J - The VAMC, 1310 24th Avenue South, Nashville, TN site has a need to provide services of Deltanet maintenance for the HONEYWELL BUILDING MANAGEMENT AND CONTROL SYSTEMS LOCATION: BUILDING #1 TECHNICAL EXHIBIT #1 EQUIPMENT DESCRIPITION: QUANTITY Controller, Model R7044-D 7 Controller, Model R7044-E 11 Personal computers, monitors, 4 keyboard, mouse located in: M&O Supervisor Office (E08) Utility Systems Supervisor Office (E06) Boiler Plant Control Room (E25F) Honeywell Control Room (D-72) Multi-channel Gateway, Model W7053 1 Honeywell EBI Poweredge 1900 Server 1 Room D-72 Air/Water flow switches, AFS 64 Differential pressure transducer 19 Model DWY0116470100 Temp. sensor, series T7000 52 Humidity sensor Model H7506 32 E/P transducer Model RP7517 45 Digital outputs/start stop relay S/S 76 Microcel controller model R7516 35 Space sensor model T7515 35 Portable Operator Terminal CCT2190 1 Robinson Halpern DP transducer 5 Data Industrial Turbon flow meter 22655 6 Wattage transducer W972 1 Graphic Central Remote terminal S1002 1 TECHNICAL EXHIBIT #2 961-24031, Bone Marrow (AHU #37 and #38) 1-New R7044E Controller 8-R7515A4004 Micro cels 4-RP7515B3008 Micro cels 961-24035, TB Infectious Phase I Added points to existing R7044 Controller 14 10-R7515A1059 Micro Cels 961-25008, Cath Lab Expansion Added points to existing R7044 Controller 29 961-25027, Radiology Added points to existing R7044 Controller 29 961-25029, TB Infectious Phase 2 Added points to existing R7044s Controllers 12,23,22,20 and 9 961-26013, CT Scanner Room Added points to existing R7044 Controller NO NUMBER 961-26020, Cath Lab 2 1-New R7044D 2-R7515B1049 961-26024, Dietetics 1 New R7044E - Controller 961-26025, Patient Upgrade Ward 4A/B (4 North – AHU #40) 2-New R7044E Controllers 16-RP7515B3006 Micro cells 961-27XXX, Patient Upgrade Ward 3A/B (AHU #41) 1-New R7044D Controller 8-R7515B3016 Micro Cells Privacy Upgrade Ward 2A/B, one new R7044E controller Tertiary Pump and related control components located in Fan room 3 and Fan room 15 added to existing R7044E panel Tower #3 – Analog points 4, added to existing R7044E controller 4, loops 2, digital points 10 AHU 48 and 49 added points to controller 11 (electrical distribution project) TECHNICAL EXHIBIT #3 SOFTWARE LIST: QUANTITY Microsoft Windows XP 4 M&O Supervisor Office Utility Systems Supervisor Office Boiler Plant Control Room Honeywell Control Room (D-72) Microcel Controller Operating Sys. R7516 1 Location – D72 Limited edition Maintenance Maximo LE500 1 Location - D72 Manager Software DeltaNet Excel Plus Portable S503 1 Location – D72Programmers Terminal Software DeltaNet Customer Program S997 1 Location - D72 C-NAP Network Interface S982 1 Location - D72 Operating System Software for S982 1 the R7044 Excel Plus Controller, Location D72 Honeywell EBI Software (Installed) 1 M&O Supervisor Office Utility Systems Supervisor Office Boiler Plant Control Room Honeywell Control Room (D-72) Honeywell EBI Software (physical software) Honeywell Control Room (D-72) DeltaNet Coprocessor Software S979 1 Location - D72 DeltaNet Communication Board S980 software 1 Location – Integrated, XBS-1 version 2.3, Location D-72 DGC Delta Upgrade Y2K patch 4 Version 16.4.1, Location BD153B Excel Bldg. Supervisor Integrated Protection Disk, Location BD153B ADDED IN FY-2006 Equipment Description in ACRE Wing Quantity Open Link Controller Q9200 used to communicate 1 With York Chiller Controller R7044 and sensors 1 Used to control AHU-50 Micro-cel controllers R7515 used for control of fan coil units 14 Installed as part of electrical upgrade project Added in FY 2010 – All points AHU 51 and 52 in Fan room 15 and areas served York Air Cooled Roof top chiller AHU 53 Roof outside Fan room 3 and area served Dialysis AHU 9 AHU 26 Acre Bldg Environmental Controllers New AHU 5 Honeywell CP-5050 BACNET Network Device LONWorks IP Server Network Device Lynx Sysco Network Device SD2008 Removal of AHU 1 and old AHU 5 (contract should reflect the removal of two units in cost and time) The new Honeywell panels in acre bldg – (these replaced the old Honeywell panels so there should be no change in the cost or maintenance of the panels) Contractor to provide ongoing training of EBI system annually to VAMC employees. Training can be web-based or in class training courses conducted by Honeywell Subject Matter Experts (SME’s). These sessions detail important product and system topics that operators and administrators will find essential to keep up to date with current EBI system developments and beneficial to the facilities management. Up to eight (8) hours of local training at site by Honeywell Technician. Training includes enrollment, materials and attendance. Travel and travel related expenses not included. Contractor to provide software version upgrades replaced with current EBI software technology releases. Scope of work includes: back up of software at each server and workstation, installation of new software at each server and workstation, programming of database information in to new software, testing and training of new software to users. EBI Points Expansion – Upgrade package of 5,000 additional points due to current system capacity for a total of 10,000 EBI points. Scope of work includes copying and back up of operating database, update all stations, external interfaces, SUSI Software, update BacNet interface, software license, and programming, testing and training for users. Contractor to provide hardware upgrades as needed (current technology is every three (3) years. Scope of work includes: upgrade of systems hardware to like system with new technology, back up of current software programs, installation of existing software version on to new hardware, disposal of hardware, testing and training to users. Equipment to be upgraded: - Computers (1 server, 4 workstations) - Printers (2) - Monitors (4) - Mouse (4) Period of one base year with one one-year option period. Anticipated procurement issued 7/30/2010. Evaluation will be past performance and price.