J030--Generator Maintenance-581 Huntington WV

Closed
36C24521Q0393Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

Active Opportunities Like This One

NAICS: 811310
New
Kubota M8200 Clutch Replacement
Solicitation # kubota-m8200-clutch-replacement
Management & Training Corporation (MTC) is soliciting bids for the clutch replacement of a Kubota M8200 tractor with front wheel assist, no cab or loader, located at the Earle C. Clements Job Corps Center in Morganfield, Kentucky. The scope of work requires the contractor to provide all transportation, labor, supervision, tools, and new manufacturer-specified parts to diagnose and repair the clutch assembly and power take-off (PTO) system. Key technical requirements include disassembling tractor components, replacing friction discs, bearings, oil seals, and O-rings, resurfacing the flywheel, and replacing hydraulic pipes and filters as necessary. The project is complete once the Facility Maintenance Department verifies proper clutch engagement and PTO operation under load. This is a small business set-aside opportunity under NAICS code 811310, open to various SBA-certified categories including VOSB, SDVOSB, WOSB, and HUBZone businesses. Proposals must be submitted via email to Angie Mahoney by November 3, 2026, and must include a lump sum bid sheet, a completed supplier packet with a W-9 and self-certification form, and proof of insurance. Award will be based on best value, considering the contractor's qualifications, experience, and the itemized cost breakdown. The contract is subject to Federal Acquisition Regulation (FAR) clauses regarding the Buy American Act, combating trafficking in persons, and Service Contract Labor Standards per Wage Determination No. 2015-4687 Revision 31 for Kentucky.
Earle C. Clements Job Corps Center

POSTED

about 8 hours ago

DEADLINE

in 5 days
NAICS: 811310
New
SLED
**Certified SB/DVBE Only** IFPQ Boiler Inspection, Maintenance, Repair, Testing, and Reporting in Los Angeles County
Solicitation # 07A6539
The California Department of Transportation (Caltrans) is soliciting price quotes for an Invitation for Price Quote (IFPQ 07A6539) to provide comprehensive boiler inspection, maintenance, repair, testing, and reporting services at the District 7 Office facility in Los Angeles, California. The scope of work includes annual and quarterly preventative maintenance for three Unilux water tube boilers and six boiler pumps, ensuring compliance with manufacturer standards, ASME Code, OSHA requirements, and South Coast Air Quality Management District standards. This is a set-aside solicitation exclusively for certified Small Business (SB), Microbusiness (MB), or Disabled Veteran Business Enterprise (DVBE) entities. The contract will be awarded to the responsible bidder offering the lowest price quote who meets all specifications. Key operational requirements include a 48-hour response time for routine service requests and a strict prohibition on subcontracting any portion of the work. The contractor must adhere to State General Prevailing Wage Rates for Los Angeles County and provide a payment bond for any service request exceeding 25,000 dollars. Required submission documents include a Price Quote Proposal, Bidder Certification Sheet, Non-Collusion Declaration, and certifications for California Civil Rights Laws and the Darfur Contracting Act. Invoicing is conducted monthly in arrears and must be accompanied by certified payroll records and DVBE utilization reports. The agreement is subject to a budget contingency clause, meaning it is enforceable only if sufficient funds are provided by the California State Legislature or the United States Government.
California Department of Transportation

POSTED

about 9 hours ago

DEADLINE

in 15 days
NAICS: 811310
New
SLED
RFP 07-135 Roseville Electric Utility – Air Compressor Maintenance
Solicitation # 07-135
The City of Roseville is soliciting proposals under RFP 07-135 for a consultant to provide comprehensive scheduled preventive and corrective maintenance for air compressors and auxiliary systems, including Ingersoll Rand equipment. The services will be performed at the Roseville Energy Park and Sunset Energy Center in California. The selected consultant will be responsible for providing all necessary labor, technical expertise, specialized tooling, and materials. This is a prevailing wage project with an initial contract duration of five years, estimated to commence in April or May. Proposals must be submitted by December 16, 2026, via email to the City Clerk or through physical delivery in a sealed container with the required Attachment H label. The award will be based on a formal evaluation panel process considering the firm's experience and qualifications (25 points), the proposed project plan (35 points), and cost (40 points), with potential interviews for top candidates. Requirements for the successful bidder include obtaining a City of Roseville business license, providing 100% faithful performance and labor and materials bonds, and maintaining specific insurance policies. Consultants must also disclose any conflicts of interest and adhere to the Levine Act regarding political contributions.
City of Roseville

POSTED

about 14 hours ago

DEADLINE

in about 2 months

General Info

NAICS

811310 - Commercial and Industrial Machinery and Equipment (except Automotive and Electronic) Repair and Maintenance

Place of Performance

Huntington VA MC 1540 Spring Valley Rd., Huntington, MD, 25704

Set-Aside

NONE

Documents

1

36C24521Q0393.docx

DOCX

AI Contract Breakdown

Uniform Contract Format

Contract not broken down yet

CLEATUS splits the solicitation into Uniform Contract Format (UCF) sections: scope, pricing, deliverables, and evaluation criteria.

Timeline

PhaseClosed
Posted

Sources Sought

Response Deadline

Deadline has passed

Submission Closed

Find active opportunities like this

Get full access to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyDepartment Of Veterans Affairs → 245-NETWORK Contract Office 5 (36C245)
Contacts1 person available
OfficeLINTHICUM, MD, 21090, USA
Office AddressLINTHICUM, MD, 21090, USA

Full Description

Show more
This is a request for information/sources sought notice to identify sources that have the resources and capabilities to provide Generator Maintenance services for the Veterans Health Administration Huntington VA Medical Center. Interested & Capable Responses NCO 5 is seeking responses from businesses that are interested in this procurement and consider themselves to have the resources and capabilities necessary to provide the services described in SOW. Please respond with your: 1. Business name, business type, socio-economic status (e.g., Veteran-Owned, Woman- Owned, Disadvantaged Small Business, 8(a), etc.), D&B number, and person of contact (including telephone number & email address). 2. GSA contract number, if your company has one, that includes the labor CLINs necessary for the performance of the work specified above. 3. Capability statement and summary of relevant experience performing these types of services for VHA and other healthcare entities. 4. Ballpark cost estimate what VHA could expect to pay your company to perform the work described above. Responses must be submitted by 4:00 PM (EST) April 23, 2021. Responses to the information requested above may be submitted via email to contact@example.gov. This request for information/sources sought notice is for planning purposes ONLY. The results of this market research will assist in the development of (1) the requirement, and (2) the acquisition strategy (e.g., small business set-aside, full and open competition, etc.). VA assumes no responsibility for any costs incurred associated with the preparation of responses submitted because of this notice. B.2 STATEMENT OF WORK PART A GENERAL INFORMATION A.1 INTRODUCTION The Hershel Woody Williams VAMC located at 1540 Spring Valley Drive, Huntington WV, 25704 has a requirement to have 3 emergency backup generators serviced. A.2 BACKGROUND The VAMC has 3 large Emergency Backup Generators, which start automatically during a power outage. All 3 Generators require Preventive Maintenance, Checks and Services. (ie, changing the oil, new fuel filter, new oil filters, New Air Filters, ect). A.3 SCOPE OF WORK Vendor will provide all parts, labor, equipment, material, supplies (Oil, Oil Filter, Fuel Filter, Air Filter, ect.) and supervision to service and conduct Preventive Maintenance on 3 Emergency Backup Generators per the Statement of Work listed below. The entire Checklist found in Part B.2 must be completed on each Generator to include the 4 Major tasks listed below: (a) Change Oil (b) Change Oil Filter (c) Change Fuel Filter (d) Change Air Filter The service company is to be aware that the list of generators found in Part B.1 may change from option year to option year. Services are to be provided starting in May of 2021 through May of 2022, with up to 3 option year renewals. STATEMENT OF WORK PART B WORK REQUIREMENTS B.1 The following is a list of the generators that are required to be serviced: B.2 Task to be completed for each generator. The following Preventive Maintenance, Checks and Services will be conducted as appropriate/required for each specific generator: Check condition & tension of all belts. Adjust as necessary. Check super/turbocharger for leaks & wear. (if applicable) Visually check lube oil condition & level. Visually check for oil leaks. Visually check coolant condition & level. Record anti-freeze protection level. Record coolant dca protection level. Visually check for coolant leaks. Visually check operation of coolant heater. Visually check condition of coolant hoses. Visually check condition & operation of remote radiator. (if applicable) Pressure test radiator cap. Visually check exhaust system condition & for leaks. Change Air Filter. Visually check hoses, clamps, and air restriction indicator. Change Motor Oil. Change Motor Oil Filter. Visually check air & vent tube connections. Clean and inspect crankcase breather. Visually check fuel lines & connections. Visually check day tank fuel level. Visually check for fuel leaks. Check transfer or day tank pump. Change fuel filter(s) Clean fuel bowl. (if applicable) Visually inspect ac/dc brushes & commutator. (if applicable) Visually inspect commutator. (if applicable) Visually inspect collector ring. (if applicable) Visually inspect electrical connections. Visually check battery connections & clean if needed. Visually check battery condition & solution level. Check starting system operation. Record cranking voltage. Note overall condition of battery system. Check condition of charger and record battery charger amps and volts. Run & check for proper lube oil pressure, water temp, coolant temp, oil temp, alternator charge rate, voltage, and frequency. Run & check for normal operation & leaks. Check for vibration. Visually check operation of louvers. Check for proper governor operation. Record all gauge and meter readings. Check output of generator ac voltage. (automatic transfer switch) Check condition of voltage sensors. (automatic transfer switch) Check for proper adjustment of timers. (automatic transfer switch) Check for proper adjustment of start relay. (automatic transfer switch) Visually check exerciser clock for proper operation. A detailed list of materials/parts needed to conduct Preventive Maintenance for each generator will be provided by the Vendor to the VAMC. This list will include part numbers for all items on each generator such as Oil, Oil Filter, Fuel Filter, Air Filter, ect. On several generators the VAMC will hook up a portable generator before the servicing begins, to assure the continuity of electricity. This may delay starting the servicing by a short period of time, though we will pre-position the portable generator and we use quick disconnects. All service adjustments will be made in accordance with manufacturer's specifications using required tools and procedures. Vendor shall be responsible for cleaning of the work area and equipment upon completion of work. All diesel engines shall be wiped free of oil and grease. The diesel room floor area shall be swept clean. All accumulated rubbish shall be removed daily. All fuel oil, lubrication, and any other material substance creating an unsafe operating area shall be removed daily. The contractor shall be responsible for the proper disposal of all hazardous materials as a result of this contract. All used oil or other petroleum products shall be removed by the contractor upon completion of work. STATEMENT OF WORK PART C SUPPORTING INFORMATION C.1 Place of Performance The Hershel Woody Williams VAMC located at 1540 Spring Valley Drive, Huntington WV 25704. C.2 Period of Performance The Contractor shall perform all work during normal business hours, (unless other times are stipulated by the Contracting Officer s Representative (COR) with the approval of the Contracting Officer. The contractor shall perform maintenance on the generators annually every May or per manufacture specifications. C.3 Special Considerations C.3.1 Contractor Furnished Materials All labor, materials, equipment to perform the job. When furnish , provide , install , or similar term is used it shall mean a complete installation, ready for use. The vendor shall supply all parts, equipment, material, and labor to conduct work as listed in the Statement of Work above. The work will include all items as described in the Scope of Work listed above. C.3.2 Qualifications of Key Personnel Contractor s employees should be knowledgeable of standards associated with this type work. C.3.3 Supervision/Communications. At all times during the performance, the Contractor s Superintendent (if applicable) shall be available by cellular phone. Prior to beginning any work, the Contractor shall supply the COR with the telephone number for the Superintendent. The Contractor s Competent Person that meets OSHA training guidelines, can make decisions and acting on behalf of the Contractor shall be physically located on site at all times during performance of the contract. If the Contractor s Competent Person is absent from the job site for an extended period, the COR may send all Contractor/sub-contractor employees off the job. C.3.4 Security Requirements: Contractor shall identify which employees will be working under the awarded contract. Contractor personnel shall include employees, sub-contractors, subcontractor employees, suppliers and delivery personnel entering the Medical Center. This does not apply to suppliers and delivery personnel making deliveries to the VA warehouse dock only. Those employees shall bring photo ID to obtain a VA Contractor identification badge that shall always be worn above the belt while on Medical Center property. Contractor s employees shall return all I.D. badges to designated personnel at time designated in the task order. C.3.5 The Contracting Officer s Representative (COR) is responsible for the inspection of the work called for in this job. The Contracting Officer s Representative will be identified in the task order by name, telephone number and location. Inspections made by the COR are for the sole benefit of the Government and do not relieve the Contractor of any quality control responsibilities. C.3.6 The Safety Manger is responsible for safety inspections of all contract operations. The Safety Manager will be identified in the task order by name, phone number and location. C.3.7 Smoking Policy. The Contractor shall not allow smoking on medical center property. C.3.8 Parking/Traffic Regulations. The Contractor shall not park on grassy areas unless approved by the COR and the Contractor agrees to restore areas back to VA standards. Drivers should be particularly concerned with pedestrian traffic. Yield to pedestrians in crosswalks. Posted speed limits and all other traffic controls are always to be observed by operators. Seat belt use is mandatory on the VA grounds.

More opportunities from Department Of Veterans Affairs → 245-NETWORK Contract Office 5 (36C245)

Same awarding agency

NAICS: 541330
New
Federal
C1DA--VISN 1 - INDEFINITE DELIVERY INDEFINITE QUANTITY ARCHITECT CONTRACT (Legacy VISN 5)
Solicitation # 36C24526R0107
The Department of Veterans Affairs, Network Contracting Office 5, is seeking an Indefinite Delivery Indefinite Quantity Architect and Engineering contract to provide ongoing engineering services for medical facilities and community based clinics within Legacy VISN 5, covering Maryland, West Virginia, and Washington D.C. This procurement is a total set-aside for Service-Disabled Veteran-Owned Small Businesses under NAICS 541330, with a small business size standard of 25.5 million dollars. The overall contract value is not to exceed 450 million dollars over a ten year period. Work will be executed through firm fixed price task orders competed among awardees, with individual task order values ranging from a minimum of 2,500 dollars to a maximum of 2 million dollars. The anticipated solicitation date has been revised to late December 2026 or early January 2027, with a current response deadline listed as January 8, 2027. Prospective offerors must be registered in the System for Award Management and verified in the VetBiz Registry to be eligible for award. Interested parties are explicitly instructed not to submit SF330s during this pre-solicitation phase, as the current notices are for informational purposes only. All inquiries regarding this requirement should be directed via email to the contracting officer, Liana J Holland.
Engineering Services

POSTED

about 18 hours ago

DEADLINE

in 2 months
View Details
NAICS: 513210
New
Federal
7A21--CVI 42 Evolve Tier 1 License Subscription
Solicitation # 36C24527Q0045
The Department of Veterans Affairs, through the VA Maryland Health Care System, is soliciting a contract for CVI Evolve Tier 1 software licenses and support for the Cardiology department at the Washington DC VA Medical Center. The contractor is responsible for providing all necessary software licenses, parts, materials, labor, and training required to implement, maintain, and upgrade the system. The scope specifically includes two seats of the CVI 42 Evolve Tier 1 Subscription, covering advanced reporting and specialized modules such as 4D Flow, Aortic Valve, Cardiac MR, Circle Plaque, Core CT, Mitral Valve, Quantitative Perfusion, and Strain. The contract is structured with a base year running from January 1, 2027, to December 31, 2027, and four subsequent one-year option periods, extending the total potential duration to five years through December 31, 2031. Award will be granted to the responsible offeror whose proposal is most advantageous to the government, considering price and technical factors. Key requirements for offerors include providing a manufacturer's letter of authorization, detailed OEM implementation and training plans, and justification of compatibility with existing cardiovascular equipment. Administrative requirements specify that payments will be made in arrears upon receipt of a properly prepared invoice containing the contract and purchase order numbers, as well as the equipment serial numbers and model names. The contractor must comply with Buy American certifications, OSHA safety regulations, and Controlled Unclassified Information (CUI) protocols. Performance will take place at the Washington DC VA Medical Center, with the government retaining the right to inspect and test all services and supplies prior to acceptance.
Software Publishers

POSTED

about 18 hours ago

DEADLINE

in 6 days
View Details
NAICS: 561210
New
Federal
J044--NOTICE OF INTENT TO SOLE SOURCE Baltimore VAMC Steam System Preventive Maintenance from Vicinity Energy Baltimore Corporation
Solicitation # 36C24527Q0048
The Department of Veterans Affairs is issuing a Notice of Intent to Sole Source for an open market award to Vicinity Energy Baltimore Corporation to provide annual steam system preventive maintenance at the Baltimore VA Medical Center. This requirement, classified under NAICS code 561210 and PSC J044, is driven by the fact that the facility's steam equipment is directly connected to the district steam distribution system owned and operated by Vicinity Energy. Due to this interconnected configuration and the proprietary operational data involved, the government identifies Vicinity Energy as the sole source capable of ensuring the reliable operation of the system without risking the broader distribution network. The scope of work requires a two-person crew to provide eight hours of service every two weeks, totaling 416 labor hours per year. Key responsibilities include steam trap surveys, cleaning pressure-reducing valves, inspecting heat exchangers, and ensuring proper water chemistry and meter operation. The contractor must supply all necessary parts meeting original manufacturer specifications and provide emergency call-back services with a technician on-site within five hours of notification. The anticipated period of performance is one year from the award date, with the possibility of option-year extensions. Interested vendors may submit capability statements to Contract Specialist Patricia Thai by 11:00 AM EST on November 10, 2026, referencing announcement number 36C24527Q0048. These submissions will be used solely to determine if the procurement will be conducted on a competitive basis. All work will be performed at the Baltimore VAMC, adhering to strict VA security, safety, and infection control requirements.
Facilities Support Services

POSTED

1 day ago

DEADLINE

in 11 days
View Details

Earlier notices in this NAICS code

Posted before this notice, open and closed

Find Active Opportunities Like This

Get AI-powered intelligence on the opportunities still open

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS