This Combined Synopsis/Solicitation opportunity from Department Of Veterans Affairs was posted on September 16, 2026. The submission period has ended. Browse the details below for market research, or find similar active opportunities.
J030--Generator-ATS Maintenance (VA-27-00002745)
Contract Overview
Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.
Active Opportunities Like This One
AI Contract Overview
Solicitation 36S79726Q0006 is a Service-Disabled Veteran-Owned Small Business set-aside for the preventive maintenance, testing, service, and repair of power systems at the Department of Veterans Affairs Service and Distribution Center, Building 37, in Hines, Illinois. The scope of work includes monthly maintenance for five diesel-powered generators and their associated automatic transfer switches, annual load bank testing, and quarterly inspections and cleaning of two on-site transformers. A critical requirement involves the Consolidated Mail Order Pharmacy generators, which must be serviced on the second Tuesday of each month between 4:00 AM and 7:00 AM to avoid production delays. The contract also mandates annual infrared scanning of transformer lugs and automatic transfer switches while energized to identify faults before scheduled de-energized maintenance. The contract structure consists of a base period from February 1, 2027, through January 31, 2028, with four subsequent option years, for a total potential duration of five years. Pricing includes fixed costs for monthly, quarterly, and annual services, alongside a not-to-exceed funding amount of 50,000 dollars per year for unscheduled repairs. The contractor is responsible for providing routine consumables such as filters and fluids, while major components like batteries and alternators are handled via the unscheduled repairs CLIN. Technicians must have at least five years of experience and be OEM-trained where required. All work must adhere to NFPA 110, NFPA 70/70E, and OSHA 1910 standards, with the VA furnishing all diesel fuel.
General Info
Place of Performance
1st Ave., One Block N of 22nd Bldg 37, Hines, IL, 60141Set-Aside
Timeline
Submission Closed
Organization & Contact Information
Full Description
Can you provide a Document with each Back-up Generator Model # s &Serial # s? This is Attachment A of the package
Please Confirm the Voltage of the Generators? 480 and 240
Regarding Contractor Provided Consumables, many of the items listed are typically repairs quoted and approved before work proceeds on this and some parts(hoses and belts). As an outside vendor there is no way to effectively build this into your maintenance plan to guarantee effective cost for both the vendor and for Edward Hines VA. We request this section is altered to allow for these costs to be sectioned out for repairs and for one annual service to replace filters and oil. See Attachment B.
How many Generators have Diesel Engines? All of them
Are there any Generators with difficulty accessing (Roof, Parking Garage, Basement)? If so, which units are they? NO
Are your Generators within 50 ft of the Entry Door, where our truck will be parked? Yes
Are the Annual Load Tests performed with your Minor B-PMs? No
Can I get the age of each equipment if possible? See Attachment A
Please clarify the Unscheduled Repair CLIN amount. Is the stated $50,000 intended to mean $50,000 per contract year? This is just a funding item for me to populate an unscheduled maintenance clin for me to address items the break.
Where should emergency travel and labor be priced? All previous contracts has local labor. Never had this issue. Build it in your quote.
Will VA furnish diesel consumed during inspections? VA furnishes Fuel for the generators Period.
Can you provide any previous maintenance reports, emergency calls, major repairs, etc.? After Award.
Consumables Attachment Section 2.1 states Replace PM Consumables as required and references Attachment 1, while the solicitation package includes Generator Consumables Attachment B. Please confirm that Attachment B is the document intended by the reference to Attachment 1, and that the consumables identified in Attachment B are to be furnished and replaced by the contractor as required during preventive maintenance and included within the applicable PM CLIN pricing. Consumables are outlined in Attachment B.
Work Hours / Load Bank Testing Section 4.3 identifies the monthly PM for the two 600 kW generators and one 500 kW generator as occurring on the second Tuesday of each month from 4:00 AM to 7:00 AM, while the 1250 kW and 750 kW generators may be serviced during normal business hours. Please confirm whether the annual load-bank testing, ATS maintenance, sampling, and other annual maintenance activities may also be performed during normal business hours unless otherwise coordinated with the COR.
The 600 s, and 500 are backing up a critical production line that is old and has issues during power transfers. We require them and their associated equipment to be cycled or maintained prior to that department s workday start, so they can start the production line on time with no delay. This department is the Consolidated Mail Order Pharmacy (CMOP). All the generator maintenance is to be performed on the second Tuesday of each month, we need the CMOP Generators started and done first.
Transformer Annual Inspection and IR Scan The scope includes quarterly energized transformer inspections as well as an annual inspection that includes additional maintenance activities and an IR scan. The pricing schedule only provides a quarterly transformer CLIN with a quantity of four. Please confirm whether the annual transformer inspection and IR scan are to be included within the pricing for the four quarterly inspections, with one quarterly service incorporating the annual work, or if the annual service is to be priced separately.
Please confirm the intended operating condition for the annual IR scan, as it appears under the annual de-energized inspection section.
Annual Transformer and ATS IR Scanning Procedure The annual infrared (IR) scan of transformer lugs and automatic transfer switches (ATSs) is to be completed while the equipment is energized, prior to any deenergizing procedures. This approach allows for the identification of potential faults under operating conditions, ensuring that any issues are detected before maintenance begins. Once the IR scan is performed, any necessary repairs should be made during the scheduled deenergized maintenance period. This ensures that faults identified during the scan can be addressed safely while the equipment is not under load. The IR scan should occur once each year and, whenever possible, should be scheduled close to the time of the annual deenergized maintenance. This coordination facilitates efficient fault resolution and minimizes downtime. In the event of an emergent issue identified during the scan, immediate corrective action will be taken to address the problem as soon as possible, regardless of the scheduled maintenance cycle.
More opportunities from Department Of Veterans Affairs → Nac Facility Purchasing Support (36S797)
Same awarding agency
Find Active Opportunities Like This
Get AI-powered intelligence on the opportunities still open
Every page of the solicitation package shredded into a compliance breakdown
AI-powered matching based on your capabilities and past performance
Competitor and incumbent history on the requirement
Automated alerts on amendments, Q&A deadlines, and award
Join 750+ contractors already using CLEATUS