repairs KC VA MEDICAL CENTER KANSAS CITY, MO

Awarded
36C25526Q0494Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

Active Opportunities Like This One

NAICS: 238210
New
26-140 Installation of Emergency Shut Off Switches
Solicitation # 26-140
Solicitation 26-140 is a subcontracting opportunity with Atterbury Job Corps Center, operated by Adams and Associates, Inc. for the U.S. Department of Labor, to install emergency shut-off switches in the Facility Engineering Storage/Maintenance Shop in Edinburgh, Indiana. The project requires the installation of two mushroom-head push-button emergency shut-off switches and a new 60A, 208/120V, 3-phase, 4-wire, 6-circuit branch circuit panel with a 60A shunt-trip main circuit breaker. All work must comply with OSHA, EPA, and national building codes, as well as FNC guidelines. Deliverables include the hardware installation, required training, operating and maintenance manuals, and manufacturer warranties. The procurement is set aside for small businesses, including VOSB, SDVOSB, WOSB, and HUBZone certifications. Interested offerors must attend a mandatory site visit on November 10, 2026, and submit a typed proposal on company letterhead by November 20, 2026. Bids must be submitted as a single lump sum with a detailed cost breakdown for labor, materials, and equipment. Award will be based on best value, evaluated by price (60 points), quality (20 points), past performance (10 points), and schedule (10 points). Contractors must hold a valid State of Indiana Contractor's License and provide proof of General Liability, Automobile Liability, and Workers Compensation insurance. Compliance with the Davis Bacon Act wage rates is required. The contract features Net 30 payment terms and a one-year guarantee of workmanship from the date of substantial completion. Final payment is contingent upon the submission of a completed SF 1413 and the release of liens by all subcontractors and suppliers.
Atterbury Job Corps. – Adams & Associates

POSTED

about 6 hours ago

DEADLINE

in 21 days
NAICS: 238210
New
Transformer Oil Testing Services
Solicitation # RFP-VC-26-010
The Inland Empire Utilities Agency is soliciting proposals under RFP-VC-26-010 for professional transformer oil testing services to enhance the reliability, safety, and maintainability of its transformers. The scope of work comprises three primary components: performing visual and infrared thermographic inspections on energized transformers under typical load, installing standardized external oil sampling devices to improve safety and access, and conducting comprehensive oil testing analysis. The selected contractor must adhere to NETA MTS, IEEE, and NFPA 70E safety protocols, as well as ASTM D923 for sampling. Key deliverables include annotated infrared images, written condition assessment reports for each asset, standard operating procedures, and on-site training for up to 20 agency staff members. Additionally, the contractor is responsible for evaluating nitrogen blanket systems and ensuring all pressure and oil level gauges are clearly marked with appropriate operating ranges. This is a small business set-aside solicitation with a proposal submission deadline of December 23, 2026, via PlanetBids. The agency intends to make a single award based on the offeror's past performance, personnel experience, staffing methodology, and cost-effectiveness. Qualified proposers must have completed at least two similar projects within the last five years, including at least one for a utility or industrial facility. Proposals must include a detailed company profile, project approach, and various required forms, including a non-collusion statement and a certificate of insurance. Payment will be processed electronically via ACH within 30 days of invoice approval, with early payment discounts available for invoice reductions of 1%, 2%, or 5%. All project data and reports are considered confidential and remain the property of the agency.
Inland Empire Utilities Agency

POSTED

about 6 hours ago

DEADLINE

in about 2 months
NAICS: 238210
New
Purified Water Replenishment San Jacinto Valley Advanced Water Purification Facility
Solicitation # purified-water-replenishment-san-jacinto-valley-advanced-water-purification-facility-2
Axia Electric LLC is soliciting bids from SBE/DBE certified firms for the Eastern Municipal Water District's Purified Water Replenishment San Jacinto Valley Advanced Water Purification Facility Project in California. The scope of work is divided between the San Jacinto Valley Advanced Water Purification Facility and the Brine Ponds, specifically requesting subcontractors for low voltage systems, fiber optics, and electrical materials and supplies. Bids must be submitted by 2:00 PM on November 18th, with a final deadline of November 19th, 2026. Quotes should be emailed to Ryan Falk, the lead estimator. Qualified bidders must be registered to perform public work pursuant to Labor Code Section 1725.5 and agree to abide by the AGC Master Labor Agreements, the prime contract terms, and Axia's Standard Long Form Subcontract or Purchase Order. Minimum insurance requirements include 5 million dollars in excess liability, 1 million dollars for auto liability, 1 million dollars for workers compensation and employer liability, and general liability coverage of 1 million dollars per occurrence, 2 million dollars aggregate, and 2 million dollars for completed operations. Evaluation will be based on responsiveness to deadlines, insurance compliance, and SBE/DBE participation, including any lower-tier participation provided by non-certified firms.
Axia Electric

POSTED

about 6 hours ago

DEADLINE

in 20 days
NAICS: 238210
New
Centennial JCC Emergency Lighting Replacement, Upgrade, Testing & Maintenance Services
Solicitation # centennial-jcc-emergency-lighting-replacement-upgrade-testing-maintenance-services
Management & Training Corporation is soliciting bids for a fixed-price, single lump sum contract to provide emergency lighting replacement, upgrade, testing, and maintenance services at the Centennial Job Corps Center in Nampa, Idaho. The project involves a qualified electrical contractor inspecting, testing, repairing, and certifying emergency lighting systems across the facility to ensure compliance with NFPA 101 (2024 Edition) and NFPA 70 standards. Key tasks include inventorying fixtures, performing functional power-outage simulations, applying durable tracking labels to fixtures, and integrating recurring maintenance into the operator's Computerized Maintenance Management System. The estimated contract value ranges between $25,000 and $100,000, with a required performance period of 30 business days following the Notice to Proceed. Bids are due by December 1, 2026, and will be awarded based on overall best value. Mandatory requirements for submission include a physical site visit, a signed bid form, and a detailed cost breakout. For bids of $25,000 or more, contractors must provide a bid bond equal to 20% of the base bid, as well as performance and payment bonds from a surety with at least an A- rating. The contract is subject to the Davis-Bacon Act, FAR work hour and safety standards, and specific small business set-aside classifications. Awarded contractors must provide certificates of disposal for hazardous materials and manufacturer warranties for all equipment and workmanship.
Management & Training Corporation/Centennial Job Corps Center

POSTED

about 6 hours ago

DEADLINE

in about 1 month

AI Contract Overview

Show more

The Department of Veterans Affairs, through the VISN 15 Network Contracting Office, is issuing a Request for Information (RFI) and Sources Sought notice to identify qualified small businesses capable of providing lightning protection system inspection, repair, and UL Master Label recertification services at the Kansas City VA Medical Center. This is not a solicitation for contract award but a market research tool aimed at gathering information on potential vendors, particularly those classified as Service-Disabled Veteran-Owned Small Businesses, to inform future acquisition decisions. Entities interested in responding must demonstrate their ability to meet the detailed technical requirements outlined in the Statement of Work, including full compliance with NFPA 70, NFPA 780, UL 96A, ANSI/CAN/UL 96:2016, and LPI 175 standards. The scope involves inspecting, documenting, and repairing lightning protection systems across ten primary buildings and the Honor Annex, correcting all deficiencies, performing system verification, and securing UL Master Label recertification for each structure. Respondents are required to provide company details, UEI number, size status, role as manufacturer or distributor, modifications to equipment, FSS contract information, and clear evidence of capability to execute the work. Submissions must be emailed to Lisa Fischer at [email hidden] no later than 3:00 PM CST on Friday, July 24, 2026, and must include all requested information, including high-resolution photographs of deficiencies and proposed solutions. Responses will not be treated as offers nor will they entitle the responder to future bid notifications or inclusion on any bidder list. A pre-bid site visit is strongly encouraged, and contractors must be prepared to operate under strict safety protocols per OSHA and VA policies while working in a live medical facility. All work must be performed in a workmanlike manner, with daily debris removal, proper fall protection, and detailed before-and-after documentation for each repair. While this RFI does not guarantee a solicitation, any resulting procurement will be issued as a Service-Disabled Veteran-Owned Small Business (SDVOSB) Set Aside under NAICS code 238210, and eligible respondents must clearly articulate their size certification and ability to deliver the technical requirements without additional cost to the government.

General Info

RFI seeks SDVOSB vendors for lightning protection inspections, repairs, and UL recertification at Kansas City VA Medical Center.

Contract Value

$24,576.4

NAICS

238210 - Electrical Contractors and Other Wiring Installation Contractors

Place of Performance

Kansas City VA Medical Center & Honor Annex, Kansas City, KS, 64128, USA

Set-Aside

SDVOSBC

Award Issued Date

Documents

1

RFI 36C25526Q0494 Lightning Protection Inspection and Repairs KC VA Medical Center

DOCX, High priority: read this firstsources-sought
High

AI Contract Breakdown

Uniform Contract Format

Sign up to view the full breakdown with detailed analysis of each section.

Timeline

PhaseAwarded
Posted

Sources Sought

Awarded

Contract was awarded

Submission Closed

Find active opportunities like this

Get full access to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyDepartment Of Veterans Affairs → 255-NETWORK Contract Office 15 (36C255)
Contacts1 person available
OfficeLEAVENWORTH, KS, 66048, USA
Office AddressLEAVENWORTH, KS, 66048, USA
Contacts
Lisa FischerContracting Specialist

Full Description

Show more
THIS REQUEST FOR INFORMATION (RFI)/SOURCES SOUGHT DISCLAIMER
This RFI is issued solely for information and planning purposes only and does not constitute a solicitation. All information received in response to this RFI that is marked as proprietary will be handled accordingly. Responses to this notice are not offers and cannot be accepted by the Government to form a binding contract. Responders are solely responsible for all expenses associated with responding to this RFI.
The submission of pricing, capabilities for planning purposes, and other market information is highly encouraged and allowed under this RFI In Accordance With (IAW) FAR Part 15.201(e).
SOURCES SOUGHT DESCRIPTION
This is NOT a solicitation announcement. This is a RFI/sources sought only. The purpose of this sources sought/RFI is to gain knowledge of potential qualified sources and their size classification relative to NAICS 238210. Responses to this sources sought will be used by the Government to make appropriate acquisition decisions. After reviewing the responses to this sources sought, a solicitation announcement may be published. Responses to this sources sought synopsis are not considered adequate responses for a solicitation announcement.
The Department of Veterans Affairs (VA), VISN 15 Network Contracting Office, is seeking sources that can provide the following:
LIGHTNING PROTECTION INSPECTION, REPAIRS AND CERTIFICATION It is the responsibility of the interested source to demonstrate to the government that the interested parties can provide the supplies/services that fulfill the brand name.
If you are interested and can provide sought-out supplies/services, please provide the requested information as well as the information indicated below.
Response to this notice should include company name, address, point of contact, size of business pursuant to the following questions:
Please indicate the size status and representations of your business, such as but not limited to: Service Disabled Veteran Owned Small Business (SDVOSB), Veteran Owned Small Business (VOSB), HUBZone, Woman Owned Small Business (WOSB), Large Business, etc.)
Is your company considered small under the NAICS code identified under this RFI?
Are you the manufacturer, distributor, or an equivalent solution to the items being referenced above?
If you re a small business and you are an authorized distributor/reseller for the items identified above or an equivalent solution, do you alter; assemble; modify; the items requested in any way? If you do, state how and what is altered; assembled; modified?
Does your company have an FSS contract with GSA, VA NAC, NASA SEWP, or any other federal contract, that can be utilized to procure the requirement listed above. If so, please provide the contract number.
Please submit your capabilities that show clear, compelling, and convincing evidence that you can meet the requirements described in the attached SOW.
Please provide your SAM s UEI number.
Responses to this notice shall be submitted via email to Lisa Fischer at contact@example.gov. Telephone responses shall not be accepted. Responses must be received no later than Friday July 24th, 2026, by 1500 PM CST. If a solicitation is issued it shall be announced at a later date, and all interested parties must respond to that solicitation announcement separately from the responses to this sources sought. Responses to this sources sought notice are not a request to be added to a prospective bidders list or to receive a copy of the solicitation
DEPARTMENT OF VETERANS AFFAIRS MEDICAL CENTER KANSAS CITY VA MEDICAL CENTER
STATEMENT OF REQUIREMENT
STATEMENT OF WORK (SOW)
Project Title: Lightning Protection System Inspection, Repair, and UL Master Label Recertification Location: Kansas City VA Medical Center, 4801 East Linwood Blvd, Kansas City, MO 64128 1. Project Overview The Contractor shall provide all labor, materials, tools, equipment, and supervision necessary to inspect, repair, and recertify the Lightning Protection Systems (LPS) for Buildings 1, 2, 3, 4, 5, 6, 15, 26, 40, and 56 at the Kansas City VA Medical Center along with the Honor Annex. Work includes system inspection, documentation of deficiencies with photographs, repair of all deficiencies, follow-up verification, and obtaining a UL Master Label for each system. The Contractor shall confirm compliance with NFPA 70, NFPA 780, LPI 175, UL 96A, and ANSI/CAN/UL 96:2016. 2. Background The Kansas City VA Medical Center operates lightning protection systems on multiple buildings as part of its life safety and infrastructure protection strategy. Various components have become damaged, aged, or require updating to meet current safety standards. Some installations exist in locations with limited maintenance access and may require specialized equipment. A complete inspection, repair effort, and recertification process is required to restore protection to the facility. 3. Scope of Work 3.1 Inspection Requirements The Contractor shall perform a complete inspection of all LPS components for each building prior to repairs. Inspections shall: Be organized by building, then by area. Document each deficiency in writing. Include clear, high-resolution photographs for each deficiency. Be submitted electronically to the COR.
3.2 Repair and Installation Requirements All work shall be installed in a neat and workmanlike manner. Deficient work shall be corrected at no additional cost to the Government. Required work includes but is not limited to: Remove and replace damaged air terminals. Remove and replace damaged main, secondary, and loop conductors. Remove and replace damaged grounding electrodes. Remove and replace damaged fasteners. Remove and replace components involving dissimilar metals. Install missing or required cabling, components, fasteners, and electrodes.
3.3 System Verification Requirements The Contractor shall verify proper: Air terminal spacing. Air terminal material class. Conductor material class. Conductor fastener spacing. Cable installation, including allowable bends, dual paths to ground, downward routing, and 3/12 rise requirements. Side-flash bonding installation. Bonding to handrails, piping, and mechanical/electrical equipment. Mechanical connection torque values. Grounding electrode quantity and placement. Grounding electrode connections.
3.4 Utility Bonding Verification Where visible, Contractor shall verify bonding at: Main gas point of entry (first 10 feet). Main water point of entry (first 5 feet). Main fire sprinkler point of entry (bridged with water main). Main electrical ground bus. Main telephone point of entry. If bonding is not visible, Contractor shall recommend corrective actions necessary to allow UL recertification. 3.5 Follow-Up Reporting Upon completion of repairs, the Contractor shall: Photograph each completed repair. Present before-and-after photographs side-by-side. Develop a follow-up report matching the structure of the initial inspection report.
3.6 Unforeseen Site Conditions The VA anticipates possible discovery of additional deficiencies during inspection. The Contractor shall: Immediately notify the COR upon discovery. Provide photos, location information, and cost proposals for corrective action.
3.7 UL Master Label Certification After all repairs are completed, the Contractor shall obtain UL Master Label recertification for each building s lightning protection system. 4. Applicable Codes and Standards NFPA 70 (NEC) NFPA 780 UL 96A ANSI/CAN/UL 96:2016 LPI 175 Applicable VA Design and Construction Standards 5. Roles and Responsibilities Contractor: Provide qualified personnel, materials, tools, equipment, and safety compliance. Complete inspections, repairs, reporting, and certification coordination. KCVA Facilities: Provide site access and coordination. Review reports and support scheduling. UL Representative: Perform evaluations and issue required Master Label certifications. 6. Quality Assurance and Safety Comply with OSHA, NFPA 70, NFPA 70E, and medical center safety policies. Use appropriate fall protection for elevated work. Maintain clean and orderly work areas. Remove debris daily. Ensure all work meets standards for quality and workmanship. 7. Site Visit A pre-bid site visit shall be conducted. All potential offerors are strongly encouraged to attend. Observable deficiencies identified will be documented and provided via the Contracting Officer. 8. Deliverables Initial inspection Inspection report with documented deficiencies and photos Correction of all deficiencies Follow-up report with before-and-after photos UL Master Label recertification

More opportunities from Department Of Veterans Affairs → 255-NETWORK Contract Office 15 (36C255)

Same awarding agency

NAICS: 236220
New
Federal
Z2DA--657-27-103JB, FCA Replace Building 51 Roof, JB
Solicitation # 36C25527Q0044
The Department of Veterans Affairs, Network Contracting Office 15, is conducting market research through a Sources Sought Notice to determine the availability of qualified Service-Disabled Veteran-Owned Small Business (SDVOSB) firms for a construction project at the St. Louis Medical Center Jefferson Barracks. The project involves the replacement of the roof and associated components for Building 51, covering approximately 56,000 square feet. The scope includes installing a 70-mil thermoplastic polyolefin (TPO) roofing system, replacing four skylights, and updating the penthouse roof-access ladder to meet OSHA and VA safety standards. The estimated value of the resulting contract is between 2 million and 5 million dollars, with a required performance period of 222 calendar days from the Notice to Proceed. The project requires the contractor to manage work within an occupied 24/7 facility, necessitating a detailed phasing plan and strict adherence to infection control and HVAC-intake protection. Key technical requirements include providing a 20-year no-dollar-limit warranty, ensuring positive drainage to prevent standing water for more than 48 hours, and submitting as-built record drawings in searchable PDF and editable CAD formats. Interested firms must be registered in SAM.gov under NAICS code 236220 and provide a capability statement by November 9, 2026, including evidence of CVE certification, bonding capability, and a history of comparable work performed within the last five years.
Commercial and Institutional Building Construction

POSTED

about 16 hours ago

DEADLINE

in 11 days
View Details

Find Active Opportunities Like This

Get AI-powered intelligence on the opportunities still open

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS