J--Emergency Generator PM Repair / BMS/ 9/26/19 TO 9/25/24 IDIQ contract

Awarded
36C24519Q0346Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

Active Opportunities Like This One

NAICS: 811310
New
Kubota M8200 Clutch Replacement
Solicitation # kubota-m8200-clutch-replacement
Management and Training Corporation is soliciting lump sum fee proposals for the clutch replacement of a Kubota M8200 tractor with front wheel assist, located at the Earle C. Clements Job Corps Center in Morganfield, Kentucky. The scope of work requires a qualified contractor to provide all transportation, labor, materials, and equipment to diagnose and repair the clutch assembly and power take-off system. Key technical requirements include replacing friction discs, bearings, oil seals, and O-rings, resurfacing the flywheel, and replacing hydraulic pipes and filters as needed. The contractor must perform all work according to manufacturer specifications and provide a final summary of diagnostic findings, an itemized list of replaced parts, and warranty documentation upon completion. This solicitation is set aside for small businesses, including VOSB, SDVOSB, WOSB, and HUBZone certified entities. Bids must be submitted via email to Angie Mahoney by 3:00 PM CST on November 3, 2026, and must include a bid sheet, proof of insurance, a completed supplier packet with a W-9, and applicable SBA certification letters. Award decisions will be based on best value, with a focus on administrative compliance and technical qualifications. The contract is subject to various Federal Acquisition Regulations, including standards for combating trafficking in persons, Buy American restrictions, and Service Contract Labor Standards per Wage Determination 2015-4687 Revision 31 for Kentucky.
Earle C. Clements Job Corps Center

POSTED

about 3 hours ago

DEADLINE

in 5 days
NAICS: 811310
New
SLED
ANNUAL ROTATING EQUIPMENT INSPECTION, TESTING, REPAIR, RECONDITIONING AND STORAGE SERVICES
Solicitation # 2026-RFP-130
Solicitation 2026-RFP-130, issued by the City of Lakeland, seeks qualified contractors to provide annual inspection, testing, repair, reconditioning, and storage services for critical rotating equipment at the McIntosh and Larsen Power Plants. The scope of work covers a wide range of industrial machinery, including low- and medium-voltage AC and DC electric motors, as well as circulating water and condensate pumps. Required services include clean inspect test (CIT) procedures, troubleshooting, motor rewinding, machining, welding, and dynamic field balancing. The contractor is also responsible for the pickup, transportation, and secure indoor storage of equipment, ensuring strict preservation measures such as periodic shaft rotation and moisture control to prevent corrosion and damage. The selection process is based on a points-based criteria to identify the vendor most responsive to the city's needs. Proposers must submit their responses via the OpenGov portal by October 30, 2026, and provide essential documentation including a signed W-9, Sunbiz registration, a notarized indemnification agreement, and a human trafficking affidavit. Contractors must adhere to strict safety standards, including OSHA compliance and specific certification for crane operations and critical lifts. Furthermore, vendors are required to maintain insurance policies with AM Best ratings of no less than A and must undergo a safety audit covering EMR and employee training records to ensure compliance with city risk management standards.
LE - Production - MPP

POSTED

about 7 hours ago

DEADLINE

in 8 days

AI Contract Overview

Show more

This IDIQ contract, managed by the Department of Veterans Affairs, covers the inspection and preventative maintenance of seven Cummins 750 KW emergency generators and 28 associated automatic transfer switches located at the Baltimore VA Medical Center and Loch Raven BRECC. The contractor is responsible for providing all labor, materials, and equipment to perform semi-annual inspections and annual comprehensive services, including oil and fuel analysis, filter changes, and four-hour load bank tests. Maintenance tasks include checking fuel systems, batteries, coolant additives, and simulating engine safeties to ensure operational readiness. The selected vendor must employ technicians with specialized training and at least five years of experience with comparable systems. A critical requirement of the contract is the ability to respond to emergency calls 24/7 and provide a temporary generator with full circuit connections within 48 hours of a system failure. All work must be coordinated with the VA Contracting Officer's Representative, and the contractor is required to provide detailed checklists of performed tests and written cost estimates for any recommended additional repairs.

General Info

Contract Value

$0

NAICS

811310 - Commercial and Industrial Machinery and Equipment (except Automotive and Electronic) Repair and Maintenance

Place of Performance

MD, USA

Set-Aside

NONE

Award Issued Date

Documents

0

No documents available

Documents will appear here when they are available.

AI Contract Breakdown

Uniform Contract Format

No documents to break down

The breakdown needs solicitation documents. None were found from this contract's source.

Timeline

1 update
PhaseAwarded
Posted

Presolicitation

Notice updated

The notice description changed.

Type Changed

Presolicitation → Solicitation

Awarded

Contract was awarded

Submission Closed

Find active opportunities like this

Get full access to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyDepartment Of Veterans Affairs → 245-NETWORK Contract Office 5 (36C245)
ContactsNo contacts available
OfficeLINTHICUM, MD, 21090, USA
Office AddressLINTHICUM, MD, 21090, USA
ContactsNo contact information available

Full Description

Show more
PURPOSE: This purchase request supports the inspection and regular preventative maintenance on the 6 Cummins 750 KW emergency generators and 27 associated ATS in Baltimore, 1 emergency generator and 1 ATS at Loch Raven BRECC. SCOPE OF WORK: The Contractor shall provide all personnel, management, material, parts, equipment, supplies, labor, area clean-up and transportation to perform: Two yearly Inspections and maintenance on six (6) emergency generators and one (1) at Loch Raven. Inspect the associated automatic transfer switches (ATS) and perform a 4-hour load bank test on (6) emergency generators at Baltimore VA Medical Center and 1 at Loch Raven located in Baltimore, MD. The contractor must employ mechanics and technicians that are trained in the applicable codes, standards, and manufacturer requirements for maintenance and repair of generators and ATSs. The contractor must have at least 5 years experience satisfactorily performing such maintenance on comparable units, equipment, or systems. Failure of VA owned generator equipment due to malfunctions beyond the vendor's control, the vendor must have the ability to respond to an emergency call 24/7 and have the means to provide a temporary generator and all necessary connections to the appropriate building circuits within forty-eight (48) hours of known failure delivered on site with hookup. Once per year: Oil changed and oil filter(s) changed on each generator. Oil analyzed before oil change. Diesel Fuel analyzed in each day tank. 4-hour load bank test on each emergency generator (7-each). The load bank testing must be coordinated with and approved by VA COR. Twice per year: Fuel tanks and lines to be inspected for the purpose of determining if excessive sludge or rust is collecting. All fuel filters and sediment bowls to be cleaned, or changed as per manufacturer recommendations. Check entire equipment for fuel or coolant leaks. Check the water pump, hoses and clamps, belts for damage. Check condition of batteries and report any action necessary for recharging or replacing. Add electrolytes as necessary. Not all batteries are sealed type. Check battery chargers for proper operation. Inspect air filters and make recommendation to replace or not. Check automatic transfer switches (27 each) for proper operation and lubricate all moving parts therein. Check all instruments for proper operation and simulate engine safeties for proper operation. Check supplemental coolant additives (SCA) and add proper amount of treatment for each cooling system. Test refill pumps inside of day tanks for proper operation. Check heater block system on generator. Provide check list to the COR of all checks performed and all test performed. After the complete maintenance procedure is accomplished, the vendor will make written recommendations of additional work/repairs if required. The vendor will clearly write the material/labor cost estimates of additional work/repairs. After each service on all of the above, run generator and conduct test under load. The test under load must be coordinated in advance and approved by COR.

More opportunities from Department Of Veterans Affairs → 245-NETWORK Contract Office 5 (36C245)

Same awarding agency

NAICS: 561210
New
Federal
J044--NOTICE OF INTENT TO SOLE SOURCE Baltimore VAMC Steam System Preventive Maintenance from Vicinity Energy Baltimore Corporation
Solicitation # 36C24527Q0048
The Department of Veterans Affairs is issuing a Notice of Intent to Sole Source for an open market award to Vicinity Energy Baltimore Corporation to provide annual steam system preventive maintenance at the Baltimore VA Medical Center. This requirement, classified under NAICS code 561210 and PSC J044, is driven by the fact that the facility's steam equipment is directly connected to the district steam distribution system owned and operated by Vicinity Energy. Due to this interconnected configuration and the proprietary operational data involved, the government identifies Vicinity Energy as the sole source capable of ensuring the reliable operation of the system without risking the broader distribution network. The scope of work requires a two-person crew to provide eight hours of service every two weeks, totaling 416 labor hours per year. Key responsibilities include steam trap surveys, cleaning pressure-reducing valves, inspecting heat exchangers, and ensuring proper water chemistry and meter operation. The contractor must supply all necessary parts meeting original manufacturer specifications and provide emergency call-back services with a technician on-site within five hours of notification. The anticipated period of performance is one year from the award date, with the possibility of option-year extensions. Interested vendors may submit capability statements to Contract Specialist Patricia Thai by 11:00 AM EST on November 10, 2026, referencing announcement number 36C24527Q0048. These submissions will be used solely to determine if the procurement will be conducted on a competitive basis. All work will be performed at the Baltimore VAMC, adhering to strict VA security, safety, and infection control requirements.
Facilities Support Services

POSTED

1 day ago

DEADLINE

in 12 days
View Details
NAICS: 423440
New
Federal
J072--JR/BP POTS AND PANS ROOM | WASHINGTON DC VAMC
Solicitation # 36C24527Q0043
The Department of Veterans Affairs is seeking a contractor for the emergency procurement, delivery, and factory assembly of commercial-grade kitchen equipment for the Nutrition and Food Services Pot and Pan Washing Room at the Washington DC VA Medical Center. This firm-fixed-price acquisition is driven by critical infection control and physical environment deficiencies identified during a June 2026 Joint Commission survey. The required equipment includes a custom Aerowerks two-compartment sink system with a drainboard, a Salvajor food waste disposer, and a Hobart TurboWash II pot scrubber. All equipment must be NSF listed, commercial grade, and compliant with Joint Commission, CMS Conditions of Participation, and FDA Food Code standards. The contractor is responsible for freight, uncrating, and delivery to the facility within 60 calendar days of award. A qualified Aerowerks technician must perform the on-site assembly within 14 days of delivery to preserve the manufacturer warranty. Strict safety and cleanliness protocols are in effect, including the requirement for hot work permits for welding and the immediate removal of all packaging and metal debris to prevent food service contamination. Payment will be issued via a single electronic invoice on a Net 30 basis following the COR's written acceptance of the installed and inspected equipment.
Other Commercial Equipment Merchant Wholesalers

POSTED

3 days ago

DEADLINE

in 6 days
View Details
NAICS: 238210
New
Federal
J061--INTENT TO SOLE SOURCE AWARD TO EATON CORP - BASE YEAR MAINTENANCE AND SERVICE CONTRACT FOR 8 UPS HERSHEL WOODY WILLIAMS VAMC
Solicitation # 36C24527Q0046
The Department of Veterans Affairs intends to award an open market sole source contract to Eaton Corporation (UEI: NP3NSFVMNUM3) for a one-year service and preventative maintenance agreement. The contract covers eight specific Eaton UPS systems located at the Hershel Woody Williams VA Medical Center in Huntington, West Virginia. The scope of work includes a Flex Plan consisting of two UPS and two battery preventive maintenance checks for all eight systems. This procurement is classified under NAICS code 238210 for Electrical Contractors and Other Wiring Installation Contractors and PSC J061 for the maintenance and repair of electric wire and power distribution equipment. The government is pursuing a sole source award because Eaton Corporation is the original equipment manufacturer and the only authorized provider of the proprietary service software, repair documentation, and materials required for 3-phase Eaton UPS products. As an ISO9001 certified supplier, Eaton does not certify or support third-party providers for these specific products. This notice is published in accordance with FAR 5.101(a) and FAR 12.102. Interested vendors may submit capability statements to Contracting Officer William Pratt by November 12, 2026, at 10:00 AM ET, referencing announcement number 36C24527Q0046 to determine if the requirement will be competed.
Electrical Contractors and Other Wiring Installation Contractors

POSTED

3 days ago

DEADLINE

in 14 days
View Details

Earlier notices in this NAICS code

Posted before this notice, open and closed

Find Active Opportunities Like This

Get AI-powered intelligence on the opportunities still open

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS