Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, October 28 at 2:00 PM ET

Register Free →

This Government Contract opportunity from International Boundary And Water Commission: Us-Mexico was posted on October 1, 2024. The submission period has ended. Browse the details below for market research, or find similar active opportunities.

Influent Magnetic Meter Replacement

Awarded
20244321004Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

Active Opportunities Like This One

NAICS: 221320
New
Federal
Y--GRCA 257282 - Replace Wastewater Plant at South Ri
Solicitation # 140P2026R0101
Solicitation 140P2026R0101 is an unrestricted full and open competition issued by the National Park Service, DSC Contracting Services Division, for the replacement of the South Rim Wastewater Treatment Plant at Grand Canyon National Park, Arizona. This design-bid-build project involves the installation of a GD Membrane Bio-Reactor wastewater treatment plant, including new process facilities, instrumentation and control systems, electrical infrastructure, and administrative support buildings. The scope of work encompasses comprehensive site preparation, grading, paving, fencing, and improvements to the facility access road, as well as the complete demolition and removal of existing infrastructure once the new plant is accepted. The project includes a 12-month operational support period and requires strict adherence to Department of the Interior cybersecurity requirements, ADA and ABA accessibility standards, and union prevailing wage rates. The contract is a firm-fixed-price award with a magnitude of construction exceeding 100 million dollars. The period of performance is scheduled from February 1, 2027, to February 1, 2030, with a total performance duration of 1095 calendar days after the notice to proceed. Award selection will be based on a multi-factor, best-value tradeoff process evaluating technical experience, past performance, and proposed pricing. Offerors must provide performance and payment bonds and identify key personnel, including a Project Manager, Superintendent, and specialists in quality control, safety, and historic preservation. Proposals are submitted in two volumes, with technical evaluations focusing on the relevance of project experience and the contractor's capability to manage a project of this scope and complexity.
Dsc Contracting Services Division

POSTED

1 day ago

DEADLINE

in 21 days
NAICS: 221320
Federal
Operations and Maintenance (O&M) Services for the SBIWTP
Solicitation # 191BWC26R0009
Solicitation 191BWC26R0009, issued by the International Boundary and Water Commission, seeks a contractor to provide Firm Fixed Price Operations and Maintenance (O&M) services for the South Bay International Wastewater Treatment Plant (SBIWTP) in San Ysidro, California. The contract is structured with a base year running from June 1, 2027, to May 31, 2028, and multiple option years extending through May 2031. A primary objective of the scope is managing plant operations, SCADA systems, and maintenance during the facility's expansion from 25 MGD to 50 MGD. The contractor must ensure 24/7 staffing, including a bilingual operator, and maintain strict compliance with the National Pollutant Discharge Elimination System (NPDES) permit and other regional water quality board regulations. Award will be based on the Highest Technically Rated with a Fair and Reasonable Price method, where non-price factors—such as plant operations, permit compliance, and staffing—are significantly more important than cost. Key requirements include the designation of a Project Manager, Superintendent, Site Safety and Health Officer, SCADA Specialist, and Asset Manager. The contractor is responsible for a wide array of deliverables, including a Phase-In Plan, Preventative Maintenance Plan, and monthly performance reports. Security is a high priority, requiring background investigations for personnel and adherence to NIST standards for protecting Controlled Unclassified Information. Performance will be monitored via a Quality Assurance Surveillance Plan focusing on regulatory compliance, uptime, and effluent quality.
Internat Boundary And Water Commission

POSTED

8 days ago

DEADLINE

in 2 months
NAICS: 221320
Federal
Waste Water Treatment Plant Services
Solicitation # FA448627Q0002
Solicitation FA448627Q0002 is a Request for Quotation issued by the Department of the Air Force for Waste Water Treatment Plant Services at Lajes Field in Praia da Vitoria, Azores, Portugal. The contractor will be responsible for the operation and maintenance of a waste water treatment plant with a capacity of 800,000 gallons per day, as well as the associated lift station, oil-water separator, and grease traps. Key requirements include providing a Lead Operator with a Level II or higher WPI Certification and at least three years of experience, implementing a 52-week preventive maintenance plan, and ensuring compliance with ISO/IEC 17025 laboratory standards and Portuguese decree law 183/2009 for waste landfills. The scope also encompasses corrosion control, painting, and the management of hazardous materials. The government intends to award a single Firm-Fixed-Price contract with a total duration not to exceed 66 months, consisting of a base period and four option periods. This is an unrestricted acquisition, and proposals must be submitted electronically by November 23, 2026, at 14:00 Azores Time. Offers are evaluated through a three-step sequential process: an administrative compliance review, a technical acceptability evaluation based on experience, approach, and a quality control plan, and finally a price evaluation in Euro currency. Award is contingent upon the availability of funds. Payments will be processed electronically via the Wide Area WorkFlow system.
FA4486 765 Abs Conf

POSTED

16 days ago

DEADLINE

in 26 days

AI Contract Overview

Show more

The International Boundary and Water Commission awarded a contract to Clean Infusion LLC in the amount of 122,180.73 dollars for the replacement of the influent magnetic flow meter at the Nogales International Wastewater Treatment Plant located in Rio Rico, Arizona. This project, designated as a total small business set-aside under NAICS code 221320, involves the removal of an inoperable meter and the installation of a Flo-System Model 253 or an equivalent unit capable of interfacing with the existing SCADA system. The scope of work includes project management, the installation of temporary bypass lines to handle peak flows of approximately 22 mgd, and the installation of a 30-inch magnetic flowmeter. Technical requirements specify that the equipment must meet strict manufacturing and calibration standards, including NIST traceability and FM approval for Class I, Div. 2 environments. The contract is governed by a Quality Assurance Surveillance Plan to monitor contractor performance and adheres to U.S. Department of Labor Wage Determination 2015-5481 for labor rates in Santa Cruz County. Deliverables for the project include a comprehensive Project Work Plan and a one-year warranty on the installed system.

General Info

Agency

International Boundary And Water Commission: Us-Mexico

Contract Value

$122,180.73

NAICS

221320 - Sewage Treatment Facilities

Place of Performance

Rio Rico, AZ, 85648, USA

Set-Aside

SBA

Award Issued Date

Documents

10

Fischer Porter Model 10D1435A Magnetic Flowmeter Instruction Bulletin

PDF, High priority: read this firstspecifications
High

Fischer PortSeries Manufacturing Specifications - Order 890A5510J0001

PDF, High priority: read this firstspecifications
High

Influent Magnetic Meter Replacement CLIN Structure

PDF, High priority: read this firstspecifications
High

Magnetic Flow Measuring Systems Specifications

PDF, High priority: read this firstspecifications
High

NIWTP Replace Mag Meter - Quality Assurance Surveillance Plan (QASP)

PDF, High priority: read this firstqasp
High

Project No. S4 - Sectional Plan

PDF, High priority: read this firstspecifications
High

PWS - Replace Influent MAG Meter (NIWTP)

PDF, High priority: read this firstsow
High

Site Image - Magmeter and Potential Bypass Points

PDF, High priority: read this firstspecifications
High

Wage Determination 2015-5481

PDF, High priority: read this firstwage-determination
High

20244321004 NIWTP Replacement of Mag Meters - Q&A

PDF, Low priorityq-and-a
Low

AI Contract Breakdown

Uniform Contract Format

Contract not broken down yet

CLEATUS splits the solicitation into Uniform Contract Format (UCF) sections: scope, pricing, deliverables, and evaluation criteria.

Timeline

4 updates
PhaseAwarded
Posted

Combined Synopsis

Notice updated

Response deadline changed from Aug 12, 2024 to Aug 26, 2024. The notice description changed.

Notice updated

The notice description changed.

Notice updated

The notice description changed.

Notice updated

The notice description changed.

Awarded

Contract was awarded

Submission Closed

Find active opportunities like this

Get full access to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyInternational Boundary And Water Commission: Us-Mexico
Contacts2 people available
OfficeEl Paso, TX, 79902, USA
Organization / Agency
International Boundary And Water Commission: Us-Mexico
Office AddressEl Paso, TX, 79902, USA
Contacts
Seone Michael Jones
Adrian Knights

Full Description

Show more
Note - Images added ---------------------------------------------------------- Note - Final set of questions posted as an attachment along with Site Image. ---------------------------------------------------------- Note - Attachement S4.pdf drawing added. -------------------------------------- Note - Response to the question received is provided and specification document attached. Due date for offers has been extended to August 26, 2024. Q1 - I see some details on the existing flow meter to be removed, however there is not details on the replacement flow meter. Do you have specifications for the new equipment? If you can provide the diameter at the least I should be able to get you a quote for a replacement flow meter. A1 - See attachment mg meter specs.pdf ----------------------------------------------------------------- This is a combined synopsis/solicitation for commercial items in accordance with the format in FAR Subpart 12.6, as supplemented with additional information included in this notice. This announcement constitutes the only solicitation; quotes are being requested and a written solicitation will not be issued separately. This solicitation document and its incorporated provisions and clauses are those in effect through Federal Acquisition Circular (FAC) 2024-05 dated May 22, 2024. The solicitation number is 20244321004 this solicitation is issued as a request for quote (RFQ). The requirement is for replacement of the current Inflow magnetic flow meter as per plant maintenance and repair manuals for the International Boundary and Water Commission, Nogales International Wastewater Treatment Plant (NIWTP), located at 865 East Frontage Road, Rio Rico, Arizona, 85648. This is a 100% Small business Set Aside, request for quote (RFQ). The associated North American Industry Classification System (NAICS) code is 221320 Sewage Treatment Facilities, with a corresponding small business standard of $35,000,000.00. The Product Service Code (PSC) for this requirement is N047 Installation of Equipment- Pipe, Tubing, Hose, and Fittings. Only offers from SAM registered businesses will be considered for this solicitation. Services shall be quoted ALL or NONE as per CLIN structure attached and returned with your quote via e-mail directly to my attention at contact@example.gov with 20244321004 Influent Magnetic Flow Meter in the subject line. Quotes shall be good for 120 Days. Site visit will be held on July 31, 2024, 11AM. Attending the site visit of where the work will be performed is highly recommended - pictures are allowed but no pictures of other attendees or IBWC personnel are allowed. PPE is required - hard hat and protective footwear. The USIBWC will not provide PPE. Site visit Point of Contact is Mr. Albert Flores, +1 (555) 000-0000. Please be aware that whatever is said during the meeting is meant to be helpful but does not and cannot change the Solicitation Documents. During this site visit, all conversations are considered informal and are not contractually binding until questions are submitted in written form. The official answers will be posted to SAM.gov for all. All questions arising from the site visit should be directed to the Contracting POC ONLY via email. PLEASE SEND ALL QUESTIONS TO SEONE MICHAEL JONES at contact@example.gov. Only questions submitted by email to contact@example.gov will be considered. Questions received from Offerors after 2PM on August 5, 24, may not be responded to. REFERENCE 202443210004 NIWTP REPLACEMENT OF MAG METERS IN THE SUBJECT LINE ON ALL COMMUNICATIONS. Offer due date/local time: August 26, 2024; 2:00 PM MST. Active UEI (Unique Entity Identifier) must be included with your offer. Only questions submitted by email to contact@example.gov will be considered. Questions received from Offerors after 2PM on 8/5/24, may not be responded to. Description: The International Boundary and Water Commission, United States Section (IBWC) requires the replacement of the Train 1 Bioreactor Diffusers, two Blowers and 4 RAS Pumps for the International Boundary and Water Commission, Nogales International Wastewater Treatment Plant (NIWTP), located at 865 East Frontage Road, Rio Rico, Arizona, 85648. Refer to attached PWS for description of the requirement to include dates and places of delivery, inspection, and acceptance. CLIN structure attached shall be returned with your quote via email to my attention with information requested. The destination for FOB Destination shall be the Nogales Field Office. Evaluation of Offer - The Government will award a contract resulting from this combined synopsis/solicitation to the responsible offeror whose offer conforming to the solicitation will be most advantageous, best value to the Government, price and other factors considered. The following factors shall be used to evaluate Offers: Technical acceptability to meet IBWC requirements; Technical Approach and Past Performance. Award will be made to the responsible offeror whose offer represents the Best Value to the Government, in consideration of all factors. The following factors will be used to determine the most advantageous offeror to the Government: 1) ability to meet the technical and performance requirements listed in the PWS; 2) ability to meet the experience requirements listed in the PWS and Section L of the RFQ; 3) ability to meet the period of performance requirements (180 days) and 4) price. Offerors shall include a completed copy of the provision at 52.212-3, Offeror Representations and Certifications-Commercial Items, with its offer. NOTE: The offeror shall complete only paragraph (b) of this provision if the Offeror has completed the annual representations and certification electronically via the System for Award Management (SAM) website accessed at https://www.sam.gov. END of combined synopsis/solicitation Attachments: CLIN Structure - Train 1 Diffuser Performance Work Statement Quality Assurance Surveillance Plan (QASP) Wage Determination 2015-5481 Revision # 23

Earlier notices in this NAICS code

Posted before this notice, open and closed

Find Active Opportunities Like This

Get AI-powered intelligence on the opportunities still open

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS