Show more

This subcontract opportunity involves the removal of existing HVAC equipment and the installation of a new 2-ton split heat pump system for prime contractors at Seymour Johnson Air Force Base. The scope of work includes the installation of a 10 kW electric heat strip, insulated copper refrigerant line sets, and a commercial programmable thermostat. The selected contractor is responsible for all evacuation, vacuum testing, and commissioning to ensure the delivery of a fully operational system. Managed by the Department of Defense under the 4th Cons Squadron Cc, this project is designated as a total Small Business Set Aside under NAICS code 238220. The solicitation was posted on October 21, 2026, with a response deadline of October 28, 2026.

General Info

HVAC removal and 2-ton heat pump installation at Seymour Johnson Air Force Base.

NAICS

238220 - Plumbing, Heating, and Air-Conditioning Contractors

Place of Performance

NC

Set-Aside

SBA

Documents

This scope was carved out of FA4809AWHVAC.

The full solicitation package (5 documents), including the RFP, is on the prime solicitation, not on this scope.

View the prime solicitation

HVAC Replacement, Bldg. 2821

AI Contract Breakdown

Uniform Contract Format

No documents to break down

The breakdown needs solicitation documents. None were found from this contract's source.

Timeline

Posted

subcontract

Response Deadline

Submission deadline

Response Deadline

Ready to pursue this opportunity?

Start your free trial to track this contract, build proposals with AI assistance, and manage your pipeline.

Organization & Contact Information

Show more
AgencyDepartment Of Defense → FA4809 4TH Cons Squadron Cc
ContactsNo contacts available
OfficeN/A
Office AddressN/A
ContactsNo contact information available

Full Description

Show more
Performs removal of existing HVAC equipment and installation of a new split heat pump system for prime contractors on Air Force base projects at Seymour Johnson AFB. Installs a 2-Ton heat pump split system, 10 kW electric heat strip, insulated copper refrigerant line set, and commercial programmable thermostat. Performs evacuation, vacuum testing, and commissioning. Delivers a fully operational, commissioned 2-ton split heat pump system.

Similar Contracts

Same NAICS industry code

NAICS: 238220
New
WOJC - Multi-Building Plumbing Leak Repair Project
Solicitation # WOJC – Multi-Building Plumbing Leak Repair Project
Education and Training Resources is seeking quotes for a multi-building plumbing leak repair project at the Westover Job Corps Center in Chicopee, Massachusetts. The scope of work includes replacing leaking shower P-trap drain pipes in Rooms 123 and 213, repairing a cracked drain pipe in the pipe chase of Room 216, and replacing approximately ten linear feet of leaking heat pipe sections in both the Administration Building and King Hall. All work must comply with the Massachusetts State Plumbing Code, International Plumbing Code, and all applicable federal, state, and local regulations. Contractors are required to maintain a clean work area with daily debris removal and must provide all warranties, guarantees, and a signed punch list to close the project. Bids are due by 4:00 PM on October 30, 2026, and must include a detailed cost breakdown of labor and materials, a proposed service schedule, and a quote valid for at least 60 days. Award selection is not based solely on the lowest price; ETR will evaluate bids based on cost, technical approach, and qualifications. Required submission documents include a current SAM.gov UEI number, active registration confirmation, Massachusetts licensing, a W-9, a signed Vendor Acknowledgement Form, and certificates of liability insurance. Depending on the project value, payment and performance bonds may be required for contracts exceeding 35,000 dollars. Compliance with the Davis-Bacon Act and Service Contract Act is mandatory, including the submission of weekly certified payroll reports.
Westover Job Corps Center

POSTED

about 7 hours ago

DEADLINE

in 7 days
View Details
NAICS: 238220
New
MI 2026-14 Emergency Heating and Air Conditioning Services
Solicitation # MI 2026-14
Adams and Associates, Inc., contracting for the U.S. Department of Labor, is soliciting bids for emergency heating and air conditioning services at the Miami Job Corps Center in Florida. The period of performance runs from November 1, 2026, to October 31, 2027. The scope of work involves emergency HVAC repairs, requiring vendors to provide separate hourly rates for non-emergency daytime services and emergency, weekend, and holiday services. Bids must be submitted on company letterhead by October 23, 2026, and must remain valid for 90 days. Award selection is based on the most responsible bidder, with cost being a significant factor, though the lowest bid does not guarantee selection. Eligible vendors must maintain an active SAM.gov registration and a valid Unique Entity ID. Required submission documents include a Vendor Questionnaire, W9, Authority to Commit, a Certificate of Liability Insurance, and all necessary business and employee licenses for the State of Florida. Insurance requirements include Workers Compensation and Comprehensive General Liability of at least 1,000,000 dollars per occurrence. The contract is subject to the Service Contract Act and Davis-Bacon Act, with a minimum wage of 13.65 dollars per hour applicable through December 31, 2026. Additionally, vendors must adhere to strict center security protocols, including prohibited fraternization with students and mandatory security screenings. Payment terms are NET 30 days from the date of invoice.
Miami Job Corps Center

POSTED

about 7 hours ago

DEADLINE

in about 11 hours
View Details
NAICS: 238220
New
CBP6585 Bldg. 22 HVAC Replacement
Solicitation # CBP6585
Management & Training Corporation (MTC) is seeking bids for a fixed-price, single lump sum subcontract to remove and replace the HVAC equipment serving Building 22 at the San Diego Job Corps Center in Imperial Beach, California. This small business set-aside opportunity, categorized under NAICS 238220, requires the contractor to provide all labor, materials, equipment, and permits necessary for completion. Key deliverables include two sets of operation and maintenance manuals and manufacturer and installer warranties. Bids are evaluated based on overall best value, and a mandatory physical site visit and signature on the attendance roster are required prior to submission. The project is subject to the Davis-Bacon Act, requiring adherence to prevailing wage rates and fringe benefits, as well as compliance with OSHA safety standards and the provision of personal protective equipment for all site entrants. For bids equal to or greater than $25,000, a bid bond of 20% of the base bid is required, and the awarded contractor must provide performance and payment bonds totaling 100% of the contract price from a surety with at least an A- rating. Required submission documents include a detailed cost breakout, proof of insurance, three professional references, a completed MTC Supplier Packet, and a Unique Entity ID (UEI) number upon notice of intent to award. Payment is based on percentage of completion using AIA Document G702 and G703 forms, with weekly certified payroll submissions required.
San Diego Job Corps Center

POSTED

about 7 hours ago

DEADLINE

in 6 days
View Details
NAICS: 238220
New
MJCC EXHAUST FANS BLD. 1429
Solicitation # mjcc-exhaust-fans-bld-1429
Insights Training Group LLC, on behalf of the Muhlenberg Job Corps Center, is soliciting fixed-price quotes from qualified HVAC and mechanical contractors to restore the exhaust fan and louver systems in Building 1429 located in Kentucky. The scope of work includes a variety of repairs across multiple units, specifically replacing the selector switch and motor for Fan 2, relocating the thermostat for Fan 3, replacing the motor for Fan 4, installing a missing motor, blade, and guard for Fan 5, verifying the operation of Fan 6, and replacing the louver actuator for Fan 7. All work must adhere to applicable building codes, manufacturer requirements, and OSHA and EPA regulations. The contract will be awarded to the responsible offeror who provides a technically acceptable quote at the lowest price. This is a small business set-aside opportunity open to VOSB, SDVOSB, WOSB, and HUBZone certified entities. Proposals must be submitted by October 30, 2026, and must include a detailed scope of work, line-item pricing for labor and materials, equipment specifications, and proof of Kentucky state registration and licensing. Additionally, contractors must demonstrate the ability to secure performance and payment bonding and provide proof of insurance before commencing work. Compliance with the Davis-Bacon Act and certified payroll wage rate requirements is mandatory. Contractors are required to submit weekly certified payroll with every invoice to receive payment, and final payment is contingent upon the delivery of a release from liens by all subcontractors and suppliers. The project concludes with a substantial completion walk-through and a final acceptance inspection, requiring the delivery of all operating manuals, training, and a completed punch list.
Muhlenberg Job Corps Center / Insights Training Group LLC

POSTED

about 7 hours ago

DEADLINE

in 7 days
View Details

More opportunities from Department Of Defense → FA4809 4TH Cons Squadron Cc

Same awarding agency

NAICS: 238220
New
Federal
HVAC Replacement, Bldg. 2821
Solicitation # FA4809AWHVAC
The 4th Contracting Squadron at Seymour Johnson Air Force Base is soliciting a firm-fixed-price contract for the removal of an existing HVAC unit and the installation of a new 2-ton split heat pump system in Room 2821. The required system must have a minimum 14 SEER efficiency rating and a 10 kW electric heat strip, with American Standard or an approved equivalent specified as the preferred make. The scope of work includes all necessary personnel, materials, and equipment to complete the installation and perform associated interior architectural restoration to wall surfaces affected during the process. The contractor is responsible for the lawful disposal of all construction debris and packaging materials off-base. This project is a total small business set-aside and must be completed within ten business days from the start of on-site work, adhering to standard base operational hours. Award will be based on best value, with equal weight given to price, technical plan, and past performance. The contractor must provide a minimum one-year workmanship warranty and comply with the Davis-Bacon Act and Nonappropriated Fund (NAF) contracting procedures. Key requirements include the provision of performance and payment bonds, adherence to Buy American Act certifications, and the submission of a detailed technical plan covering site preparation, removal, replacement, restoration, and final testing. Responses are due by October 28, 2026.
Plumbing, Heating, and Air-Conditioning Contractors

POSTED

1 day ago

DEADLINE

in 6 days
View Details

Ready to Pursue This Opportunity?

Get AI-powered intelligence on this solicitation and the ones like it

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS