J059--SOURCES SOUGHT NOTICE SWITCHGEAR MAINTENANCE TESTING SERVICES BALTIMORE VA MEDICAL CENTER 36C24526Q0196
Contract Overview
Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.
Active Opportunities Like This One
General Info
Place of Performance
Department of Veterans Affairs Baltimore VA Medical Center, Baltimore, MD, 21201, USASet-Aside
Documents
2AI Contract Breakdown
Uniform Contract FormatSign up to view the full breakdown with detailed analysis of each section.
View Full BreakdownThis one is closed. Find the next one like it.
Open contracts like this one, right now:
- 47463 ELECTRICALOpen now, due in 5 days
- Emergency and Exit Lighting InstallationOpen now, due in 21 days
Ask CLEATUS
I've read this contract. Ask me anything.
Timeline
Submission Closed
Organization & Contact Information
Full Description
Response Instructions: Responses must be submitted by 10:00 AM (ET) NLT 01-12-2026, Responses to the information requested above must be submitted via email to Bill Pratt at Sign up to see this detail Respond: 36C24526Q0196 Sources Sought Notice | Company Name This request for information/sources sought notice is for planning purposes ONLY and does not constitute a solicitation, responses to this notice are not offers and cannot be accepted by the Government to form a binding contract. The results of this market research will assist in the development of (1) the requirement, and (2) the acquisition strategy (e.g., SDVOSB/SDVOSB set-aside, small business set-aside, full and open competition, etc.).
Scope of Work:
NETA Maintenance Testing of GE PowerVac 15KV Switchgear Lineup Location: Department of Veterans Affairs, VA Hospital Baltimore, Maryland 1. SCOPE The purpose of this Performance Work Statement (PWS) is to define the requirements for the Contractor to perform NETA Maintenance Testing and inspection services on the GE PowerVac 15KV Switchgear Lineup located at the VA Hospital in Baltimore, Maryland. The contractor shall provide all labor, supervision, materials, test instruments, and equipment necessary to perform the work in accordance with the latest edition of ANSI/NETA Maintenance Testing Specifications (MTS), applicable ANSI, IEEE, NFPA, and manufacturer s recommendations. All testing shall be performed de-energized and coordinated with the VA to ensure minimal disruption to facility operations. 2.0 APPLICABLE DOCUMENTS AND STANDARDS The following documents and standards, or the latest revisions thereof, shall apply to the work performed under this PWS: ANSI/NETA MTS Standard for Maintenance Testing Specifications for Electrical Power Equipment and Systems NFPA 70 National Electrical Code (NEC) NFPA 70E Standard for Electrical Safety in the Workplace OSHA 29 CFR 1910 Subpart S Electrical Safety Requirements Manufacturer s published operation and maintenance manuals 3.0 EQUIPMENT TO BE TESTED The GE PowerVac 15KV Switchgear lineup consists of the following sections: BGE Utility Main #13708 (4) 51 mechanical relays (1) 86-2 lockout relay section (3) 87B differential relays (1) 27x-3, (1) 62x-3, (1) 27-3, (1) 60-3 mechanical relay BGE Utility Main #13709 (4) 51 mechanical relays (1) 86-2 lockout relay section (3) 87B differential relays (1) 27x-3, (1) 62x-3, (1) 27-3, (1) 60-3 mechanical relay Tie Breaker (13709 to 7835) (1) 27x-3, (1) 62x-3, (1) 27-3, (1) 60-3 mechanical relay Tie Breaker (13708 to 7835) (1) 27x-3, (1) 62x-3, (1) 27-3, (1) 60-3 mechanical relay (2) Metering compartment sections (1) PT/CT compartment for 13708 section (1) PT/CT compartment for 13709 section (7) Feeder breaker sections, each with (3) 50/51 mechanical relays and (1) 51GS mechanical relay (1) Ground and test device section (1) Section equipped for breaker spare 4.0 REQUIREMENTS AND PERFORMANCE TASKS 4.1 Switchgear and Bus Testing The contractor shall: Perform visual and mechanical inspection of all switchgear sections. Clean and torque all accessible bolted electrical connections. Conduct insulation resistance testing (phase-to-phase and phase-to-ground). Perform contact resistance testing of main bus and breaker stabs. 4.2 Circuit Breaker Testing (15KV PowerVac) The contractor shall: Conduct visual and mechanical inspection. Perform contact resistance and insulation resistance testing. Perform vacuum bottle integrity testing. Conduct primary current injection testing to verify trip operation. Perform mechanical timing and operation testing. 4.3 Protective Relay Testing (Electromechanical Relays) The contractor shall: Calibrate and functionally test all 51, 50/51, 51GS, 27, 27X, 60, 62, 86, and 87B relays per manufacturer tolerances. Verify control circuit continuity, wiring integrity, and tripping path functionality. 4.4 PT/CT and Metering Testing The contractor shall: Perform ratio, polarity, and insulation resistance testing. Perform burden and excitation testing where applicable. 4.5 Grounding Verification The contractor shall: Perform visual inspection of all grounding buses, connections, and hardware. Verify ground continuity and ground resistance. 4.6 Additional Functional Testing The contractor shall: Functionally test all mechanical and electrical interlocks and safety devices. Verify trip coordination as found and as left. 5.0 DELIVERABLES The contractor shall submit the following deliverables: Field Test Data Sheets for all tested equipment. Calibration Reports for all relays and devices. Summary Report indicating pass/fail status against NETA criteria. Deficiency List of any equipment not meeting performance standards. Final Comprehensive Test Report in both PDF and hard copy format. All reports shall include test values, instrument serial numbers, calibration dates, and technician signatures. 6.0 PERFORMANCE STANDARDS Task Performance Standard Acceptable Quality Level (AQL) Perform testing per NETA MTS and manufacturer standards 100% compliance No deviations Submit completed test report within 10 business days of testing 100% on time No late submissions Provide qualified NETA-certified technicians 100% compliance No unqualified personnel Maintain safety compliance (NFPA 70E/OSHA) 100% compliance No safety violations 7.0 GOVERNMENT RESPONSIBILITIES The VA Hospital shall: Provide access to the equipment and ensure system de-energization during testing. Coordinate and schedule required electrical outages. Provide existing drawings, single-line diagrams, and relay settings where available. 8.0 CONTRACTOR RESPONSIBILITIES The contractor shall: Provide all necessary test equipment, tools, and safety gear. Ensure all instruments are calibrated and traceable to NIST standards. Provide qualified NETA-certified or equivalent personnel to perform testing. Comply with all facility safety and security procedures. 9.0 EXCLUSIONS The following items are specifically excluded from the scope of this contract: Repairs or replacement of defective components. Changes to relay settings or updates to coordination studies. Temporary power generation or load bank services. Energized infrared thermography. Cleaning beyond standard wipe-down. Civil, structural, or rigging work related to equipment access. 10.0 SAFETY All work shall comply with applicable VA safety regulations, OSHA standards, and NFPA 70E. Personnel shall wear appropriate arc flash PPE, and all lockout/tagout procedures shall be followed before testing begins. SCHEDULE The contractor shall coordinate the testing schedule with VA Engineering and Facilities Management staff. A proposed testing plan and timeline shall be submitted for approval no later than 10 business days prior to mobilization. QUALITY ASSURANCE All test procedures and data shall conform to the NETA Maintenance Testing Specifications. The contractor s Quality Control Representative shall verify that all results are reviewed, signed, and certified prior to submission.
More opportunities from Department Of Veterans Affairs → 245-NETWORK Contract Office 5 (36C245)
Same awarding agency
Find Active Opportunities Like This
Get AI-powered intelligence on the opportunities still open
Every page of the solicitation package shredded into a compliance breakdown
AI-powered matching based on your capabilities and past performance
Competitor and incumbent history on the requirement
Automated alerts on amendments, Q&A deadlines, and award
Join 750+ contractors already using CLEATUS