Machine Installation Supervision and Operator Training

Open
Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

AI Contract Overview

Show more

This subcontract, titled Machine Installation Supervision and Operator Training, supports prime contractors on Air Force Arnold Engineering Development Complex projects under the Department of Defense. The scope of work involves providing factory-trained servicemen to oversee on-site technical installation and conduct a formal two-day training session for three designated personnel. The contractor is responsible for performing functional accuracy tests in accordance with ISO/ANSI standards to ensure operational integrity. Final deliverables include the successful training of personnel and the submission of a verified accuracy report. The project is categorized under NAICS code 811210 and is performed in zip code 37389.

General Info

Subcontract for machine installation supervision, operator training, and accuracy testing for Air Force projects.

NAICS

811210 - Electronic and Precision Equipment Repair and Maintenance

Place of Performance

TN, 37389, USA

Set-Aside

NONE

Documents

This scope was carved out of FA9101_LARGE_CNC_EDM_SINKER.

The full solicitation package (2 documents), including the RFP, is on the prime solicitation, not on this scope.

View the prime solicitation

Large CNC EDM Sinker

AI Contract Breakdown

Uniform Contract Format

No documents to break down

The breakdown needs solicitation documents. None were found from this contract's source.

Timeline

Posted

subcontract

Response Deadline

Submission deadline

Response Deadline

Ready to pursue this opportunity?

Get full access to track this contract, build proposals with AI assistance, and manage your pipeline.

Organization & Contact Information

Show more
AgencyDepartment Of Defense → FA9101 Aedc Pkp Procrmnt Branch
ContactsNo contacts available
OfficeN/A
Office AddressN/A
ContactsNo contact information available

Full Description

Show more
Performs on-site technical supervision and operator training for prime contractors on Air Force Arnold Engineering Development Complex projects. Provides factory-trained servicemen to supervise installation and conduct a two-day formal training session for three personnel. Performs functional accuracy tests per ISO/ANSI standards. Delivers trained personnel and a verified accuracy report.

Similar Contracts

Same NAICS industry code

NAICS: 811210
New
SLED
950-791313 / Tops & PLC Maintenance
Solicitation # SRC0000037566
The State of Alabama, through the Sw Reg Gcw Tunnel Dist 95, is soliciting control systems support services for the period of October 1, 2026, through September 30, 2027. The scope of work involves monthly preventive and routine maintenance of Programmable Logic Controllers (PLC), Human Machine Interface (HMI), and Historian components at the Traffic Management Center complex. Key deliverables include monthly data backups for the Transportation Operation Performance System (TOPS) software, Factory Talk systems, and Historian databases, with all backups stored on redundant external hard drives. Additionally, the contractor must perform biannual hardware inspections for the Bankhead Tunnel, Wallace Tunnel, I-10 Bayway, Cochrane Bridge, and Bayou La Batre Bridge, while providing ongoing application development and updates for TOPS and PLC systems. Financial terms are structured as hourly billing for software maintenance and support across six specific line items for the tunnels and bridges, while hardware is billed as cost plus a percentage markup. The total contract cost is capped at 25,000 dollars, with the possibility of annual renewals for up to five years. All monthly maintenance must be completed within the first week of the month and accompanied by a maintenance report. The contract is governed by the Code of Alabama, including specific provisions for proration and non-appropriation of funds, and requires the supplier to certify tax compliance and the absence of collusion or debarment.
Sw Reg Gcw Tunnel Dist 95

POSTED

about 13 hours ago

DEADLINE

in 5 days
View Details
NAICS: 811210
New
SLED
RF Amplifier Module Repairs
Solicitation # 2101369
Dallas Area Rapid Transit is soliciting bids for a Blanket Purchase Order to provide repair services for CommScope Node A Bi-Directional RF Amplifier Modules used in its Tunnel Radio System. The scope of work specifically covers the repair of 700 MHz (DCM AF 7037) and 800 MHz (DCM AF 8037) amplifier modules. Qualified vendors must possess the necessary equipment to test and calibrate these modules in their normal working configuration using a CommScope Node A Chassis to ensure they meet original manufacturer specifications. Repaired units must be returned within 120 days of receipt and include detailed repair reports documenting findings and test results. A minimum six-month warranty is required for all repairs, covering workmanship and replacement parts. Units deemed Beyond Economical Repair must be returned with supporting documentation, for which DART will pay reasonable evaluation and shipping fees. To be considered responsive, bidders must register and submit all completed and signed solicitation documents via the Bonfire portal. Pricing must be comprehensive, including all costs for labor, materials, freight, and pick-up. Payment terms are set at 30 days from the receipt of the invoice or order, whichever is later, and the Authority is exempt from Texas state and local sales and use taxes. Vendors must adhere to strict compliance standards, including certifications regarding foreign terrorist organizations, anti-boycott of Israel policies, and conflict of interest disclosures. Inspection and acceptance of the repaired modules will occur at the destination address in Dallas, Texas.
Dallas Area Rapid Transit

POSTED

about 17 hours ago

DEADLINE

in 5 days
View Details

More opportunities from Department Of Defense → FA9101 Aedc Pkp Procrmnt Branch

Same awarding agency

NAICS: 811310
New
Federal
PES E-Unit Footer Repair
Solicitation # FA9101_PESEUNITREPAIR
The Air Force Test Center is issuing a Sources Sought Notice to identify capable small and large businesses for emergency structural thread repair and precision mechanical alignment of an Allis Chalmers 1409 axial compressor at the Arnold Engineering Development Complex in Arnold AFB, Tennessee. The project involves lifting an 80,000 lbf compressor unit to repair stripped 2-1/2 inch-8 hold down threads on four footers, replacing 16 bolts with hardware that meets or exceeds original specifications, and performing a cold alignment of the complete drive system. The scope of work is divided into two CLINs covering the lift and repair process and the subsequent reconnection of the compressor to the motor and aft compressor. The government requires the work to be completed within 15 workdays or no later than December 15, 2026. The contractor is responsible for providing the necessary crane for lifting the unit and couplers, and must submit a detailed lift plan five working days prior to the operation. A site visit is required before the contract award. Interested respondents must provide their company information, SAM Unique Entity Identifier, and a brief description of their technical approach to meet the requirements by November 10, 2026. This notice is for informational purposes to determine market capability and does not constitute a formal solicitation or request for quote.
Commercial and Industrial Machinery and Equipment (except Automotive and Electronic) Repair and Maintenance

POSTED

about 19 hours ago

DEADLINE

in 5 days
View Details
NAICS: 333517
New
Federal
Large CNC EDM Sinker
Solicitation # FA9101_LARGE_CNC_EDM_SINKER
The Department of Defense, through the Arnold Engineering Development Complex (AEDC) at Arnold Air Force Base, Tennessee, has issued a Sources Sought Notice to identify capable small and large businesses for the procurement of a new, fully functional Large CNC EDM Sinker. This requirement strictly prohibits the use of refurbished or remanufactured parts. The selected contractor must provide all materials, labor, and equipment to deliver the machine FOB Arnold Air Force Base, with a required delivery timeline of four months from the receipt of order. The scope includes installation at the Model Shop in Building 451, supervised by factory-trained servicemen, and the provision of two days of formal training for three individuals on machine controls and operation. Technical specifications require the machine to be built to NFPA 79 standards and compatible with a 480V, 3PH, 60 HZ power system. Post-delivery, the contractor must perform functional accuracy tests according to ISO/ANSI standards, ensuring repeatability and positioning within +/- .0001”. The contract includes a 24-month warranty on materials and workmanship, a ten-year accuracy guarantee on the Linear Drive System, and strict support requirements, including a 36-hour on-site repair response time and 48-hour delivery for repair parts. Interested respondents must submit company information, SAM data, a capabilities statement, a rough-order-of-magnitude budgetary estimate, and a projected delivery schedule by November 13, 2026.
Machine Tool Manufacturing

POSTED

about 19 hours ago

DEADLINE

in 8 days
View Details
NAICS: 334418
New
Federal
ENETX-MA4
Solicitation # FA910127QB002
Solicitation FA910127QB002 is a combined, firm-fixed-price procurement for the Department of the Air Force, specifically supporting the 704th Test Group and 746th Test Squadron at Holloman Air Force Base, New Mexico. The primary objective is the acquisition of manufactured commercial hardware to support the integration, maintenance, and troubleshooting of the Ultra High Accuracy Reference System and customer Units Under Test. The required deliverables include two ENETX-MA4-2F4 Converter Appliances, two ENETXCAB-MA4-J1-01 interface cable assemblies for power and MIL-STD-1553, and two ENETXCAB-MA4-J2-02 interface cable assemblies for ARINC-429. All equipment must be RoHS compliant and adhere to the Alta dt Hardware Manual. This procurement is a 100% Small Business Set-Aside for brand-name items, specifically requiring genuine OEM Alta dt parts; offers of alternate brands will be deemed technically unacceptable. Award will be granted to a responsible source that is technically acceptable and provides a fair and reasonable price, with a 10 percent price evaluation preference applied to HUBZone small business concerns. Delivery is required within 10 weeks from the date of award receipt, with shipping terms set as FOB Destination. The contract incorporates various FAR and DFARS clauses, including those regarding the Buy American program, safeguarding covered defense information, and prohibitions on certain procurements from the Xinjiang Uyghur Autonomous Region and the Maduro regime. Quotes must be submitted electronically by November 20, 2026, and must include a total firm-fixed-price quote and confirmation of active SAM.gov registration.
Printed Circuit Assembly (Electronic Assembly) Manufacturing

POSTED

3 days ago

DEADLINE

in 14 days
View Details
NAICS: 332912
New
Federal
Tunnel 9 Pitch Upgrade
Solicitation # FA9101T9PU
The Arnold Engineering Development Complex (AEDC) is seeking a small business contractor for the comprehensive modernization of a high-performance hydraulic motion system at Tunnel 9 in Silver Spring, Maryland. This Firm-Fixed-Price requirement is a 100% Small Business Set-Aside and follows a three-phase execution model: Phase 1 covers engineering and design; Phase 2 involves manufacturing, testing, and delivery; and Phase 3 encompasses the disassembly of the existing system, installation, start-up, and commissioning. The total period of performance is 46 weeks from the date of award. The scope of work requires the design, procurement, fabrication, and installation of core components, including a Hydraulic Power Unit, a dedicated filtration and cooling kidney loop, a main actuating cylinder with a 120.5-inch working stroke and 13 ft/s linear speed, and a primary control valve with a step response time of 55 ms or less. All deliverables must adhere to ASME B31.1, ASME BPVC VIII, and ISO 4406 standards. Contractors must provide weld inspection certifications and material certifications of conformance. Award will be based on the most advantageous offer, evaluating technical capability on an acceptable/unacceptable basis, followed by an assessment of past performance and price reasonableness. Security requirements include CMMC Level 1 (Self) certification and the ability to access Controlled Unclassified Information. Final acceptance will occur at the Silver Spring site following successful integration and verification testing.
Fluid Power Valve and Hose Fitting Manufacturing

POSTED

3 days ago

DEADLINE

in about 9 hours
View Details

Ready to Pursue This Opportunity?

Get AI-powered intelligence on this solicitation and the ones like it

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS