Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, September 16 at 2:00 PM EDT

Register Free →

This Combined Synopsis/Solicitation opportunity from Department Of Defense was posted on July 10, 2026. The submission period has ended. Browse the details below for market research, or find similar active opportunities.

LIFT STATION REDESIGN B20128

Closed
FA857126Q0079Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

Active Opportunities Like This One

NAICS: 237110
New
Seeking MBE/DBE/WBE Subcontractors and Suppliers for South Marsham Street Green Infrastructure Project (Romney, WV)
Solicitation # seeking-mbedbewbe-subcontractors-suppliers-south-marsham-street-green-infrastructure-project-romney
Harbel, Inc. is soliciting bids for a green-street retrofit project located on South Marsham Street between Gravel Lane and US Route 50 in Downtown Romney, West Virginia. The scope of work involves the installation of approximately 1,450 square feet of permeable pavement and eight vegetated stormwater management cells to treat roughly 1.7 acres of impervious surface within a 3.3-acre drainage area. The project requires comprehensive drainage, underdrain, inlet, pipe, and downspout work, along with limited curb, sidewalk, ADA, apron, crossing, and traffic-calming improvements to integrate the BMP corridor. Landscaping requirements include the planting of six native trees and approximately 345 native plants or approved equivalents, concluding with final stabilization, cleanup, and restoration. This solicitation specifically encourages participation from small business concerns, including minority, woman-owned, disadvantaged, HUBZone, and veteran-owned businesses, who may also form consortiums to handle larger bid items. Bids are due by 4:00 P.M. on September 17, 2026. Interested parties must submit a response indicating their intent to bid to the primary contact, Jonah Leith. The project falls under NAICS code 237110, focusing on professional civil engineering construction.
Harbel, Inc.

POSTED

about 6 hours ago

DEADLINE

in 5 days
NAICS: 237110
New
Inland Feeder/SBVMWD Foothill PS Intertie, Stage 1
Solicitation # inland-feedersbvmwd-foothill-ps-intertie-stage-1
The Inland Feeder/SBVMWD Foothill PS Intertie, Stage 1 project, located in Highland, California, is a comprehensive infrastructure initiative issued by the Metropolitan Water District of Southern California through James W. Fowler Co. The scope of work involves the furnishing and installation of approximately 2,150 linear feet of 54-inch to 66-inch diameter steel pipe and 200 linear feet of 144-inch diameter steel pipe. The project includes the installation of both contractor-furnished and Metropolitan-furnished valves ranging from 54 to 132 inches in diameter, as well as 54-inch and 145.5-inch diameter tie-ins and associated pipe fittings. Additional construction requirements include the delivery of four surge tanks, two valve vaults, an air compressor yard structure, and various drainage improvements. The technical scope extends to electrical upgrades, instrumentation and controls, piping systems, welding, disinfection, and surface restoration, alongside the excavation of cobbles and large boulders. This solicitation, posted on September 11, 2026, with a response deadline of September 29, 2026, is open to small businesses, including certified service-disabled veteran-owned, minority, and women-owned enterprises. The prime contractor, J.W. Fowler, is actively seeking subcontractor pricing and offering support to M/W/DBE firms regarding bonding, insurance, and equipment procurement to maximize participation.
James W. Fowler Co.

POSTED

about 6 hours ago

DEADLINE

in 17 days

AI Contract Overview

Show more

The Contractor is tasked with designing, supplying, and installing a redesigned lift station system for the Commodities Maintenance Group at Robins Air Force Base in Georgia, specifically for the safe transportation of hazardous liquid chemical waste such as acid and chrome waste. Each lift station must include two electric pumps constructed of CPVC or 316 Stainless Steel, with CPVC fittings no larger than two inches nominal size, capable of delivering 25 gallons per minute per pump under a 30-foot total dynamic head. The system must feature a polypropylene tank with a 50- to 75-gallon capacity in a single-tank containment configuration, and the entire unit must fit within dimensions of four feet long, three feet wide, and four feet high. The control panel enclosure must be stainless steel, powered by either 120V or 208V, and each pump must be equipped with disconnect switches, hands-off-auto controls, and automated level sensors to enable fully automated on/off operation. The Contractor is responsible for providing all tools, parts, materials, equipment, labor, transportation, startup, and training required for full system deployment and operation. The contract, identified as LIFT STATION REDESIGN B20128 under solicitation number FA857126Q0079, is a total small business set-aside under FAR 19.5 and falls under NAICS code 237110 for sewer and wastewater systems construction. Performance will occur at Warner Robins, Georgia, with a response deadline of July 17, 2026. The Contractor must deliver commercial drawings, status reports on EMS and EnMS training, a safety plan, and incident reporting documentation, as outlined in six CDRLs and WR-ALC Appendix C. No pricing, delivery schedule, inspection criteria, or contract value details are available in the provided documentation. The primary point of contact is Phillip Braswell, with Andrew Harth as secondary, and all communications must be directed through the Department of Defense office at Robins AFB. While the scope emphasizes full turnkey delivery and compliance with technical specifications, critical elements such as performance period, payment terms, acceptance standards, insurance, bonding, and safety compliance are not detailed in the available information.

General Info

Redesign and deliver lift stations at Robins AFB with pumps, tanks, controls, training, and startup.

Agency

Department Of Defense → FA8571 Maintenance Contracting Afsc PzimView Agency

NAICS

237110 - Water and Sewer Line and Related Structures ConstructionView NAICS

Place of Performance

Warner Robins, GA, 31098, USA

Set-Aside

SBA

Documents

(8)

Purchase Description for Lift Station Redesign B20128

PDFpurchase-description

CDRL A002 Status Report EMS Training

PDFcdrl

BAF 78451 Lift Station Redesign B20128 Appendix C Industrial Safety and Health Requirements

PDFsafety-and-health-requirements

CDRL A005 Accident/Incident Report for Lift Station Redesign

PDFcdrl

Solicitation FA857126Q0079 Lift Pump Station Redesign

PDFrfq

CDRL A003 Status Report - Energy Management System Training

PDFcdrl

CDRL A004 Contractor's Safety Plan for Lift Station Redesign

PDFcdrl

CDRL Amendment A001 - Commercial Drawings

PDFcdrl

AI Contract Breakdown

Uniform Contract Format

Sign up to view the full breakdown with detailed analysis of each section.

Timeline

1 update
PhaseClosed
Posted

Combined Synopsis

Amendment 1

Contract was updated

Response Deadline

Deadline has passed

Submission Closed

Find active opportunities like this

Start your free trial to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyDepartment Of Defense → FA8571 Maintenance Contracting Afsc Pzim
Contacts2 people available
OfficeROBINS AFB, GA, 31098-1672, USA
Organization / Agency
Department Of Defense → FA8571 Maintenance Contracting Afsc Pzim
View Agency Profile
Office AddressROBINS AFB, GA, 31098-1672, USA
Contacts
Phillip Braswell

Full Description

Show more

The Contractor shall provide all the tools, parts, materials, equipment, labor, transportation, startup, and training for a redesigned lift station to the Commodities Maintenance Group (CMXG) at Robins Air Force Base (AFB), Georgia. These lift stations will be used to transport liquid chemical waste that could present environmental danger (i.e. acid waste, chrome waste).


Each Lift Station shall have the following features:
• Two (2) electric pumps made of CPVC or 316 Stainless Steel. Pump fittings must be CPVC with a two (2) inch maximum nominal size. The pump flowrate should be 25 gallons per minute per pump. The pump must have a 30-foot total dynamic head.
• The tank material shall be polypropylene, with a volume of 50 to 75 gallons and a single tank containment style.
• The dimensions of the lift station shall be four (4) feet long, three (3) feet wide, and four (4) feet high.
• The control panel enclosure shall be made of stainless steel.
• The power supply shall be 120V or 208V.
• Each pump shall have disconnect switches, hands-off-auto, and level sensors for automation on/off pump operation.

More opportunities from Department Of Defense → FA8571 Maintenance Contracting Afsc Pzim

Same awarding agency

Find Active Opportunities Like This

Get AI-powered intelligence on the opportunities still open

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 650+ contractors already using CLEATUS