HVAC Replacement, Bldg. 2821
Contract Overview
Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.
AI Contract Overview
The 4th Contracting Squadron at Seymour Johnson Air Force Base is soliciting a firm-fixed-price contract for the removal of an existing HVAC unit and the installation of a new 2-ton split heat pump system in Room 2821. The required system must have a minimum 14 SEER efficiency rating and a 10 kW electric heat strip, with American Standard or an approved equivalent specified as the preferred make. The scope of work includes all necessary personnel, materials, and equipment to complete the installation and perform associated interior architectural restoration to wall surfaces affected during the process. The contractor is responsible for the lawful disposal of all construction debris and packaging materials off-base. This project is a total small business set-aside and must be completed within ten business days from the start of on-site work, adhering to standard base operational hours. Award will be based on best value, with equal weight given to price, technical plan, and past performance. The contractor must provide a minimum one-year workmanship warranty and comply with the Davis-Bacon Act and Nonappropriated Fund (NAF) contracting procedures. Key requirements include the provision of performance and payment bonds, adherence to Buy American Act certifications, and the submission of a detailed technical plan covering site preparation, removal, replacement, restoration, and final testing. Responses are due by October 28, 2026.
General Info
Place of Performance
NCSet-Aside
Timeline
Response Deadline
Organization & Contact Information
Full Description
The Contractor shall provide all personnel, management, supervision, tools, materials, equipment, transportation, and incidentals necessary to remove, furnish, and install a complete split heat pump system and perform associated interior architectural restoration in Room 2821 at Seymour Johnson Air Force Base.
Purpose
The overall objective of this project is to deliver reliable, efficient climate control to Room 2821 and restore adjacent interior wall surfaces affected during equipment and line set routing.
Similar Contracts
Same NAICS industry code
More opportunities from Department Of Defense → FA4809 4TH Cons Squadron Cc
Same awarding agency
Ready to Pursue This Opportunity?
Get AI-powered intelligence on this solicitation and the ones like it
Every page of the solicitation package shredded into a compliance breakdown
AI-powered matching based on your capabilities and past performance
Competitor and incumbent history on the requirement
Automated alerts on amendments, Q&A deadlines, and award
Join 750+ contractors already using CLEATUS