J046--Intent to Sole Source Deionized water system service

Awarded
36C24626Q1102Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

Active Opportunities Like This One

AI Contract Overview

Show more

The Department of Veterans Affairs, Network Contracting Office 6, is conducting market research through a sources sought notice to identify qualified businesses capable of providing service and maintenance for the Evoqua Deionized Water System at the Richmond VA Medical Center. This procurement, categorized under NAICS code 561990, focuses on ensuring system reliability and compliance with regulatory water-quality and laboratory standards. The scope of work includes recurring annual preventive maintenance, pump inspections, flow and pressure adjustments, and the cleaning and sanitization of distribution loops to prevent microbial growth. Technical requirements specifically mandate regular conductivity testing and Silt Density Index testing to monitor water purity and particulate loading. The contractor will be responsible for providing various OEM consumable parts and replacement components, including UV lamps, quartz sleeves, O-rings, and specific filter cartridges. Additionally, the requirement includes the provision of DI media tanks, specifically mixed-bed and activated carbon fiberglass pots. Interested vendors must demonstrate the ability to perform maintenance according to the manufacturer's PMI schedule and provide the necessary labor and OEM parts. Responses for this market research effort are due by September 24, 2024, at 10 am EST via email to the designated contract specialist.

General Info

VA seeks qualified vendors for Evoqua Deionized Water System maintenance at Richmond Medical Center.

NAICS

561990 - All Other Support Services

Place of Performance

VA

Set-Aside

NONE

Documents

2
DOCX, Low prioritysources-sought
Low
DOCX, Low priorityspecial-notice
Low

AI Contract Breakdown

Uniform Contract Format

Sign up to view the full breakdown with detailed analysis of each section.

Timeline

1 update
PhaseAwarded
Posted

Sources Sought

Notice updated

Notice type changed from Sources Sought to Special Notice. Response deadline changed from Sep 24, 2026 to Oct 1, 2026. The notice title changed. The notice description changed.

Awarded

Contract was awarded

Submission Closed

Find active opportunities like this

Get full access to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyDepartment Of Veterans Affairs → 246-NETWORK Contracting Office 6 (36C246)
Contacts1 person available
OfficeHAMPTON, VA, 23667, USA
Office AddressHAMPTON, VA, 23667, USA
Contacts
Cedric FrasierContract Specialist

Full Description

Show more
NOTICE OF INTENT TO SOLE SOURCE
The Department of Veterans Affairs, Veterans Health Administration, Network Contracting Office 6, intends to award a Firm Fixed Price Sole-Source contract to Evoqua Water Technologies. The Richmond Veterans Affairs Medical Center (VAMC) has a request for Evoqua Water Technologies, for preventative maintenance service. The justification for this non-competitive solicitation is due to Evoqua Water Technologies, being the sole supplier of requested service to the VA Hospital and Health Care Center. The NAICS code for this procurement is 561990 All Other Support Services $16.5 million. The Sole source service is: Service & Maintenance Items W3TSP3006 Fuel/Energy Surcharge Fixed surcharge applied per service visit. Supports technician travel and operational energy costs needed to perform DI system maintenance. W3TSP3011 PM Contract Recurring (Parts & Labor) Provides recurring annual preventive maintenance for the DI system. Includes all required labor and OEM parts. Ensures system reliability and compliance with regulatory water-quality requirements. W3TSP4346 Conductivity Readings & Record Data Contractor performs conductivity testing of DI water output. Readings ensure water purity meets laboratory standards. W3TSP4408 Adjust Flows and/or Pressures Technician adjusts internal system flows and pressures. Ensures optimal DI production performance and protects downstream equipment. W3TSP4417 Inspect Pumps Inspection and verification of pump condition and operation. Identifies wear, misalignment, inefficiency, or potential failures. W3TSP4418 SDI Test and Record Data Silt Density Index (SDI) testing performed regularly. Indicates particulate loading and pretreatment performance. W3TSP4601 Perform & Replace Prefilter Maintenance per PMI Replacement of prefilters according to manufacturer PMI schedule. Maintains upstream filtration integrity and protects DI media tanks. W3TSP4708 Clean or Sanitize Distribution Loop Full loop cleaning and sanitization using approved disinfectant processes. Prevents microbial growth and maintains water purity throughout distribution. ________________________________________ Consumable/Replacement Parts W2T159701 20" 5µm MB CDF PP Plyfm Cartridge 20-inch depth filter cartridge. 5-micron nominal rating. Multi-bed (MB) CDF polypropylene construction. Removes particulates prior to DI processing. W2T850795 UV Lamp (24W, 254nm, Single-End, 4-Pin) 24 watt ultraviolet germicidal lamp. 254 nm wavelength for microbial reduction. Single end, 4 pin configuration compatible with Evoqua UV housing. W2T850799 Quartz Sleeve QS535 Quartz protective sleeve for UV lamp insertion. Maintains lamp isolation from water stream while ensuring UV penetration. W2T850802 O Ring, LF UV System OEM O ring seal designed for UV system housing. Ensures watertight sealing and prevents bypass leakage. W2T850803 Washer, LF UV Systems OEM washer component for UV lamp housing assembly. Maintains correct compression and secure hardware alignment. W2T918450 20" 0.2µm PLT CDF ABS PS1 SIL Cartridge 20 inch, 0.2 micron absolute-rated cartridge. Designed for final particulate and microbial filtration. Polymer structured (ABS/PS1 SIL) configuration. W2T934633 NIL-8 Test Strip (PAA), 50/Test Tube Test strips for peracetic acid concentration monitoring. Used during sanitization procedures. W2T934634 NIL-8 Test Strip (H O ), 50/Test Tube Hydrogen peroxide concentration test strips. Supports verification of sanitizer effectiveness. W2T936744 NIL-8 Sanitizer (1.5 Gallons) Sanitizing agent used for loop disinfection. Compatible with Evoqua systems and lab water distribution materials. ________________________________________ DI Media Tanks W5TDIMB10360FSP SDI Mixbed 3.6 CF FBGLS STD Pot Mixed-bed deionization tank (3.6 cubic feet). Fiberglass standard pot design. Removes ionic contaminants producing high-purity DI water. W5TDIRAC0360FSP SDI React Carbon 3.6 CF FBGLS STD Pot Activated carbon tank (3.6 cubic feet). Fiberglass standard pot construction. Removes chlorine/chloramine and organics upstream of DI beds. THIS NOTICE IS NOT A REQUEST FOR COMPETITIVE QUOTES, and no Solicitation will be issued. Market research has determined that this product is highly specialized and only available from a single source without an unacceptable delay or duplication of cost and no other type of supply will satisfy agency requirements. The Government intends to award the contract with an effective date on or about October 7, 2026, to Evoqua Water Technologies, 105 47TH ST , Pittsburgh, Pennsylvania 15201.
However, interested parties may identify their skill and ability by sending capability statements about this requirement to the Contracting Specialist within three (3) calendar days (October 1, 2026 @ 10am est) of this publication by contacting Cedric Frasier via e-mail contact@example.gov. Telephone inquiries will not be accepted. Those interested firms must indicate whether they are large, small, small-disadvantaged, 8(a), or woman-owned businesses and whether they are U.S. or foreign-owned. Respondents who submit proprietary data shall clearly mark the data with appropriate markings. The Government will not pay for any information submitted as a result of this synopsis. This synopsis shall not be construed as an obligation on the part of the Government to acquire any products or services.

More opportunities from Department Of Veterans Affairs → 246-NETWORK Contracting Office 6 (36C246)

Same awarding agency

NAICS: 333415
New
Federal
N044--REPLACE AIR SEPARATOR AND RELOCATE
Solicitation # 36C24627Q0071
The Department of Veterans Affairs, Network Contracting Office 6, is soliciting a firm fixed price contract for the repair, replacement, and relocation of an air separator. This unrestricted procurement, identified by solicitation number 36C24627Q0071, falls under NAICS code 333415. The scope of work requires the contractor to shut down the steam system for safety, perform the necessary installation and relocation tasks, and restart the system to verify proper operation. All work must adhere to VAMC, federal, state, and local safety regulations. The contract includes specific requirements for packaging, stating that packing slips must accompany all deliveries and any defective equipment must be replaced at no cost to the government or Richmond VAMC. Quotes are due by November 14, 2026, at 11 AM and must be submitted via email to the Contracting Officer, Audrey Wooten. Submissions must include an SF 1449 and a technical description featuring product descriptions, photos, and model numbers. Award decisions will be based on a combination of price and technical factors, with technical quotes rated as either acceptable or unacceptable. The procurement is designated as HUBZone Small, and offerors must be registered in the System for Award Management (SAM) to be eligible. Additionally, the contract incorporates various FAR clauses regarding whistleblower rights, sustainable products, and security prohibitions, including restrictions on specific telecommunications and video surveillance equipment.
Air-Conditioning and Warm Air Heating Equipment and Commercial and Industrial Refrigeration Equipment Manufacturing

POSTED

about 15 hours ago

DEADLINE

in 5 days
View Details
NAICS: 541380
New
Federal
F103--D AND D LABORATORY STEAM & WATER TESTING
Solicitation # 36C24627Q0096
The Department of Veterans Affairs, Network Contracting Office 6, is soliciting quotes for laboratory steam and water testing services to support the Durham VA Medical Center and its Community Based Outpatient Clinics in Greenville and Garner, North Carolina. This requirement is a total set-aside for certified Veteran-Owned Small Businesses (VOSB). The scope of work involves monthly sampling and testing of critical and utility water systems to ensure compliance with standards for sterile processing services. Required tests include analysis for bacteria, endotoxins, pH, conductivity, alkalinity, and total hardness. The contract includes a base period from November 10, 2026, to November 9, 2027, with multiple option periods extending through November 9, 2031. Award will be based on the Lowest Price Technically Acceptable (LPTA) offer. Technical evaluations will focus on the offeror's management approach, capability to perform, and a history of at least two similar contracts completed within the last three years. Past performance will be assessed based on customer satisfaction and responsiveness. Successful contractors must submit a Quality Assurance Plan within 30 days of award and utilize the OB10 e-Invoicing network for monthly payments in arrears. The final deadline for the receipt of offers is November 20, 2026, at 9:00 AM EST.
Testing Laboratories and Services

POSTED

1 day ago

DEADLINE

in 9 days
View Details
NAICS: 811210
New
Federal
J066--GRECC Preventive Maintenance Contract, Durham VAMC
Solicitation # 36C24627Q0092
The Department of Veterans Affairs, Network Contracting Office 6, is soliciting a firm-fixed price contract for bi-annual preventative maintenance, calibration, and emergency repair services for centrifuges and other laboratory instruments at the Durham VA Medical Center Geriatric Research, Education, and Clinical Center in Durham, North Carolina. This requirement is a total small business set-aside under NAICS code 811210. The scope of work includes cleaning, calibrating, and performing run tests on specific equipment, such as Beckman Superspeed and GPR centrifuges, Eppendorf refrigerated centrifuges and micocentrifuges, Nuair Incubators, and Lab-Line shakers. All services must adhere to original equipment manufacturer standards and standard manufacturing practices. The contract is structured with a base period from April 1, 2027, to March 31, 2028, with three subsequent one-year option periods, allowing for a total duration of up to five years. Key performance requirements include completing maintenance by the last day of April and October each year and responding to emergency service calls within 24 hours. Award will be granted to the responsible offeror determined to be most advantageous to the government based on price and other factors. Prospective quoters must be registered in the System for Award Management and submit their quotes by November 12, 2026. Invoices are to be submitted electronically in arrears upon completion of work.
Electronic and Precision Equipment Repair and Maintenance

POSTED

1 day ago

DEADLINE

in 8 days
View Details
NAICS: 561210
New
Federal
H144--Steam Quality Testing Service
Solicitation # 36C24627Q0084
The Department of Veterans Affairs Network Contracting Office 6 is soliciting quotes for a firm-fixed-price, turn-key Steam Quality Testing Service at the Hampton VA Medical Center. This Small Business Set-Aside, designated for HUBZONE small businesses under NAICS 561210, requires the contractor to provide all personnel, equipment, and supplies to perform quarterly and annual steam quality testing for dryness and non-condensable gases. The scope of work includes installing steam sample points and conducting comprehensive steam, condensate, and water audits to evaluate SPD equipment installation and identify causes of wet loads or staining. Testing must adhere to ANSI/AAMI ST79 and ST108 standards, and the contractor must be certified in accordance with ISO 17665 and EN 285. The contract structure consists of a base year and four option years, with a total estimated contract value of 178,000 dollars and a base year cost of 32,400 dollars. Award will be based on a best value determination considering technical capability, past performance, and price. Proposals must include a signed SF 1449 and a separate technical proposal in PDF format that demonstrates the ability to meet the performance work statement without including pricing information. All services will be performed on-site at the Hampton VA Medical Center, and the contractor is required to maintain active SAM registration and comply with VA sensitive information and security protocols.
Facilities Support Services

POSTED

1 day ago

DEADLINE

in 10 days
View Details

Find Active Opportunities Like This

Get AI-powered intelligence on the opportunities still open

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS