Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, October 28 at 2:00 PM ET

Register Free →

This Sources Sought opportunity from Department Of Veterans Affairs was posted on June 22, 2020. The submission period has ended. Browse the details below for market research, or find similar active opportunities.

H966--Fume Hoods Service Maintenance/Repair

Closed
36C24220Q0793Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

Active Opportunities Like This One

General Info

NAICS

335210 - Small Electrical Appliance Manufacturing

Place of Performance

Department of Veterans Affairs James J. Peters VA Medical Center 130 West Kingsbridge Road, Bronx, NY, 10468, USA

Set-Aside

NONE

Documents

1

36C24220Q0793.docx

DOCX

AI Contract Breakdown

Uniform Contract Format

Contract not broken down yet

CLEATUS splits the solicitation into Uniform Contract Format (UCF) sections: scope, pricing, deliverables, and evaluation criteria.

Timeline

PhaseClosed
Posted

Sources Sought

Response Deadline

Deadline has passed

Submission Closed

Find active opportunities like this

Start your free trial to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyDepartment Of Veterans Affairs → 242-NETWORK Contract Office 02 (36C242)
Contacts1 person available
OfficeALBANY, NY, 12208, USA
Office AddressALBANY, NY, 12208, USA
Contacts
Kodjovi A AtiklaKodjovi A. Atikla

Full Description

Show more
Please note that this is NOT a request for quotes or proposals, the Government is seeking information for market research purposes only. Network Contracting Office (NCO) 2/RPO East of the Department of Veterans Affairs is currently conducting a market survey for qualified firms capable of providing Fume Hoods Full Service which will include: all labor, personnel, supervision, equipment, tools, and all materials necessary to perform preventive maintenance, repair and certification on the chemical fume hoods, biological safety cabinets, laminar flow clean benches, and pharmacy clean rooms at The James J. Peters VA Medical Center, 130 W. Kingsbridge Road, Bronx, NY 10468. The North American Industry Classification Systems (NAICS) is 335210. Responses to this notice must be submitted in writing (email) and must be received no later than June 29, 2020 at 17:00 Email: Kodjovi.atikla2@va.gov No telephone inquiries will be accepted. Interested parties MUST provide company/individual name, a capability statement, examples of same or similar work performed at other facilities, DUNS number and address, point of contact and social-economic. Interested parties who do not submit the above information on or before the response due date and time will not be considered for this procurement. Fume Hoods Service Maintenance/Repair is required for a Base plus four (4) options years. The frequency of the Preventive Maintenance (PM) is Semi-annual (6 months). There are approximately 100 hoods in total. Chemical Fume Hoods are to be tested in accordance with OSHA, AIHA/ANSI. Hoods are to be certified semiannually as required. Primary test to be performed are inflow velocity profiling as per ANSI/AIHA Z9.5-2003 American National Standards for Laboratory Ventilation 6.3.3 Face Velocity Tests. The average face velocity shall be determined by the method described in the ANSI/ASHRAE 110-1995 Method of Testing Performance of Laboratory Fume Hoods. Face velocity measurements shall be made by dividing the hood opening into equal area grids with sides measuring no more than 12 in. (30.5 cm). The tip of the probe shall be positioned in the plane of the sash opening and fixed (not handheld) at the approximate center of each grid. Grid measurements around the perimeter of the hood opening shall be made at a distance of approximately 6 in. (15.2 cm) from the top, bottom, and sides of the opening enclosure. The average face velocity shall be the average of the grid velocity measurements. Each grid velocity shall be the average of at least 10 measurements made over at least 10 seconds. The plane of the sash shall be located at the midpoint of the sash frame depth. ANSI/ASHRAE 110-1995 ASHRAE Guideline: Method of Testing Performance of Laboratory Fume Hoods. 6.2 Face Velocity Measurement. A 1.0 ft2 imaginary grid pattern shall be formed by equally dividing the design hood opening into vertical and horizontal openings. Velocity readings shall be taken with a calibrated anemometer. For Variable Air Volume box (VAV) hoods, measurements should be made at 25, 50, and 100% sash openings. A hood is considered certified when the average face velocity at twelve inches working sash height is between 80 120 feet per minute. Testing for Pharmacy equipment shall be performed in accordance with USP Chapter 797; CETA CAG-002; and ISO14644-1:1999 standards and requirements for proper operation of this equipment with regard to minimizing potential contamination and exposure during sterile compounding and preparation of hazardous drugs. Biological Safety Cabinets are to be tested in accordance to field tests specified in NSF/ANSI 49-2008 Annex F as follows: F.2 Downflow Velocity F.3 Inflow Velocity (Face Velocity) Test F.4 Airflow Smoke Patterns Test F.5 HEPA Filter Leak Test F.6 Pressure Decay/Soap Bubble F.7 Site Installation Assessment Tests F.8 Electrical Leakage and Ground Circuit Resistance and Polarity Tests F.9 Lighting Intensity Test F.10 Vibration Test F.11 Noise Level Tests Laminar Flow Clean Benches are to be tested in accordance to field tests specified in IEST-RP-CC002.4 as follows: a. Airflow Velocity b. Filter Pressure Drop c. HEPA/ULPA Filter Leak Test d. Induction Leak Test e. Airborne Particle Count f. Lighting Intensity Test g. Noise Level Test Routine performance tests shall be conducted at least semi-annually or whenever a significant change has been made to the operational characteristics or relocation of the equipment. After successful testing Contractor will affix to the Safety Cabinets a Certificate of Operating Performance that indicates the date, unit tested, standards used, test report number, due date for next test and the service tech. Contractor will provide a test report identifying all tests performed, test results, and any adjustments or repairs that were made. Upon completion of certification testing Contractor will affix to the fume hood a Fume Hood Inspection tag that indicates the test date, due date for next certification, test report number, and service tech. Contractor will provide a test report identifying all tests performed, test results, and any adjustments or repairs recommended. A hood that is found to be operating with an average face velocity more than 10% below the designated average face velocity shall be labeled as OUT OF SERVICE and the technician shall notify the VA immediately so corrective actions can be taken by VA staff to increase flow. Each hood shall be posted with a notice giving the date of the routine performance test, the measured average face velocity and initialed by the technician. If it is taken OUT OF SERVICE, it shall be posted with an out-of-service notice. Repair Procedures: The contractor must be able to respond to emergency repairs within one business day in order to restore equipment back to first-class operating condition. Contractor will make allowances for revisits for clean room and hood certification due to failure to certify. Contractor will schedule certification of the equipment once repairs have been completed. Pharmacy Clean Room Re-certifications: the contractor shall conduct bi-annual testing in 1B-01 (1st Floor)), and 3C-08 (3rd Floor) Pharmacy Clean Room Suites using a CETA/CNBT certified technician to document USP 797 and USP 800 compliance. Testing will include viable and non-viable parameters, video filming of smoke patterns, and issuance of a comprehensive report, smoke-test video on DVD, and recertification certificate for each area, as well as documentation of technician s certification and calibration documents for equipment used during testing. Contractor will promptly notify JJP facility if any portion of the testing is out of compliance and will repeat that portion once corrections have been made before issuing comprehensive report. Contractor will provide technical expertise to in-house staff if needed, including adjustment and troubleshooting of equipment, and will install new HEPA Filters purchased by the JJP facility as needed to maintain compliance. Non-viable testing: Air Velocities/Volume and Uniformity Test HEPA Filter Leak Test Airborne Particle Counts Room Pressurization Noise Level Test Light Level Test Smoke pattern filming of rooms and hoods to document air flows Viable testing: 1st Floor Suite, 20 samples including controls/recertification Bacterial & Fungal Air Samples Bacterial & Fungal Surface/Touch Samples 3rd Floor Suite, 12 samples including controls/recertification Bacterial & Fungal Air Samples Bacterial & Fungal Surface/Touch Samples The purpose of this notice is to gain knowledge of potential qualified sources and their size classification/socioeconomic status (service-disabled veteran owned small business, veteran owned small business, women owned small business, HUB Zone, 8(a), small business or large business), relative to NAICS 335210 Responses to this notice will be used by the Government to make appropriate acquisition decisions. A solicitation is not currently available. If a solicitation is issued, it will be announced on at a later date, and all interested parties must respond to that solicitation announcement separately from the responses to this announcement.

More opportunities from Department Of Veterans Affairs → 242-NETWORK Contract Office 02 (36C242)

Same awarding agency

NAICS: 238220
New
Federal
W045--Boiler Rental
Solicitation # 36C24227Q0042
The Department of Veterans Affairs, Network Contracting Office 02, is seeking a firm-fixed price contract for the temporary rental of a 1000 HP Fire tube Steam Boiler at the VA Hudson Valley Healthcare System Montrose Campus. The primary objective is to maintain N+1 compliance for the Building 20 Central Utilities Plant. The period of performance is scheduled from November 1, 2026, through March 31, 2027. The selected vendor will be responsible for the delivery, setup, integration into an existing 95 PSIG steam grid, ongoing maintenance, and eventual removal of the equipment. All work must adhere to VA regulations, the VHA Safety Device Testing Manual, and Boiler Plant Directive 1810. Amendment 0001 updated the solicitation by removing clauses 52.219-6 and 52.219-14 and scheduling a site visit for October 19, 2026, at 10:00 am at the Montrose Campus, Building 16 Engineering Conference Room. Quotes are due by October 21, 2026, and will be evaluated based on price, technical capability, and past performance, with the latter two combined being equal in weight to price. Offerors must provide a technical capability statement of no more than 10 pages, a certificate of liability insurance, and three relevant past performance references. The vendor is also required to provide two internal boiler inspection reports, one prior to delivery and one at the end of the rental period.
Plumbing, Heating, and Air-Conditioning Contractors

POSTED

1 day ago

DEADLINE

in about 5 hours
View Details
NAICS: 621511
New
Federal
Q301--FY27 (BASE+4) STAT Laboratory Testing - Syracuse (VA-27-00010334)
Solicitation # 36C24227Q0069
The Department of Veterans Affairs VISN 2 Network Contracting Office intends to award a firm fixed-price contract for STAT laboratory testing services at the Syracuse VA Medical Center. The proposed contract structure includes a base period followed by four option periods. The government intends to sole source this requirement to University Pathologists Laboratories under FAR 6.302-1(a)(2), though this special notice serves as market research to identify other capable providers, including various small business socioeconomic categories. The scope of work involves the 24/7, 365-day-a-year analysis, monitoring, and reporting of clinical and surgical specimens, utilizing advanced methods such as electron microscopy and molecular studies. Key operational requirements include picking up specimens within 30 minutes of a request and delivering final written reports within five working days. Critical results require immediate notification to authorized providers. To be eligible, the contractor must employ board-certified pathologists and accredited technologists and maintain mandatory certifications, including a NYS Department of Health Clinical Laboratory Permit, a CLIA license, and CAP or Joint Commission accreditation. This acquisition falls under NAICS code 621511. Interested parties must provide documentation of their technical expertise and socioeconomic status to the contracting officer within 10 calendar days of the notice publication.
Medical Laboratories

POSTED

1 day ago

DEADLINE

in 9 days
View Details
NAICS: 811210
New
Federal
J065--FY27 Q2 SERVICES (BASE+4) Globus NYH Service Contract (VA-27-00004429)
Solicitation # 36C24227Q0068
The Department of Veterans Affairs Network Contracting Office 2 intends to award a sole source contract to Globus Medical, Inc. for the annual preventative maintenance, corrective maintenance, and repair of proprietary Global Surgical Equipment. This includes the ExcelsiusGPS robotic system and ExcelsiusE3D system. The services will be performed at the VA New York Harbor Healthcare System's Manhattan and Brooklyn campuses. The base period of performance is scheduled from January 1, 2027, to December 31, 2027, with the possibility of four additional option years. The procurement falls under NAICS code 811210 for Electronic and Precision Equipment Repair and Maintenance, which has a small business size standard of 34 million dollars. It is noted that Globus Medical, Inc. has an exclusive authorized Service-Disabled Veteran Owned Small Business partner, SDV Office Systems, LLC, for sales of this equipment to federal government facilities. While this is a notice of intent for a sole source award, interested firms may submit written notification and supporting evidence of their ability to perform the requirements to Kaitlyn Morgan via email by October 27, 2026, at 12:00 p.m. EST. The government maintains sole discretion on whether to compete the procurement based on the responses received.
Electronic and Precision Equipment Repair and Maintenance

POSTED

1 day ago

DEADLINE

in 6 days
View Details
NAICS: 541330
New
Federal
C1DA--NRM A/E- 528A7-27-112 Fire Alarm Panel Upgrade
Solicitation # 36C24227Q0070
The Department of Veterans Affairs, through Network Contracting Office 02, has issued a Request for Information to identify qualified Architect-Engineer firms for the upgrade of an obsolete Edwards EST-3 fire alarm system at the Syracuse VA Medical Center in New York. This is a sources sought notice and not a formal solicitation for proposals. The scope of work involves providing complete design and cost estimation services, including the upgrade of fire alarm control panels and remote annunciators, the installation of a new master control panel and fiber loop network, the expansion of the addressable system to additional campus buildings, and the removal of the existing fireman telephone system. The selected firm must also develop a phasing plan to ensure continuous fire alarm protection during construction and provide construction period services. A critical requirement for this project is that the prime firm must have a registered Fire Protection Engineer (FPE) on staff, and all drawings must be stamped by an FPE with no exceptions. All designs must comply with the latest editions of NFPA 70, NFPA 72, and the NEC, as well as applicable VA construction standards and fire protection design criteria. This opportunity falls under NAICS code 541330 for Engineering Services. Interested and capable sources must submit a written capability statement to the designated contract specialist by November 3, 2026, at 10:00 EST.
Engineering Services

POSTED

1 day ago

DEADLINE

in 13 days
View Details
NAICS: 811210
New
Federal
J065--Philips Imaging Equipment preventative maintenance and repair services at the Northport VA Medical Center
Solicitation # 36C24227Q0066
The Department of Veterans Affairs Network Contracting Office 2 has issued a Notice of Intent to Sole Source for a full-service agreement to provide preventative maintenance and repair services for Philips imaging equipment at the Northport VA Medical Center. The intended awardee is Philips Healthcare, identified as the original equipment manufacturer and the sole authorized licenser of the required equipment and software. The period of performance is scheduled from February 1, 2027, to January 31, 2028. The scope of work includes the provision of authorized technicians, OEM parts, labor, tools, remote diagnostic support, and software updates for a specific inventory of equipment, including a Vereos PET/CT, two Ingenuity Core 128 CTs, two Veradius Mobile C-arms, and two EPIQ ultrasound systems. This procurement falls under NAICS code 811210 for Electronic and Precision Equipment Repair and Maintenance, with a size standard of 34 million dollars. While the government intends to sole source the contract, interested parties may submit capability documentation and technical backgrounds to demonstrate their ability to satisfy the requirements by October 28, 2026. All prospective contractors must be registered in the System for Award Management to be eligible for award. Responses must be submitted via email to the contract specialist, Lynn Krakowiak, using the specified subject line for the solicitation number 36C24227Q0066.
Electronic and Precision Equipment Repair and Maintenance

POSTED

1 day ago

DEADLINE

in 7 days
View Details

Find Active Opportunities Like This

Get AI-powered intelligence on the opportunities still open

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS