Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, October 28 at 2:00 PM ET

Register Free →

This Sources Sought opportunity from Department Of Defense was posted on March 27, 2026. The submission period has ended. Browse the details below for market research, or find similar active opportunities.

Lucky Peak Dam Water Quality Testing

Closed
W912EF26RSS20Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

Active Opportunities Like This One

NAICS: 541380
New
Federal
Granite Surface Plate Calibration and lapping - with Q&As
Solicitation # W519TC27QA007
Solicitation W519TC27QA007, issued by the Army Contracting Command - Rock Island, seeks an ISO 17025 accredited vendor to provide annual inspection, calibration, and lapping repair for granite surface plates at the Rock Island Arsenal Joint Manufacturing and Technology Center. The requirement is structured as a firm-fixed-price contract consisting of a base year from February 2, 2027, to February 1, 2028, with four subsequent option years, for a total potential duration of five years and six months. All work must be performed in accordance with ASME B89.3.7 and ANSI Z-540-1 standards, with calibrations traceable to NIST. The contract utilizes a hybrid pricing model where the annual inspection and calibration of all plates are firm-fixed-price lots, while lapping repairs are priced separately via an hourly labor rate and must be authorized by the Contracting Officer or COR. Estimated travel costs should be included in the firm-fixed pricing, though actual costs will be billed after service per Joint Travel Regulation rates. Deliverables include calibration stickers for each plate and a Service Acceptance Report submitted within three business days of completion. Offerors must submit their proposals by November 9, 2026, including a signed concurrence of the Scope of Work and documentation of their technical capabilities.
W6QK Acc-Ri

POSTED

about 11 hours ago

DEADLINE

in 13 days

General Info

NAICS

541380 - Testing Laboratories and Services

Place of Performance

Boise, ID, 83716, USA

Set-Aside

NONE

Documents

1

Performance Work Statement for Water Quality Testing at Lucky Peak Lake

PDF, High priority: read this firstperformance-work-statement
High

AI Contract Breakdown

Uniform Contract Format

Sign up to view the full breakdown with detailed analysis of each section.

Timeline

PhaseClosed
Posted

Sources Sought

Response Deadline

Deadline has passed

Submission Closed

Find active opportunities like this

Start your free trial to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyDepartment Of Defense → US Army Engineer District Walla Wal
Contacts2 people available
OfficeWALLA WALLA, WA, 99362-1876, USA
Office AddressWALLA WALLA, WA, 99362-1876, USA

Full Description

Show more

The U.S. Army Corps of Engineers, Walla Walla District, is seeking business sources for a service requirement entitled: "Lucky Peak Dam Water Quality Testing" for award of a base contract plus four option years. This is scheduled to be issued as a Firm Fixed Price Service Contract. The North American Industry Classification System (NAICS) code for this project is 541380 and the associated small business size standard is $19,000,000. 


This sources-sought announcement is a tool to identify businesses with the capability to accomplish the work. This is not a solicitation. Only those firms who respond to this announcement by submitting the following information will be used in determining whether to set aside this requirement. 



SUBMISSION REQUIREMENTS FOR RESPONSES TO THIS SOURCES SOUGHT SYNOPSIS:


(1) Your intent to submit a quote, bid, or proposal for this project when it is formally advertised.


(2) Name of firm with address, phone and point of contact.


(3) CAGE Code, UEI number or a copy of your System for Award Management (SAM) information.


(4) Provide a statement of your firm’s business size with regards to the NAICS code listed above. 


(5) Statement of Capability (SOC) stating your skills, experience, knowledge, and equipment required to perform the specified type of work.


(6) Please provide a statement if work is expected to be subcontracted for these services and identify the subcontractor(s), if applicable.


(7) Please provide feedback on the attached PWS. Does your firm have any comments or suggestions that you would like to share with the Government? The PWS is subject to change. 


---


Capabilities package/response submittal must be received no later than 11:00 AM Pacific Time on 06 April 2026.  Any information submitted is voluntary. Submit this information to Mary Seiner via email to contact@example.gov. 

More opportunities from Department Of Defense → US Army Engineer District Walla Wal

Same awarding agency

NAICS: 332812
New
Federal
Dworshak Skeleton Bay Draft Tube Bulkhead Rehabilitation
Solicitation # W912EF27QA0020001
The US Army Corps of Engineers, Walla Walla District, is soliciting bids for the rehabilitation of twelve draft tube bulkheads and associated seal keeper bars at Dworshak Dam. This total small business set-aside project, under solicitation W912EF27QA0020001, requires the contractor to provide all personnel, materials, and equipment necessary to transport the bulkheads from the dam to their repair facility and return them upon completion. The scope of work includes the removal of existing coatings, performing weld repairs, and applying new coatings. The project is divided into phases with specific pickup and return windows occurring between November 2026 and July 2027. All transportation must be coordinated with the Contracting Officer at least 15 calendar days in advance and conducted Monday through Thursday during specified hours. Technical requirements are stringent, requiring 100 percent inspection of all welds using Visual Testing and Magnetic Particle Testing in accordance with AWS D1./D1.M. Coating applications must meet specific dry film thickness standards, with a minimum average of 7.0 mils for the completed system. The contractor must provide a third-party certified coatings inspector and ensure all paint materials are certified by the CERL Lab. To be considered technically acceptable, bidders must submit specific pre-award documentation, including SSPC QP 3 or AISC Complex Coating Endorsements, paint product datasheets for System 5-E-Z, manufacturer warranties, and qualifications for both weld inspectors and welding operators. Government representatives will conduct internal inspections at the contractor's facility following the removal of existing coatings.
Metal Coating, Engraving (except Jewelry and Silverware), and Allied Services to Manufacturers

POSTED

about 11 hours ago

DEADLINE

in 3 days
View Details
NAICS: 811310
New
Federal
LLA Fish Pump - Motor Rewind
Solicitation # W912EF27QA006
Solicitation W912EF27QA006 is a combined synopsis and request for quotation issued by the US Army Engineer District Walla Walla for motor rewind and asbestos abatement services at the Lower Granite Dam in Pomeroy, Washington. The scope of work involves the rewinding, refurbishing, and addition of eight resistance temperature detectors to three polyphase AC squirrel cage induction motors used for fish pumps. This includes one Hitachi dual winding motor and two Ideal Electric single-winding motors. To ensure operational continuity, the project will be executed by rewinding one motor per year, with a total performance period extending through December 2029. The contract is a firm-fixed-price acquisition and is not set aside for small business concerns, although evaluation preferences are provided for HUBZone small businesses. Key technical requirements include the use of a minimum class F motor insulation system and strict adherence to core loss and hot spot specifications. Deliverables include the refurbished motors, final operation and maintenance manuals, and on-site commissioning support. The government has established a seven-business-day window for the acceptance or rejection of services following delivery. Liquidated damages are specified for delays, with daily rates increasing annually from FY28 through FY30. Offerors must comply with various federal regulations, including the Buy American and Balance of Payments Program, E-Verify personnel screening, and DFARS cybersecurity reporting standards.
Commercial and Industrial Machinery and Equipment (except Automotive and Electronic) Repair and Maintenance

POSTED

5 days ago

DEADLINE

in 27 days
View Details

Earlier notices in this NAICS code

Posted before this notice, open and closed

Find Active Opportunities Like This

Get AI-powered intelligence on the opportunities still open

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS