Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, December 9 at 2:00 PM ET

Register Free →

This Subcontract opportunity from Department Of Veterans Affairs was posted on March 17, 2026. The submission period has ended. Browse the details below for market research, or find similar active opportunities.

Integrated Electrophysiology Mapping System Supply

Closed
Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

Active Opportunities Like This One

NAICS: 334510
New
Federal
6540--NX EQ Ophthalmic: Image Digitization System (VA-26-00079075)
Solicitation # 36C10B26Q0747
The Department of Veterans Affairs, through the Technology Acquisition Center, has issued a Request for Information (RFI) for the Zeiss FORUM Image Digitization System: Ophthalmic. This brand-name software and hardware solution is intended for the Veterans Health Administration to acquire, digitize, store, view, and print ophthalmic images from devices such as fundus cameras and fluorescein angiography instruments. The system requirements include digital CCD cameras, image enhancement processors, and electronic storage and printing capabilities. The anticipated period of performance consists of a 12-month base period followed by four 12-month option periods for continued support services. As this is a market research effort, the RFI does not constitute a formal solicitation or a guarantee of a future contract. Interested respondents must provide company identification, CAGE numbers, and NAICS code 334510 details, along with socioeconomic certifications regarding small business status and compliance with FAR and VAAR regulations, including Service-Disabled Veteran-Owned Small Business set-asides. Responses must be no longer than four pages and include details on any existing GSA or GWAC schedules. Submissions are to be sent to the Contract Specialist, Kalil O'Neal, via the SAM.gov portal or email.
Technology Acquisition Center Nj (36C10B)

POSTED

1 day ago

DEADLINE

in 3 days
NAICS: 334510
New
SLED
Single Plane Interventional Radiology Imaging System
Solicitation # 2140866
SBH Health System is soliciting proposals for a new single-plane interventional X-ray imaging system to replace a decommissioned unit at St. Barnabas Hospital in New York. The system will support embolization procedures, stent placement, and coronary and peripheral angiography. The comprehensive scope of work includes the delivery, rigging, and installation of the equipment, removal of the existing unit, onsite staff training, and a three-year service and warranty term. This procurement is funded in whole or in part by a federal award from the Health Resources and Services Administration and is subject to 2 CFR Part 200 regulations. Proposals are due by December 10, 2026, and the period of performance is scheduled from September 30, 2026, through September 29, 2027. Award decisions will be based on the proposal determined most advantageous to the health system, with a heavy emphasis on technical compliance and operational continuity. Evaluation factors include the compatibility of system controls with existing workflows, the efficiency of the staff training plan, and the ability to provide functional backup or loaner equipment during maintenance. Qualified offerors must provide FDA clearance for all components, certify they are not excluded from federal programs via the HHS OIG/LEIE list, and complete the VendorMate credentialing process. SBH encourages participation from small, minority-owned, women-owned, and veteran-owned businesses, while giving preference to products manufactured in the United States.
SBH Health System

POSTED

1 day ago

DEADLINE

in 23 days

AI Contract Overview

Show more

This subcontract, managed by the Department of Veterans Affairs Network Contract Office 16, concerns the supply of the Affera Integrated Mapping System. This specialized equipment is designed for use in cardiac electrophysiology procedures to provide real-time heart mapping capabilities. The opportunity was posted on March 17, 2026, with a response deadline of March 24, 2026. Classified under NAICS code 334510, the contract focuses on the procurement of advanced medical instrumentation to support cardiac care within the agency's network.

General Info

NAICS

334510 - Electromedical and Electrotherapeutic Apparatus Manufacturing

Place of Performance

MS

Set-Aside

NONE

Documents

This scope was carved out of 36C25626Q0522.

The full solicitation package (1 document), including the RFP, is on the prime solicitation, not on this scope.

View the prime solicitation

6515--Notice of Intent to Sole Source - Affera Mapping Ablation Medtronic USA, INC.

AI Contract Breakdown

Uniform Contract Format

No documents to break down

The breakdown needs solicitation documents. None were found from this contract's source.

This one is closed. Find the next one like it.

Open contracts like this one, right now:

  • Supplier of Reusable Temperature Monitoring Probes (NSN 6515-01-614-6436)Open now, due in 6 days
  • Special Purpose Electrical Cable Assembly (NSN 6150-01-632-4855)Open now, due in 15 days
See open contracts like this

Ask CLEATUS

I've read this contract. Ask me anything.

Timeline

PhaseClosed
Posted

subcontract

Response Deadline

Deadline has passed

Submission Closed

Find active opportunities like this

Get full access to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyDepartment Of Veterans Affairs → 256-NETWORK Contract Office 16 (36C256)
ContactsNo contacts available
OfficeN/A
Office AddressN/A
ContactsNo contact information available

Full Description

Show more
Supply of the Affera™ Integrated Mapping System used in cardiac electrophysiology procedures for real-time heart mapping.

More opportunities from Department Of Veterans Affairs → 256-NETWORK Contract Office 16 (36C256)

Same awarding agency

NAICS: 237110
New
Federal
Y1DZ--598-22-115 Site Utility Infrastructure-NLR
Solicitation # 36C25626R0084_1
The Department of Veterans Affairs is soliciting a firm-fixed-price contract to upgrade and replace the site utility infrastructure at the Eugene J. Towbin VA Healthcare Center in North Little Rock, Arkansas. This project, identified as Project 598-22-115, involves the demolition of an existing 250,000-gallon water tower and the installation of a new elevated water storage tank, a new pump house with integrated controls and emergency power, and an upgraded site distribution system. The period of performance is 720 calendar days from the issuance of the Notice to Proceed. This procurement is a 100% set-aside for Service-Disabled Veteran-Owned Small Businesses (SDVOSB). To be eligible, offerors must be verified in the Small Business Association's Veteran Small Business Certification (VetCert) system and registered in the System for Award Management (SAM). The government will utilize a Past Performance-Price Tradeoff approach for award, where past performance is considered significantly more important than price. Proposals must be submitted in two distinct volumes—Past Performance and Price/Award Documents—via email to the contract specialist. Key requirements include the provision of performance and payment bonds totaling 100% of the award amount and strict safety certifications, including OSHA 30-hour training for superintendents and OSHA 10-hour training for all site employees. Additionally, contractors must maintain an Insurance Experience Modification Rate (EMR) of 1.0 or less to avoid disqualification. Technical specifications mandate strict adherence to NRTL, NFPA, and OSHA standards, with specific marking and labeling requirements for all installed equipment and valves.
Water and Sewer Line and Related Structures Construction

POSTED

about 9 hours ago

DEADLINE

in about 2 months
View Details
NAICS: 513210
New
Federal
Service Plan/Agreement for InVita Healthcare Technologies (brand) Unique Device Identifier (UDI) Tracker Software Platform, South Central VA Health Care Network, 715 S. Pear Orchard Road, Ridgeland, MS 39157
Solicitation # 36C25627Q0083
The Department of Veterans Affairs, specifically the South Central VA Health Care Network, is soliciting a firm, fixed-price contract for a service plan and agreement for the InVita Healthcare Technologies Unique Device Identifier (UDI) Tracker Software Platform. This platform is utilized across seven facilities, including the Southeast Louisiana Veterans Health Care System, G.V. (Sonny) Montgomery VA Medical Center, and Overton Brooks VA Medical Center. The scope of work includes maintenance, licensure, and support for a web-based system that tracks tissue and implants from receipt through patient implantation and recall matching. Key technical requirements include integration with the VISTA Scheduling Module and CPRS, the ability to automatically populate Interop notes, and compliance with FDA regulations and Joint Commission standards. The solicitation is unrestricted and open to all contractors, provided they are an authorized, certified, or designated Original Equipment Manufacturer (OEM) provider. Award will be granted to the lowest-priced contractor that meets all technical specifications. The contract includes a base period from February 1, 2027, to January 31, 2028, with multiple option years extending through January 31, 2032. Proposals must be submitted in three separate PDF volumes: Technical, Price, and Addendum. Contractors must provide an OEM authorization letter and maintain an active SAM registration to be eligible. Performance is expected during normal business hours, and the contract incorporates specific FAR clauses regarding commercial services, insurance for government installations, and security prohibitions.
Software Publishers

POSTED

about 9 hours ago

DEADLINE

in 3 days
View Details
NAICS: 339112
New
Federal
6515--RFI: Neuro SURGIX VS Spinal Curettes MEDVAMC
Solicitation # 36C25627Q0153
The Department of Veterans Affairs, Network Contracting Office 16, is conducting market research via a Sources Sought Notice to identify qualified manufacturers and authorized distributors for spinal curettes and curette trays. These items are intended for clinical use at the Michael E. DeBakey VA Medical Center in Houston, Texas. The requirement specifically seeks Chroma-style spinal curettes in both straight and 40-degree angled configurations, spanning sizes 2-0 through 6-0 with specific color coding, as well as compatible trays capable of holding ten curettes in 9-inch and 10-inch lengths. All products must be genuine commercial items free of defects and sourced through authorized channels. This notice is for information purposes only and does not constitute a formal solicitation or a commitment to award a contract. The VA is utilizing this process to determine competitive source availability, fair market pricing, and the applicability of the Veterans First program. Responses are being gathered under NAICS code 339112, with a strong encouragement for SBA-certified Service-Disabled Veteran-Owned Small Businesses (SDVOSB) and Veteran-Owned Small Businesses (VOSB) to respond. Interested parties must provide capability information, non-binding budgetary quotes, and certifications regarding the Nonmanufacturer Rule (NMR) to assist the government in developing an independent cost estimate and acquisition strategy.
Surgical and Medical Instrument Manufacturing

POSTED

1 day ago

DEADLINE

in 3 days
View Details
NAICS: 238220
New
Federal
Z2NZ--Turn Key Chiller Equipment (Purchase and Install)
Solicitation # 36C25627Q0087
Solicitation 36C25627Q0087 is a total Service-Disabled Veteran-Owned Small Business (SDVOSB) set-aside for the turnkey replacement of an OR package chiller at the Alexandria Veterans Affairs Health Care System in Pineville, Louisiana. The project involves the removal and legal disposal of an existing unit and the installation of a new 120-ton Trane Air-Cooled Scroll Packaged Chiller (model CGAM120). Key technical requirements include electrical reconnection per National Electrical Code, piping insulation, and recharging the chilled water loop with a 30% glycol-water mixture. Startup and commissioning must be performed by an authorized Trane Service provider to maintain warranty validity, which includes one year for parts and labor and five years for the compressor. The estimated contract magnitude is between $100,000 and $250,000, structured as a firm-fixed-price lump sum. Performance must begin within 10 calendar days of a formal Notice to Proceed, with onsite construction to be completed within 30 calendar days. Award will be based on a Best Value tradeoff strategy evaluating four factors: Management Approach, Schedule, and Quality Management (Factor I); Professional Qualifications and Specialized Experience (Factor II); Past Performance (Factor III); and Price (Factor IV). Factors I, II, and III are equal in importance and collectively carry approximately the same weight as the price factor. Offerors must submit a consolidated PDF proposal including a bid bond, EMR data, and evidence of SDVOSB certification.
Plumbing, Heating, and Air-Conditioning Contractors

POSTED

1 day ago

DEADLINE

in 15 days
View Details
NAICS: 811210
New
Federal
J061--Eaton Battery Replacement & Preventative Maintenance
Solicitation # 36C25627Q0152
The Department of Veterans Affairs is conducting market research via a Sources Sought Notice to identify qualified contractors for the Michael E. DeBakey VA Medical Center in Houston, Texas. The requirement involves a comprehensive preventative maintenance evaluation and the replacement of all batteries for an Eaton 93PM-160-200 Uninterruptible Power Supply (UPS). The selected contractor must provide all necessary labor, tools, and OEM parts, ensuring that the UPS is placed in bypass mode to avoid interrupting MRI operations. A critical requirement is that all services be performed by Eaton manufacturer-trained technicians with current factory certification. Additionally, the contractor is responsible for the environmentally responsible recycling and removal of old batteries from the facility. The government anticipates a single-award, firm-fixed-price contract with all services to be completed within 60 days after the award. Work is generally expected to occur during normal business hours, though the contractor must have the capability to work weekends or after-hours if approved by the Contracting Officer Representative. The project falls under NAICS code 811210 for Electronic and Precision Equipment Repair and Maintenance. Interested firms must submit a capabilities statement including company identification, socioeconomic status, and evidence of their ability to meet the technical requirements and security standards, including compliance with VA cybersecurity and confidentiality regulations.
Electronic and Precision Equipment Repair and Maintenance

POSTED

1 day ago

DEADLINE

in 1 day
View Details
NAICS: 811310
New
Federal
J061--586-Switchgear and ATS Investigation and Repair Service (VA-27-00015294)
Solicitation # 36C25627Q0085
Solicitation 36C25627Q0085 is a firm-fixed-price contract issued by the Department of Veterans Affairs for investigation and corrective repair services for the MV switchgear system and Automatic Transfer Switches (ATS) at the G.V. Sonny Montgomery VA Medical Center in Jackson, Mississippi. This total set-aside for Service-Disabled Veteran-Owned Small Businesses (SDVOSB) requires the contractor to provide all labor, tools, and materials to restore reliable power distribution by inspecting and repairing GE Main switchgear, ABB Distribution switchgear, and ASCO ATS-1 and ATS-2. Key tasks include replacing trip/close coils, repairing defective relays such as G-30, Multilin, and ABB series, and correcting wiring faults. The contractor is responsible for delivering an investigation report, a repair completion report, an updated device condition log, and recommendations for future reliability improvements. The performance period is scheduled from November 30, 2026, to January 29, 2027. All work must comply with OSHA and Joint Commission Standards, with breaker testing performed according to NFPA 70 B and E. While the facility utilizes CAT generators (650 kw and 2250 kw), load banking is only required for investigative or repair verification purposes, and authorized CAT service companies may perform these tasks without direct CAT factory involvement. Award will be made to the responsible offeror based on the Lowest Priced Technically Acceptable (LPTA) criteria, requiring a capability statement and three past performance references from the last three years.
Commercial and Industrial Machinery and Equipment (except Automotive and Electronic) Repair and Maintenance

POSTED

4 days ago

DEADLINE

in 1 day
View Details
NAICS: 238290
New
Federal
N099--JLM Roll Up Door Replacement
Solicitation # 36C25627Q0092
The Department of Veterans Affairs, Network Contracting Office 16, is soliciting quotes for solicitation number 36C25627Q0092 to replace a motorized roll-up door at the John L. McClellan Veterans Hospital in Little Rock, Arkansas. This is a 100 percent Service-Disabled Veteran-Owned Small Business (SDVOSB) set-aside under NAICS code 238290. The project requires the contractor to provide all labor, tools, and equipment, including a scissor lift and forklift, to remove the existing door and install one grey 7 by 9 foot motorized rolling steel rapid slat door with insulated slats and an obstruction safety device. The contract will be awarded as a firm-fixed-price agreement with a performance period of 30 days from the Notice to Proceed and includes a one-year warranty. Quotations will be evaluated using the Lowest Price Technically Acceptable (LPTA) process. To be eligible, offerors must be certified SDVOSBs in the SBA database and provide a plan demonstrating that the SDVOSB prime, alone or with similarly situated SDVOSB subcontractors, will perform at least 50 percent of the cost for personnel. Submissions must be emailed to Joseph Warren by 3:00 PM CST on November 18, 2026, and must include a technical capability description, a completed price schedule, and the VAAR 852.219-75 Notice. A site visit was scheduled for November 6, 2026, and all work must comply with OSHA ANSI/CAN/UL standards.
Other Building Equipment Contractors

POSTED

5 days ago

DEADLINE

in 3 days
View Details

Earlier notices in this NAICS code

Posted before this notice, open and closed

Find Active Opportunities Like This

Get AI-powered intelligence on the opportunities still open

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS