Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, November 11 at 2:00 PM ET

Register Free →

This Sources Sought opportunity from Department Of Veterans Affairs was posted on March 3, 2026. The submission period has ended. Browse the details below for market research, or find similar active opportunities.

J041--Liebert Air Conditioning Maintenance

Closed
36C24226Q0395Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

Active Opportunities Like This One

General Info

NAICS

333415 - Air-Conditioning and Warm Air Heating Equipment and Commercial and Industrial Refrigeration Equipment Manufacturing

Place of Performance

Department of Veterans Affairs James J. Peters VA Medical Center, Bronx, NY, 10468

Set-Aside

NONE

Documents

1

Sources Sought Notice 36C24226Q0395 Liebert Air Conditioning Maintenance

DOCX, High priority: read this firstsources-sought
High

AI Contract Breakdown

Uniform Contract Format

Sign up to view the full breakdown with detailed analysis of each section.

Timeline

PhaseClosed
Posted

Sources Sought

Response Deadline

Deadline has passed

Submission Closed

Find active opportunities like this

Get full access to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyDepartment Of Veterans Affairs → 242-NETWORK Contract Office 02 (36C242)
Contacts1 person available
OfficeALBANY, NY, 12208, USA
Office AddressALBANY, NY, 12208, USA
Contacts
Leia LaBrunaContract Specialist

Full Description

Show more
This is a Sources Sought Notice
(a) The Government does not intend to award a contract on the basis of this Sources Sought or to otherwise pay for the information solicited.
(b) Although "proposal," "offeror," contractor, and "offeror" may be used in this sources sought notice, any response will be treated as information only. It shall not be used as a proposal.
(c) Any information received from a contractor in response to this Sources Sought may be used in creating a solicitation. Any information received which is marked with a statement, such as "proprietary" or "confidential," intended to restrict distribution will not be distributed outside of the Government, except as required by law.
(d) This Sources Sought is issued by Network Contracting Office 2 (NCO 2) for the purpose of collecting information on Liebert Air Conditioning Maintenance for the James J. Peters VA Medical Center. The VA is seeking to provide for this requirement as of 5/1/2026 to establish a new service. The NAICS code identified for this requirement is 333415 Air-Conditioning and Warm Air Heating Equipment and Commercial and Industrial Refrigeration Equipment Manufacturing. The requirement is detailed in the Statement of Work section of this document.
(e) Contractors that are able to meet the requirements in the attachment are encouraged to email a capability statement and full information to contact@example.gov by Tuesday, March 10, 2026 by 4:00PM EST.
- Part of the purpose of this sources sought is to determine the viability of set aside to a specific socio-economic category. Contractors shall identify the NAICS code for the services being offered as well as their size status under said NAICS. If contractor is a Service-Disabled Veteran Owned Small Business (SDVOSB), a Veteran Owned Small Business (VOSB), or any other special category of contractors, then contractor is responsible for providing documentation in support of this. This information will be used to determine the viability of a set aside for this requirement. If any of the requested information is not supplied with the package, this may result in the contractor not being considered in the Government s Procurement Strategy.
- Contractors shall also identify any Federal Supply Schedules that may carry the desired services. - Contractors shall identify pertinent points of contact for company, socioeconomic verification in SAM and SBA, as well as for any intended subcontractors. - Contractor shall provide 2 to 3 instances of experience which demonstrate that they are a firm regularly engaged in this type of work, to include subcontractors for those jobs. - Contractor shall provide a listing of any teaming agreements they intend to employ in the performance of this requirement if awarded. - Contractor shall supply proof of any applicable certification or training required to meet the regulatory requirements, if applicable.
STATEMENT OF WORK Liebert systems, CLC cooling units, Building 16 cooling units. Background: The Department of Veterans Affairs (VA) James J. Peters VA Medical Center (JJP-VA) has a requirement for onsite maintenance and repair services for the equipment noted in the Equipment list section below. These units are in Building 100 and Building 16 and the CLC Center. 130 West Kingsbridge Road Bronx New York 10468.The JJP-VA intends to make a firm fixed price award for a 12-month base period with four 12-month option years. Scope of Work: This maintenance and repair service contract covers all management, supervision, labor, materials, supplies, parts, tools, equipment, reports and coordination to ensure the completion of all work and services noted, to fully maintain the equipment identified in this statement of work. The contract shall include preventative maintenance visits and on-site remedial repair service visits, as deemed necessary by the contractor or the JJP-VA. The service (visit) response time is 4 hours from the JJP-VA placing a call requesting service. This response includes weekdays, nights, weekends, and holidays. Period of Performance: Base Year: 5/1/2026-4/30/2027 Option 1: 5/1/2027-4/30/2028 Option 2: 5/1/2028-4/30/2029 Option 3: 5/1/2029-4/30/2030 Option 4: 5/1/2030-4/30/2031
Place of Performance: James J. Peters VA Medical Center 130 West Kingsbridge Rd. Bronx, NY 10468 Building 100 and Building 16 Scope of Service: Preventive Maintenance:
Preventative maintenance frequency is outlined by equipment in the equipment list chart below. The Contractor shall be responsible for performing all routine maintenance and repair work required to maintain the Cooling Units in the condition prescribed by the original equipment manufacturer s recommended guidelines and/or warranty requirements where the warranty remains in force. The Contractor shall provide a mix of semiannual and quarterly preventative maintenance calls each year. The contractor shall examine, test, adjust the equipment, and as conditions warrant, repair or replace parts in accordance with original equipment manufacturer standards. The contractor shall maintain the Cooling Units at levels necessary to provide the specified functions to meet the manufacturer s current equipment specifications. The contractor shall furnish all personnel, materials, labor, parts, supplies, travel, supervision and equipment required to perform work under the resulting contract, to include but not limited to, tools and expendable items. The contractor shall provide one designated point of contact (POC) to the government s designated representative for coordination of parts delivery, and/or maintenance. The POC will be empowered to make daily decisions to ensure that the contract implementation and day to day maintenance meet the terms and conditions of the resulting contract. The contractor shall provide a toll free telephone number for service calls, which must be answered during at least eight working hours, between 8:00 am and 4:30 pm, Monday through Friday in addition to all hours for emergency service. Parts, supplies and availability. The contractor shall have an inventory of parts and supplies in quantities sufficient to effectively service the resulting contract. The contractor should have an internal inventory system and delivery system for the parts and supplies. The inventory and delivery system must be sufficient to service the contract in accordance with the maintenance response times specified in paragraph The contractor shall use only new parts supplied by the manufacturer. After completion of the work, the service technician is required to remove old parts and supply items from the work site. The contractor shall provide at each service visit documentation related to repair work or preventative maintenance conducted.
Maintenance Inspections:
This synopsis is for estimating purposes only. The contractor is required to follow all manufacturers recommendations for preventative maintenance, service, and repair work. Record temperature set points at each unit and provide dedicated documents to track any changes. Inspect electrical connections, relays, and all controls for proper operation. Check belt tension and condition (replace if applicable). Check pulleys and motor mounts. Check humidifier and adjust operating controls, if applicable. Lubricate fan bearings per manufacturer s recommendations. Lubricate motor bearings per manufacturer s recommendations. Check fan safety switch, if applicable. Check belt tension and condition, if applicable. Check pulleys and motor mounts, if applicable. Check and clean coils. Check and clean drain pans and drain. Check filters and replace them as needed. Check filter switch, if applicable. Check fan motor and record amp readings, if applicable. Inspect electrical connections, contractors, relays, and operating/safety controls. Check compressor oil level, test oil, meg motor. Record refrigerant pressures, check site glass for clear and dry conditions. Check compressor operating conditions and adjust as required. Check humidifier and adjust operating controls. Clean unit exterior.
Reporting:
The contractor shall provide service reports on all services performed, to include operational and comprehensive maintenance according to the manufacture s recommendations. Service reports shall include a summary of the services performed, deficiencies identified and recommendations if needed. Reports shall be provided to the COR no less than 3 business days after service is completed. Repairs identified by the contractor shall require prior approval by the contracting officer.
Equipment List:
The following table includes the model, serial number, brand and description for the equipment covered in this contract. All the units are located at 130 West Kingsbridge Road, Bronx, NY 10468. All equipment is currently in good working conditions.
Maintenance schedule Manufacturer Model (1) Quarterly maintenance schedule Libert BF067ASAD0I476A (1) Quarterly maintenance schedule Libert BF067ASAD0I476A (1) Quarterly maintenance schedule Libert BU068C-ADEI593A (1) Quarterly maintenance schedule Libert BU068C-ADEI593A (1) Quarterly maintenance schedule Libert MMD23C2XHE00 (1) Quarterly maintenance schedule Libert PX018UW1A8S738 (1) Quarterly maintenance schedule Libert BU068C-ADEI186S (3) Quarterly maintenance schedule LG Bld 16 ARUM168DTE5 (22) Semiannual maintenance schedule Mitsubishi PLFY-P15NFMU-E (4) Semiannual maintenance schedule Mitsubishi PVFY-P24NAMU-E1 (64) Semiannual maintenance schedule LG wall units ARNU153SJA4
Compliance and Safety Requirements: While in performance of the resultant contract, the contractor shall maintain safety and health standards compliant with the requirements of the Occupational Safety and Health Administration (OSHA). All work shall be completed in accordance with the following regulations. ANSI/ASHRAE 180-2018, VHA directive 1811,1002.1, NFPA 90-A-2024, IMC 1101.6-2024. Contractor Qualifications: The contractor shall be required to provide fully qualified and trained service technicians to include: EPA Section 608 certification HVAC Excellence and NATE (North American Technician Excellence)
Security Requirements: Upon entering JJP-VA buildings the contractor and/or contractor employees will be required to show proof of identity (must have a valid photo ID) as well as pass through a security screening. Regarding information and information system security. Vendors should be always escorted in the VA office buildings. The contractor will be accompanied by designated government personnel and shall sign in upon arrival. Services will not require connection to the VA network. The C&A requirements do not apply; a Security Accreditation Package is not required. At no time during the execution of the duties listed in this statement of work will the contractor interface with VA systems or VA sensitive information. Personnel Requirements: The contractor shall provide one designated point of contact (POC) to the government s designated representative for the coordination of maintenance. The contractor shall provide technicians with 3-5 years of mechanical experience with service and maintenance on equipment noted in this SOW. Delivery personal, management personnel and service techs shall be sufficiently supported by the contractor to service this maintenance contract. The contractor should use only new OEM parts.
Work Hours and Scheduling Arrangements: Except by special alternative arrangement, scheduled preventive maintenance/services will be performed only during the facility s normal business hours (8:00 a.m. to 4:30 p.m. Monday through Friday excluding federal holidays). Downtime for preventive maintenance/services must be scheduled through the Contracting Officer Representative (COR) at least 2 days in advance. When downtime for service/repairs is needed, the contractor shall notify the COR the same day (as soon as possible) upon observation. The Federal Holidays which are observed by the federal government are annotated below. -New Year s Day -Martin Luther King s Birthday -President s Day -Memorial Day -Independence Day -Labor Day -Columbus Day -Veterans Day -Thanksgiving Day -Christmas Day -Any other day specifically declared to be a national holiday (per Federal Statute, Executive Order, or by the President s Proclamation).

More opportunities from Department Of Veterans Affairs → 242-NETWORK Contract Office 02 (36C242)

Same awarding agency

NAICS: 238210
New
Federal
Y1DA--Project620-22-110 Replace and Upgrade Fire alarm System at Montrose VAMC
Solicitation # 36C24227B0009
Solicitation Number 36C24227B0009 is a 100 percent Service Disabled Veteran-Owned Small Business (SDVOSB) set-aside for the Department of Veterans Affairs. The project involves a multi-phased campus-wide replacement and upgrade of the fire alarm system at the FDR VA Medical Center, Montrose Campus in New York. The contractor will replace the existing, unreliable Edwards system with a 2026 Honeywell Notifier Fire alarm system featuring intelligent addressable technology. This new system must meet all NFPA codes and guidelines, providing capabilities such as sensitivity reporting, maintenance notifications, and control functions for HVAC fan shutdowns, elevator controls, and the releasing of locked doors. The magnitude of construction for this project is estimated between 2,000,000.00 and 5,000,000.00 dollars, falling under NAICS Code 238210 with a size standard of 19 million dollars. The period of performance is 550 calendar days from the Notice to Proceed. Eligible bidders must be registered in SAM.gov and Duns and Bradstreet, and verified as an SDVOSB through the SBA certification portal. All submissions must be emailed by the deadline of December 16, 2026, at 10 AM Eastern Time, as hand-carried bids will not be accepted. This project also requires bonding.
Electrical Contractors and Other Wiring Installation Contractors

POSTED

about 8 hours ago

DEADLINE

in about 2 months
View Details
NAICS: 541350
New
Federal
H399--36C242-27-AP-0524| 528-27-1-6893-0009 Elevator Inspections, Base (4) Canandaigua VA Medical Center (VAMC) & Bath VA Medical Center (VAMC)
Solicitation # 36C24227Q0041
The Department of Veterans Affairs, Network Contracting Office 2, is soliciting quotes for third-party elevator inspection services at the Canandaigua and Bath VA Medical Centers in New York. This SDVOSB set-aside contract requires a Qualification of Elevator Inspectors (QEI)-Certified Inspector to witness and document semi-annual safety inspections, annual pressure and no-load tests, and five-year full-load tests. All work must comply with the most current editions of ASME A17.1 and ANSI/ASME 17.2 standards. Results must be documented using VA Form 10-6166, and the contractor is responsible for verifying that maintenance check charts are current and correctly annotated. The period of performance consists of a base year running from November 1, 2026, to October 31, 2027, with four subsequent 12-month option years, with services typically performed in April and October. Award decisions will be based on technical capability, past performance, and price, with the government reserving the right to use a trade-off process for additional benefits. Offerors must submit a technical capability statement of no more than 10 pages and a statement of acceptance regarding the solicitation terms and conditions by October 29, 2026. The contract incorporates various FAR and VA clauses, including specific requirements for electronic payment, personnel vetting, and supplemental insurance.
Building Inspection Services

POSTED

about 8 hours ago

DEADLINE

in about 22 hours
View Details
NAICS: 325120
New
Federal
6835--VISN 2 Prosthetics Downstate Home Oxygen Services
Solicitation # 36C24226R0081
Solicitation 36C24226R0081 is a request for proposals issued by the Department of Veterans Affairs, Samuel S. Stratton VA Medical Center, for Home Oxygen Services to benefit veterans within the VISN 2 Downstate New York Healthcare Network, including the Bronx, Hudson Valley, New Jersey, New York Harbor, and Northport areas. This Service-Disabled Veteran-Owned Small Business set-aside contract covers a base period from January 1, 2027, through December 31, 2027, with five subsequent option periods extending through June 30, 2032. The scope of work includes the rental and maintenance of oxygen concentrators, liquid oxygen systems, and ventilators, as well as the provision of Registered Respiratory Therapist visits and the mandatory use of thermal fuses for safety. The estimated contract value ranges from a minimum of 100,000 dollars to a maximum of 40 million dollars. Award decisions will be based on a best value trade-off process where non-price factors, including technical capability, past performance, and SDVOSB/VOSB status, are significantly more important than cost. Technical evaluations focus on Joint Commission accreditation, 24/7 service capabilities with a four-hour response time, and a transition plan requiring full implementation within 180 calendar days of award. Contractor performance will be systematically monitored through a Quality Assurance Surveillance Plan involving patient satisfaction surveys, random audits of equipment installation, and monthly inventory reviews. Proposals must be submitted electronically in PDF format to Contract Specialist Corey Swinton by the final deadline of February 10, 2027.
Industrial Gas Manufacturing

POSTED

about 8 hours ago

DEADLINE

in 4 months
View Details
NAICS: 236220
New
Federal
Building 13 Stair and Roof Replacement at Castle Point VAMC
Solicitation # 36C24227B0002
Solicitation 36C24227B0002 is a firm-fixed-price sealed bid for the repair of exterior architectural features at Building 13 of the Castle Point VA Medical Center in Wappingers Falls, New York. The project scope includes tuckpointing, brick repair and replacement, structural stair reconstruction, and the complete removal and installation of roofing systems to prevent water infiltration and restore proper egress. Additional requirements include asbestos remediation and adherence to a tuberculosis control plan. The estimated magnitude of construction is between 500,000 and 1,000,000 dollars, with a performance period of 180 calendar days from the Notice to Proceed. This procurement is a 100 percent set-aside for Service-Disabled Veteran-Owned Small Businesses (SDVOSB) under NAICS code 236220. Bidders must be registered in SAM and provide a bid bond, a Buy American Certificate, and a Certificate of Compliance regarding subcontracting limitations. Due to the facility's 24/7 operation, the contractor must coordinate all service interruptions with the Contracting Officer's Representative and utilize the VISN 2 Autodesk Build Construction management platform. Personnel are subject to strict vetting, fingerprinting, and identification card processing before beginning work. Bids must be submitted electronically to the Contracting Officer by November 4, 2026.
Commercial and Institutional Building Construction

POSTED

about 8 hours ago

DEADLINE

in 13 days
View Details

Earlier notices in this NAICS code

Posted before this notice, open and closed

Find Active Opportunities Like This

Get AI-powered intelligence on the opportunities still open

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS