Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, November 11 at 2:00 PM ET

Register Free →

Hydrostatic and Axial Spring Rate Testing

Open
Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

General Info

NAICS

541380 - Testing Laboratories and Services

Place of Performance

TN, 37389, USA

Set-Aside

NONE

Documents

This scope was carved out of FA9101LDFDB.

The full solicitation package (2 documents), including the RFP, is on the prime solicitation, not on this scope.

View the prime solicitation

Large Diameter Flex Duct Bellows

AI Contract Breakdown

Uniform Contract Format

No documents to break down

The breakdown needs solicitation documents. None were found from this contract's source.

Timeline

Posted

subcontract

Response Deadline

Submission deadline

Response Deadline

Ready to pursue this opportunity?

Get full access to track this contract, build proposals with AI assistance, and manage your pipeline.

Organization & Contact Information

Show more
AgencyDepartment Of Defense → FA9101 Aedc Pkp Procrmnt Branch
ContactsNo contacts available
OfficeN/A
Office AddressN/A
ContactsNo contact information available

Full Description

Show more
Performs hydrostatic pressure and axial spring rate testing for prime contractors on Arnold AFB projects. Conducts hydrostatic testing to 45 psig at 70°F per ASME Boiler and Pressure Vessel Code and calculates axial spring rate performance. Utilizes hydrostatic test pumps and axial load testing apparatus. Delivers pressure test inspection reports, spring rate results, and visual inspection reports.

Similar Contracts

Same NAICS industry code

NAICS: 541380
New
Federal
Sources Sought for Geotechnical Exploration for U.S. Army Corps of Engineers, St. Louis District
Solicitation # W912P927Z2401
The U.S. Army Corps of Engineers, St. Louis District, is conducting market research via a Sources Sought Notice to identify qualified contractors for geotechnical exploration services. The anticipated contract is an Indefinite Delivery Indefinite Quantity (IDIQ) with Firm-Fixed-Price (FFP) terms, featuring a total value not to exceed 5 million dollars. The scope of work involves collecting subsurface condition data through land-based or overwater drilling and sampling to depths of up to 200 feet. While the primary focus is within Missouri and Illinois, work may extend to the Mississippi Valley Division or other continental U.S. locations. Key technical requirements include the use of Bentley Systems OpenGround and KeyLAB software, adherence to EPA guidelines for hazardous waste sites, and the implementation of a Job Safety Hazard Analysis Plan. The anticipated period of performance is a basic ordering period of five years, with a government option to extend services by an additional six months, totaling a maximum duration of five years and six months. Interested SAM-registered businesses under NAICS 541380 must submit a capability statement by December 8, 2026, to Mary Ann Coventry. Submissions must include business details, socio-economic status, and documentation proving the ability to bond projects up to 5 million dollars as a prime contractor. Additionally, firms should provide up to three project examples demonstrating relevant experience, detailing the work self-performed versus the percentage subcontracted.
W07V Endist St Louis

POSTED

about 9 hours ago

DEADLINE

in 28 days
View Details
NAICS: 541380
New
SLED
Fire Flow Testing Services
Solicitation # 121589
The Washington Suburban Sanitary Commission (WSSC Water) is soliciting sealed responses for Solicitation No. 121589 to establish a requirements contract for Fire Flow Testing Services. The contractor will be responsible for the planning, locating, inspection, and testing of fire hydrants and associated water distribution system components across various pressure zones in Maryland. The scope of work includes measuring static pressure, residual pressure, and flow rates, as well as performing hydrant and valve inspections. All work must adhere to AWWA standards, WSSC Water requirements, and Maryland Department of the Environment regulations regarding chlorinated water discharge. The contract consists of a one-year base term with the option for four additional one-year extensions. To be considered, bidders must meet strict minimum qualifications, including at least five years of experience in fire flow testing and the ability to provide at least two crews. Each crew must have a lead with three years of experience, and at least one crew member must hold a current Maryland Water Distribution System Operator D-1 license. Bidders must also provide a comprehensive equipment list and a Quality Assurance/Quality Control plan. The contract will be awarded to the lowest responsive and responsible bidder. Submissions are due by November 30, 2026, at 2:00 pm via the WSSC eProcurement Portal and must include all required certifications, insurance documentation, and a detailed pricing proposal for estimated quantities of tests and inspections.
Utility Services Department

POSTED

about 23 hours ago

DEADLINE

in 20 days
View Details

More opportunities from Department Of Defense → FA9101 Aedc Pkp Procrmnt Branch

Same awarding agency

NAICS: 332996
New
Federal
Large Diameter Flex Duct Bellows
Solicitation # FA9101LDFDB
The Department of Defense, through the Arnold Engineering Development Complex at Arnold AFB, Tennessee, has issued a Sources Sought Notice to identify capable businesses for the procurement of two new, fully functional Large Diameter Flex Duct Bellows Assemblies. These assemblies must feature a 45.315-inch internal diameter and be fabricated from silicone-coated 1523 fiberglass with a 6-ply body and a nominal thickness of 0.12 inches. The technical requirements specify a working pressure of 30 psid internal and 15 psid external, with an operational temperature range from -60°F to +450°F. Fabrication must adhere to EJMA Standards, ASME Boiler and Pressure Vessel Code, and Drawing RJ632279.18, with welds inspected per AWS D1.1. Refurbished or remanufactured parts are strictly prohibited. The contractor is responsible for all materials, labor, equipment, and transportation, including the provision of supports, cribbing, tie downs, and weather protection to ensure safe delivery to Arnold AFB. Required deliverables include a comprehensive documentation package consisting of visual, weld, and pressure test inspection reports, axial spring rate calculations, and a standard manufacturer warranty. Assemblies must undergo hydrostatic testing to 45 psig at 70°F. Interested respondents must submit their company information, SAM Unique Entity Identifier, Cage Code, business size, and a tailored capability statement to the designated points of contact by November 19, 2026.
Fabricated Pipe and Pipe Fitting Manufacturing

POSTED

about 9 hours ago

DEADLINE

in 9 days
View Details
NAICS: 332912
New
Federal
Tunnel 9 Pitch Upgrade
Solicitation # FA9101T9PU
The Arnold Engineering Development Complex (AEDC) requires the comprehensive modernization of a high-performance hydraulic motion system for Tunnel 9 located in Silver Spring, Maryland. This 100% Small Business Set-Aside is a Firm-Fixed-Price contract encompassing the design, engineering, procurement, off-site fabrication, pre-assembly, on-site demolition, installation, and commissioning of core system components. Key hardware requirements include a primary control valve with a step response time of 55 ms or less, a main actuating cylinder with a 120.5-inch working stroke capable of 13 ft/s linear speed, a Hydraulic Power Unit (HPU), and a dedicated filtration and cooling kidney loop. All components must adhere to ASME B31.1, ASME BPVC VIII, and ISO 4406 standards, with specific requirements for near-vacuum environment reliability and compatibility with DTE-26 Ultra hydraulic oil. The project is structured into three distinct phases: Engineering Design, Part Procurement and Pre-assembly, and Demolition, Installation, and Commissioning. The total period of performance is 46 weeks from the lead time event. Award will be based on a combination of technical capability, past performance on similar hydraulic systems, and price reasonableness. Contractors must meet CMMC Level 1 (Self) cybersecurity requirements and possess the ability to handle Controlled Unclassified Information (CUI). Rigorous quality controls are mandated, including hydrostatic pressure testing, live performance demonstrations witnessed by AEDC, and strict adherence to MIL-STD-130 and MIL-STD-129 for item marking and shipment. Payment will be processed electronically via the Wide Area WorkFlow (WAWF) system.
Fluid Power Valve and Hose Fitting Manufacturing

POSTED

4 days ago

DEADLINE

in 30 days
View Details
NAICS: 333517
New
Federal
Large CNC EDM Sinker
Solicitation # FA9101_LARGE_CNC_EDM_SINKER
The Department of Defense, through the Arnold Engineering Development Complex (AEDC) at Arnold Air Force Base, Tennessee, has issued a Sources Sought Notice to identify capable small and large businesses for the procurement of a new, fully functional Large CNC EDM Sinker. This requirement strictly prohibits the use of refurbished or remanufactured parts. The selected contractor must provide all materials, labor, and equipment to deliver the machine FOB Arnold Air Force Base, with a required delivery timeline of four months from the receipt of order. The scope includes installation at the Model Shop in Building 451, supervised by factory-trained servicemen, and the provision of two days of formal training for three individuals on machine controls and operation. Technical specifications require the machine to be built to NFPA 79 standards and compatible with a 480V, 3PH, 60 HZ power system. Post-delivery, the contractor must perform functional accuracy tests according to ISO/ANSI standards, ensuring repeatability and positioning within +/- .0001”. The contract includes a 24-month warranty on materials and workmanship, a ten-year accuracy guarantee on the Linear Drive System, and strict support requirements, including a 36-hour on-site repair response time and 48-hour delivery for repair parts. Interested respondents must submit company information, SAM data, a capabilities statement, a rough-order-of-magnitude budgetary estimate, and a projected delivery schedule by November 13, 2026.
Machine Tool Manufacturing

POSTED

5 days ago

DEADLINE

in 3 days
View Details

Earlier notices in this NAICS code

Posted before this notice, open and closed

Ready to Pursue This Opportunity?

Get AI-powered intelligence on this solicitation and the ones like it

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS