Preventive Maintenance (PM) shall be performed by either the OEM, or a contractor certified by the OEM at intervals in accordance with the original equipment manufacturers (OEM) specifications. The contractor must provide documentation confirming current OEM certification and authorization to perform maintenance services. Contractor shall furnish any required PM kits, tools, manuals and materials needed to perform Preventative Maintenance. The contractor shall perform PM according to manufacturer s specifications. The contractor shall have written procedures to be followed and documented evidence that each piece of equipment has been inspected according to those procedures. Monthly Tasks: Replace sediment filters for CWP systems (two LD05 20 filters per visit). Replace sediment filters for each Marcor portable RO (GX05 10 per machine). Replace sediment filters for each AmeriWater Centurion RO cart (GX05 10 filter for each of 7 units). Inspect all equipment for proper function. Quarterly Tasks: Replace (2) 20 sediment filters for CWP systems. Replace (2) carbon block filters for each Millenium HX RO (2 systems). Replace (1) 10 sediment filter for each Millenium HX RO (2 systems). Provide chemicals to clean RO membranes on both CWP systems. Replace (1) GX05 10 filter for each of the 7 AmeriWater Centurion RO carts. Replace (2) 2.5 x 20 Chlorplus carbon blocks for 2 Centurion systems
Attachment 1: Equipment List
Manufacturer Equipment Name Model #: Serial #: Location: Acquisition Date Ameriwater Water Purification Systems Centurion CPM21019 2H Area 08/02/2023 Ameriwater Water Purification Systems Centurion CPM21020 2H Area 08/02/2023 Ameriwater Water Purification Systems Centurion CEN240015 2H Area 05/09/2024 Ameriwater Water Purification Systems Centurion CEN240013 2H Area 05/09/2024 Ameriwater Water Purification Systems Centurion CEN240009 2H Area 05/09/2024 Ameriwater Water Purification Systems Centurion CEN240012 2H Area 05/09/2024 Ameriwater Water Purification Systems Centurion CEN240007 2H Area 05/09/2024 Marcor Millenium HX 1369448 2H Area 09/07/2018 Marcor Millenium HX 1369426 2H Area 09/07/2018 Marcor CWP CWP 1369449 Water Room 04/01/2018
All respondents shall indicate/provide the following: Must demonstrate the ability to comply with the limitations on subcontracting in RFO 52.219-14 / VAAR 852.219-75, as applicable. In your capability statement, describe how your firm intends to comply with this limitation throughout performance. Is your company interested in providing a Federal Supply Schedule (FSS) quote or Open Market (indicate FSS contract #)? Identify any other companies owned (wholly or in-part) by the owners of this business who provide goods or services under the same or a related NAICS codes. Identify any other companies owned (wholly or in-part) by the owners of this business who provide goods or services that are registered under the same or a related NAICS code with the Center for Veterans Enterprise (CVE); Provide the certification type (SDVOSB/VOSB), Federal Identification Number, and state of incorporation for each. Whether or not your company has an active SAM registration and the companies Unique Entity Identifier. A copy of its capabilities statement. Failure to provide the above information may result in the potential offeror being considered incapable of meeting the VA s needs. If the contractor can provide the above items, the contractor shall provide a letter from the manufacturer stating they are an authorized distributor/licenser of their products. Failure to submit an authorized distributor letter shall result in the product(s) potentially offered to be considered grey market and shall not be considered technically acceptable. The capability statements received from this market research are for planning purposes only and will assist the Government in planning its acquisition strategy. This is strictly market research, and the Government will not entertain questions concerning this market research. The Government will not assume any costs incurred by the contractor in the preparation of responses. All responses shall be submitted in writing no later than November 23, 2026, at 5:00 PM EST to the attention of: Sign up to see this detail Please title the subject line for responses as: Performance Water Systems Service
Similar Contracts
Same NAICS industry code
More opportunities from Department Of Veterans Affairs → 246-NETWORK Contracting Office 6 (36C246)
Same awarding agency
Ready to Pursue This Opportunity?
Get AI-powered intelligence on this solicitation and the ones like it
Every page of the solicitation package shredded into a compliance breakdown
AI-powered matching based on your capabilities and past performance
Competitor and incumbent history on the requirement
Automated alerts on amendments, Q&A deadlines, and award
Join 750+ contractors already using CLEATUS