Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, November 11 at 2:00 PM ET

Register Free →

This Sources Sought opportunity from Department Of Veterans Affairs was posted on February 22, 2022. The submission period has ended. Browse the details below for market research, or find similar active opportunities.

J039--Elevator Maintenance Fargo VAMC Small Business Set-Aside

Closed
36C26322Q0307Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

Active Opportunities Like This One

NAICS: 238290
New
Centennial JCC Panic Hardware Services (Electrical Room Egress Doors)
Solicitation # Panic Hardware (Electrical Room Egress Doors)
Management & Training Corporation (MTC) is soliciting bids for the installation of commercial-grade panic hardware on electrical room egress doors at the Centennial Job Corps Center in Nampa, Idaho. The scope of work includes conducting site surveys to verify door dimensions and fire ratings, procuring Grade I heavy-duty panic bars, exterior trim, rim cylinders, strikes, and door closers, and performing installation and testing. All work must adhere to NEC 2023 Article 110.26(C)(3), NFPA 101 Life Safety Code, and ADA standards. To ensure fail-safe operation, contractors must perform at least 10 consecutive cycle tests on all installed hardware. This is a fee-for-service subcontracting opportunity open to small businesses, including certified VOSB, SDVOSB, WOSB, and HUBZone entities under NAICS code 238290. Bidders must be licensed in the State of Idaho and provide three references for similar projects. Required submission documents include a completed bid sheet with lump sum and individual deficiency pricing, a W-9, a self-certification form, and acceptance of terms and conditions. All bids must be submitted via email to Sandra Clore by December 1, 2026, at 3:00pm MST. The contract is subject to various federal regulations, including the Davis-Bacon Act for prevailing wage rates and fringe benefits, as well as FAR clauses regarding Buy American preferences and combating trafficking in persons. Contractors are required to comply with DOL records management, mandatory training, and privacy breach notification requirements. Payment will be issued upon the submission of invoices for materials and services that have been delivered and accepted by MTC. Final inspection and acceptance will occur at the MTC designated point of delivery.
Management & Training Corporation/Centennial Job Corps Center

POSTED

about 1 hour ago

DEADLINE

in about 1 month
NAICS: 238290
New
SLED
Kitchen Elevator Upgrade and Repair Service - NHSP-M
Solicitation # RFP NHDOC 2027-07
The New Hampshire Department of Corrections is soliciting proposals for a firm fixed price or not-to-exceed contract to provide comprehensive upgrades and repairs for a 1985 Dover Corporation passenger elevator at the New Hampshire State Prison for Men. The elevator, which serves two floors of the kitchen and has a 4,000-pound capacity, requires a new power unit including the motor, hydraulic valve, pump, oil reservoir, and muffler, as well as the installation of four security key switches and eight keys. All work must be performed by New Hampshire licensed professionals and comply with all local, state, and federal elevator codes, with final safety test results submitted to the New Hampshire Department of Labor. The project is expected to start in January, with a final completion deadline of June 30, 2027. Proposals are due by 2:00 PM EST on November 13, 2026, and must be submitted as separate sealed technical and cost proposals. Evaluation is based on a combined score of the technical proposal, which focuses on organizational experience, correctional facility expertise, and approach, and the cost proposal. Award selection may involve a Best and Final Offer process. Selected vendors must maintain significant insurance coverages, including commercial general liability of at least 1 million dollars per occurrence, and adhere to strict correctional facility security protocols, including tool inventories and compliance with PPD 371. Payment will be issued within 30 days of receiving approved monthly itemized invoices.
Department Of Corrections

POSTED

about 4 hours ago

DEADLINE

in 15 days
NAICS: 238290
New
Federal
J039--561A4-25-500 Elevator Repair Building 6 and 53
Solicitation # 36C24226R0097
Solicitation 36C24226R0097 is a Request for Proposal issued by the Department of Veterans Affairs for the emergency upgrade and modernization of four elevators at the VA New Jersey Healthcare System Lyons Campus, specifically targeting one passenger elevator in Building 6 and one service and two passenger elevators in Building 53. The scope of work requires the contractor to provide all labor, materials, and supervision to install non-proprietary microprocessor-based control systems, new geared machines, car operating panels with braille markings, hall fixtures at ADA compliant heights, and complete shaft wiring. All work must adhere to current safety codes, including fire recall features and door lock monitoring, and comply with the Davis-Bacon Act for prevailing wage rates. This procurement is a Service-Disabled Veteran-Owned Small Business set-aside under NAICS code 238290. To be eligible, the prime contractor must be a licensed elevator maintenance company with a full-time mechanic on staff and a clean safety record, certifying no more than three serious, one repeat, or one willful OSHA or EPA violation in the last three years. Proposals are evaluated based on technical capability, past performance, and price, with a requirement to submit a current Experience Modification Rate (EMR) and certifications for the Buy American Act and limitations on subcontracting. Following several extensions to accommodate requests for information, the final deadline for proposal submission is 1:00 PM on Thursday, October 29, 2026.
242-NETWORK Contract Office 02 (36C242)

POSTED

about 8 hours ago

DEADLINE

in 22 days

General Info

NAICS

238290 - Other Building Equipment Contractors

Place of Performance

FARGO VAMC 2101 Elm St N, Fargo, ND, 58102, USA

Set-Aside

SBA

Documents

1

36C26322Q0307_Sources+Sought+%28Small+Business+Set-Aside%29.docx

DOCX

AI Contract Breakdown

Uniform Contract Format

Contract not broken down yet

CLEATUS splits the solicitation into Uniform Contract Format (UCF) sections: scope, pricing, deliverables, and evaluation criteria.

Timeline

1 update
PhaseClosed
Posted

Sources Sought

Notice updated

The notice description changed.

Response Deadline

Deadline has passed

Submission Closed

Find active opportunities like this

Get full access to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyDepartment Of Veterans Affairs → Network Contract Office 23 (36C263)
Contacts1 person available
OfficeSaint Paul, MN, 55101, USA
Office AddressSaint Paul, MN, 55101, USA
Contacts
Jeffrey BrownContracting Specialist

Full Description

Show more
Opportunities Description This is a sources sought/proof of capability solicitation looking for Small Business vendors to perform the services per the Statement of Work (SOW) for market research purposes. No awards of a contract will be made from this announcement. If you are a vendor that can complete the work described in the SOW with competitive pricing, please send your information with a description of proof of capability to: contact@example.gov on or before March 1st, 2022. *VAAR Provision, 852.219-77 VA Notice of Limitations on Subcontracting Certificate of Compliance for Services and Construction, will apply to the potential solicitation if set-aside for Veteran Owned Small Business and Serviced Disabled Veteran.* *FAR Provision 52.219-14 Limitations on Subcontracting, will apply to the potential solicitation if set-aside for Small-Business.* Statement of Work Provide Elevator/Cartlift maintenance services at the VA Medical Center, Fargo, North Dakota. Maintain and keep elevators at originally specified performance levels, providing all parts, labor and equipment necessary to fully maintain, inspect, test and repair all elevators/cartlifts in accordance with all terms, conditions, provisions, specifications and Schedule of Elevators in this Statement of Work to include preventive maintenance services. Perform emergency repair services 24 hours per day, 7 days per week including holidays. Elevator Inspections are as follows: FY2023, 2024, 2025, 2026, 2027 Bi-Annual January and July Annual April 5-Year April 2025 Schedule I - Schedule of Items - Base Year Car # Building # Type Manufacturer/Year Use Warranty Expiration 1 9 Auto/Dupx Sel M.C. Otis/2007 Passenger 3/10/2009 2 9 Auto/Dupx Sel M. C. Otis/2007 Passenger 3/10/2009 3 9 Auto/Singl Sel M.C. Otis/2008 Service 3/10/2009 Controls on 6/18/2010 4 1 Auto/Singl Sel M.C. Otis/2008 Passenger 7/9/2010 5 1 Auto/Singl Sel M. C. Otis/2008 Service 7/9/2010 6 1 Auto/Singl Sel M. C. Otis/2008 Service 7/9/2010 7 46 Auto/Dupl Sel M. C. Otis/2008 Passenger 7/9/2010 8 46 Auto/Dupx Sel M.C. Otis/2008 Passenger 7/9/2010 9 40 Hydraulic Apollo/1993 Passenger NA 10 46 Hydraulic Advance/1998 Passenger NA 11 9 Cartlift(Dirty Lift) Motion Control Engineering Carlift 2012 12 9 Cartlift (Clean Lift) Motion Control Engineering Cartlift 2012 13 52 Hydraulic Otis Passenger 12/1/2012 14 46 Hydraulic Otis Passenger 3/31/2018 Description / Specifications / Work Statement SCOPE OF WORK Contractor will provide full maintenance to include emergency call-back service and repair including regular and systematic inspection of each of the elevators listed in the Schedule of Items. The Contractor shall accomplish all work needed to troubleshoot, clean, lubricate, test, adjust, repair, dismantle, assemble to provide upkeep of the elevators with all repairs and replacements needed to maintain the elevators in accordance with ANSI A17 unless otherwise excluded in these specifications. All equipment, materials and installations shall conform to the following codes: The American National Standard Safety Code for Elevators, Dumbwaiters, Escalators and Moving Walls, ANSI A17.1-1990 or latest edition. American Standard Practice for Inspection of elevators, Inspectors Manual A17.2-1988 or latest edition. Contractor shall, at his expense, determine the nature and extent of any work or maintenance required to maintain elevators to operate at originally specified performance level and restore the elevators to satisfactory service, shall accomplish all such work required including but not limited to a thorough check of and replacement of safeties, car hatchways, accessories in pits to include lighting in the elevator pits, relays, contacts, contact leads, switches, selectors or associated parts, Including all/any items listed following inspections, except as excluded items listed under paragraph 1. (g) of this Section. Hoist and governor ropes are to be maintained under preventive maintenance standards and replaced as required. Contractor shall provide one (1) elevator mechanic to be present at safety inspections conducted by separate Inspection Contractor. Maintenance Contractor s mechanic will perform the tests required on buffers, safeties, governors, normal and final terminal stopping devices, emergency operation, emergency power operation, and door closing force. The above applies to semi-annual, annual and/or 5-year tests. Maintenance Contractor shall provide necessary weights and other accessories required during inspections. Contractor is responsible for making all repairs and adjustments that safety inspecting Contractor deems necessary for compliance with elevator codes. All said repairs and adjustments shall be accomplished within thirty (30) calendar days after receipt of written notification by the VA that such repairs and adjustments are necessary. Contractor SHALL NOT: Supply and replace incandescent or fluorescent lamps for car light fixtures; Supply and replace floor covering on elevator car platform; or clean and refinish car interiors and hoistway doors or frames; Install without purchase order authority, new attachments as may be recommended or directed by inspection firms or by Federal, State, Municipal or other Government authorities; Replace or make repairs to main line switches, circuit breakers, or fuses; Repair underground leaks of hydraulic elevators. Leaks underground shall be reported in writing to the Engineering Chief. Repairs will be accomplished by a separate contract; 2. MAINTENANCE INSPECTIONS: All passenger and service Gear or Traction type elevators shall be cleaned and inspected monthly. All passenger and service (hydraulic type) elevators shall be cleaned and inspected Quarterly. All cartlifts and dumbwaiters shall be cleaned and inspected bi-annually. The Contractor shall check in with M&R supervisor and checkout and be certified by the completion of the inspections and providing written service reports to the Engineering Service Maintenance Supervisor. A maintenance logbook shall be filled out each visit by the elevator repairman and kept in each elevator equipment room. 3. CLEANING, LUBRICATION AND ADJUSTMENT SERVICE: When and as required, in accordance with elevator manufacturer s requirements, the machines, ropes, brakes, motors, generators, controllers, relay panels, selectors, leveling devices, operating devices, switches on car and hoistway, hoistway door and car door or gate operating device, interlocks and contact guide shoes, or roller guides, guide grooves in hoistway and car door sills, hangers for all doors and car doors or gates, signal system, car safety device, governors, tension frames and sheaves in pit shall be cleaned, lubricated and adjusted. Contractor must furnish all lubricants, cleaning materials and parts as required. During shutdown of elevators for cleaning, lubrication and adjustment, signs must be posted at each floor to inform personnel that elevator is down for repairs. Contractor must coordinate with facility Engineering Service for shutdown(s) and day/time of shutdown(s). 4. CLEANING SERVICES: All parts, equipment, guide rails, sheaves and beams, counterweight frames, top of cars, bottom of platform, hatchways, pits and machine room floors shall be kept clean. Contractor shall clean, remove dirt, lint, excessive grease on or about the elevators, machine, motors, motor generator (MG) sets, controls and associated elevator equipment and accessories. Car tops and pits are to be cleaned at least each time the elevator is inspected, serviced or repaired. Pit cleaning will include removal of rubbish, debris, spillage, and drippings. Contractor shall coordinate day/time with the Engineering Officer, or his designee, for scheduled pit cleaning. Contractor shall furnish all necessary cleaning supplies, i. e., rags, vacuum cleaner, etc. Contractor shall wipe down all machinery and keep it free of dust. Oil rags will be placed in metal/sealed holding containers which shall be removed from the premises and disposed of when full. 5. LUBRICATION SERVICES: All sheave, machine, and motor bearing and hoisting ropes shall be lubricated, machine stuffing box and bearings on motor operated brakes shall be repacked and gear cases and guide lubrication shall be refilled when required. Hydraulic fluid sufficient to maintain required operation levels shall be furnished on all hydraulic elevators. 6. ADJUSTMENT SERVICES: All hoisting ropes shall be examined quarterly, and tension equalized, and report of rope condition written in every report, as specified under Paragraph 9, Report of Service. The exterior of the machinery and any other parts of equipment, subject to rust, shall always be kept properly painted and presentable. The motor windings shall be kept free of rust where roller guides are used and properly lubricated where sliding guides are used. Guide shoe rollers and gibs shall be renewed as required to ensure smooth and satisfactory operation. All electrical wiring and conductors extending to elevators and dumbwaiters from circuit breakers or mainline switches in machine rooms and from outlets in the hoistway shall be repaired and/or replaced when required. Circuit breakers or main line switches, together with fuses for same, are excluded. When/if Contractor s recommendation to replace hoisting ropes is approved, all hoisting ropes and governor ropes shall be replaced as required. 7. PARTS TO BE FURNISHED, INSTALLED OR REPAIRED: Contractor shall furnish and install or repair when as necessary, machine hydraulic pumps, motor generators, controllers and boards, selectors, gears, thrusts, windings, commutators, hydraulic pump belts and pulleys, hydraulic valve components and coils, circuits magnet frames, relays, contactors, control fuses, cams, car door and hoist way door hangers tracks and door guides, door operating devices, interlocks and contacts, car gates, safety devices, governors, push buttons, LED lights, annunciators, hall lanterns and indicators, lamp replacement in signal systems and all other elevator signal and accessory equipment complete. All parts shall be of the original manufacturer s design and specification. 8. EMERGENCY CALL BACK SERVICE: Prompt emergency call back service shall be provided on site within two (2) hours in response to requests (telephone or otherwise) from the Engineering Officer or his designee in case of shutdown or any emergency trouble arising between scheduled service calls. This service shall be rendered at any hour of any day of the week at no extra charge, regardless of cause. The serviceman responding to the call must personally call the person that made the service request and confirm that he/she is enroute to the medical center. If a serviceman is not immediately available, the office receiving the call must be notifying the person that made the service request stating the length of time of delay. Contractor will be advised at that time if the service call can be deferred. If prompt response is not available, the Government reserves the right to procure services from a noncontract source and bill the excess costs to the Contractor if deemed necessary. The Government will be the sole judge in making this determination. No overtime or travel will be charged. A local contact from within a 50-mile range of the VAMC, must be made available to respond to emergency calls. The contractor shall enter below the addresses and telephone numbers of the office which will receive calls for service: REGULAR HOURS OF BUSINESS: Hours______________________________________________________ Address____________________________________________________ Telephone Number ___________________________________________ OTHER THAN REGULAR HOURS OF BUSINESS: Address ____________________________________________________ Telephone Number___________________________________________ 9. REPORT OF SERVICE: Upon completion of all/any services, the Contractor shall report to the Facilities Engineering Officer or his designee and a written report of services performed shall be furnished for each service call. Report shall state corrective action taken. Quarterly reports shall be submitted in January, April, July and at the end of the contract period. Reports shall list each roped elevator separately and shall be specific as to rope condition, i.e. tension, lubrication and wear. 10. RECORDS: Contractor shall maintain a complete, orderly, and chronological file including drawings, parts lists, and copies of all reports as required by these specifications. A record of all call backs and repairs shall be kept indicating any difficulty experienced and corrective measures taken to eliminate difficulties. This file shall be available for inspection upon request, and a copy of this complete file will be furnished each VAMC during the last month of the contract period. 11. HOURS OF WORK: Work required in the performance of this contract shall be performed during the medical center s regular administrative working hours, 8:00 am to 4:30 pm weekdays. Contractor shall provide prompt emergency service 24 hours per day, seven days per week, including holidays. Upon arriving at the installation to perform services, the Contractor shall report to the Engineering Officer or his designee. (After working hours report to Boiler Plant in building 10 and call +1 (555) 000-0000 extension 3068). All work requiring the interruption of service, will require notification to and concurrence by the Engineering Officer. Interruption of service is work requiring shutdown for more than fifteen (15) minutes at any one time. 12. LOG: The Contractor shall maintain a log of services performed in the VAMC Facilities Engineering Service. The log shall list the date and time of all maintenance service and trouble calls. Each trouble call shall be fully described, including the nature of the call, necessary correction performed and/or parts replaced. The log will be kept in each elevator equipment room. 13. MAINTENANCE SERVICES: The maintenance service specified in this solicitation shall not include the performance of any work required as a result of improper use, accident, or negligence for which the Contractor is not directly responsible. 14. INSPECTION OF PREMISES: Potential offerors may inspect VAMC premises prior to submitting proposals in order to be fully aware of the scope of the services required. Failure to inspect all premises will not relieve the successful offeror from performing in accordance with the strict intent and meaning of the specifications. Appointments can be made with the following Engineering Service personnel, the Contracting Officer s Representative (COR): Maintenance Supervisor. END OF SPECIFICATIONS

More opportunities from Department Of Veterans Affairs → Network Contract Office 23 (36C263)

Same awarding agency

NAICS: 811310
New
Federal
J039--JLG Boom Lift Hydraulic Leak Repairs - STC (VA-27-00010304)
Solicitation # 36C26327Q0084
The Department of Veterans Affairs, Network Contracting Office 23, is issuing a sources sought notice for market research to identify qualified contractors for hydraulic repairs on a JLG Boom Lift, Model 600S, at the St. Cloud VA Health Care System in Minnesota. Under NAICS code 811310, the required services include replacing all hydraulic hoses through the cat track, replacing the hydraulic line from the pump to the block, replacing hydraulic oils, and updating the basket display decal and operator and ANSI manuals. The selected contractor must be located within a 100-mile radius and will be responsible for the pickup and delivery of the equipment to and from the St. Cloud VA campus. All repairs must be completed within three weeks of the contract award and must meet industry and manufacturer operational standards. This notice is not a formal solicitation and does not obligate the government to award a contract. Interested parties must submit their company information, including DUNS and SAM Unique Entity ID, a capability statement, and their socio-economic size classification to Contract Specialist Evan Beachy by 4:00 PM Central Time on November 04, 2026. Additionally, respondents should specify if the procurement can be handled through GSA, FSS, SEWP, or other existing contract vehicles. Responses are intended solely for planning purposes to help the government make informed acquisition decisions.
Commercial and Industrial Machinery and Equipment (except Automotive and Electronic) Repair and Maintenance

POSTED

1 day ago

DEADLINE

in 6 days
View Details
NAICS: 811210
New
Federal
J065--Karl Storz Support Services IDIQ VISN
Solicitation # 36C26327Q0022
The Department of Veterans Affairs Network Contracting Office 23 is soliciting a brand-name only, five-year Indefinite Delivery, Indefinite Quantity (IDIQ) contract for OEM-certified support and service of Karl Storz OR1 Video Integration Systems across the VISN 23 Healthcare System. This requirement, managed under simplified acquisition procedures, covers multiple locations including Minneapolis, St. Cloud, Fargo, Central Iowa, Iowa City, Black Hills, and Sioux Falls. The scope of work includes preventive and corrective maintenance, replacement parts, software and firmware updates, cybersecurity compliance, and technical training for clinical and biomedical staff. The contract has a guaranteed minimum value of 300,000 dollars and a maximum lifetime cost limitation of 5,600,000 dollars. Award will be based on a comparative evaluation of price and technical factors, including vendor qualifications, cybersecurity capabilities, and service level agreement response times. The contractor must adhere to strict OEM standards, NIST calibration requirements, and VA security policies, including the submission of cybersecurity artifacts and a signed Business Associate Agreement for HIPAA compliance. Performance will be monitored via a Quality Assurance Surveillance Plan targeting 98.9 percent operational uptime and 99 percent response time rates. Offers are due by November 11, 2026, and must include a signed SF 1449, completed pricing schedules, and proof of OEM certification for technicians.
Electronic and Precision Equipment Repair and Maintenance

POSTED

2 days ago

DEADLINE

in 13 days
View Details
NAICS: 238330
New
Federal
Replace Operating Room 5 Flooring
Solicitation # 36C26327Q0019
Solicitation 36C26327Q0019 is a Service-Disabled Veteran-Owned Small Business set-aside for the Department of Veterans Affairs, Network Contracting Office 23. The project involves providing all labor, materials, tools, and supervision to remove and replace the flooring and subflooring in Operating Room 5 (Room 4211, Building 1W) at the Des Moines VA Medical Center in Iowa. The work must be completed within 120 calendar days following the Notice to Proceed. Award will be granted to the responsible, eligible quoter who submits the lowest-priced acceptable quotation that meets all solicitation requirements, provided the price is determined to be fair and reasonable. Key technical requirements include conducting asbestos survey testing, adhering to the Architectural Design Manual, and utilizing certified installers through INSTALL or a comparable four-year apprenticeship program. The contractor must provide a floor tile mockup of 100 square feet to establish quality standards and comply with strict packaging and marking regulations for asbestos waste and HEPA filters. Administrative requirements include the submission of an Accident Prevention Plan and Site-specific Safety Plan for COR approval, as well as the provision of payment bonds or irrevocable letters of credit for contracts exceeding 35,000 dollars. The contract is subject to the Davis-Bacon Act and Buy American requirements, with specific limitations on subcontracting to ensure a minimum of 15 percent of the work is performed by the prime SDVOSB contractor.
Flooring Contractors

POSTED

2 days ago

DEADLINE

in 5 days
View Details
NAICS: 238220
New
Federal
J045--Glycol Loop Flushing - NWI
Solicitation # 36C26327Q0060
Solicitation 36C26327Q0060 is a firm fixed price request for quotation issued by the Department of Veterans Affairs Network Contracting Office 23 for the flushing, cleaning, and recharging of two closed-loop glycol heating systems, specifically the Surgery and Microbiology loops, at the Omaha VA Medical Center. The project requires the contractor to provide all labor, materials, equipment, and disposal handling to restore the systems to a stable operating condition using propylene glycol-based heat transfer fluid. The anticipated period of performance runs from November 1, 2026, to October 31, 2027, with the initial service required within 30 calendar days of award and a second identical service performed approximately 12 months later. Work must be conducted during normal business hours when temperatures exceed 40 degrees Fahrenheit and must comply with NFPA-99, ASHRAE 170, CMS, JCAHO, and VA HVAC Design Manual standards. This procurement is a total set-aside for Service-Disabled Veteran-Owned Small Businesses (SDVOSB), with strict limitations prohibiting the contractor from paying more than 50 percent of the government-paid amount to non-certified SDVOSB or VOSB firms. Award will be based on a comparative evaluation of price, technical quality, past performance, and veterans involvement. Key deliverables include pre-flush fluid sampling reports, system volume calculations, refractometer readings, and disposal manifests. Following Amendment 0001, the response deadline has been extended to November 10, 2026. Proposals must be submitted electronically to the contracting officer and include separate volumes for administrative documents, technical and past performance narratives, a subcontracting statement, and a labor standards statement confirming compliance with Service Contract Labor Standards.
Plumbing, Heating, and Air-Conditioning Contractors

POSTED

6 days ago

DEADLINE

in 12 days
View Details

Earlier notices in this NAICS code

Posted before this notice, open and closed

Find Active Opportunities Like This

Get AI-powered intelligence on the opportunities still open

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS