Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, October 28 at 2:00 PM ET

Register Free →

This Pre-Solicitation opportunity was posted on August 27, 2018. The submission period has ended. Browse the details below for market research, or find similar active opportunities.

Maintenance and Repair to Water Service Lines, Base Wide

Closed
SP4702-18-R-0533Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

Active Opportunities Like This One

NAICS: 237110
New
Federal
Z2NZ-- 658-23-108 Correct Stormwater Drainage
Solicitation # 36C24626B0031
Solicitation 36C24626B0031 is a firm-fixed-price sealed bid invitation for Project 658-23-108, which entails correcting stormwater drainage at the Salem VA Medical Center in Salem, Virginia. The project is a 100% set-aside for certified Service-Disabled Veteran-Owned Small Businesses (SDVOSB) under NAICS code 237110. The estimated magnitude of construction is between $10,000,000 and $20,000,000, with a performance period of 450 calendar days from the issuance of the Notice to Proceed. The scope of work includes general construction and utility work, specifically requiring the installation and 24/7 operation of a dewatering system and the use of flowable fill for backfilling in designated areas. The award will be made to an eligible SDVOSB that meets specific qualification criteria, including the completion of three projects of similar complexity and value within the last three years and a clean record regarding EPA and OSHA asbestos regulations. The prime contractor is required to perform at least 15% of the construction work. Bidders must be registered in the System for Award Management (SAM) and provide a bid guarantee of at least 20% of the bid price, capped at $3,000,000. Following several amendments, the final bid submission deadline is November 10, 2026, at 5:00 PM EST. Required submission documents include a signed SF 1442 offer page, an SF 24 bid bond, and a signed VAAR 852.219-75 Certificate of Compliance.
246-NETWORK Contracting Office 6 (36C246)

POSTED

about 3 hours ago

DEADLINE

in 21 days
NAICS: 237110
New
Morgans Branch Force Main and Pump Station Improvements
Solicitation # SRP-W-134-0290
The Morgans Branch Force Main and Pump Station Improvements project, solicitation number SRP-W-134-0290, is a construction contract for the City of Belmont in North Carolina with a project estimate of 16,690,000 dollars. The scope of work involves the construction of 16,435 linear feet of new 20-inch ductile iron force main and comprehensive upgrades to the Morgans Branch Pumping Station. Key infrastructure improvements include the installation of a new wet well, valve vault, and associated appurtenances, as well as the demolition of existing pumps and piping. The contractor is responsible for delivering a fully operational station featuring mechanical and electrical systems, including pumps, a generator, and odor control equipment, along with new gravity sewers and manholes. The contract is a small business set-aside and will be awarded to the responsible bidder submitting the lowest responsive bid. Bids must be submitted using the EJCDC C-410 form and include a bid bond, evidence of signing authority, and MWBE compliance documentation. Performance and payment bonds are required upon award. Project administration follows EJCDC standard general and supplementary conditions, with payments processed monthly via applications for payment reviewed by the Engineer. Final acceptance is contingent upon a substantial completion inspection, the resolution of a punch list, and a final inspection conducted by the Owner, Contractor, and Engineer.
Don Moorhead Construction, Inc.

POSTED

about 9 hours ago

DEADLINE

in 20 days

General Info

Agency

N/A

Contract Value

$1,704,480.39

NAICS

237110 - Water and Sewer Line and Related Structures Construction

Place of Performance

Not specified

Set-Aside

SBA

Award Issued Date

Documents

0

No documents available

Documents will appear here when they are available.

AI Contract Breakdown

Uniform Contract Format

No documents to break down

The breakdown needs solicitation documents. None were found from this contract's source.

Timeline

2 updates
PhaseClosed
Posted

Presolicitation

Notice updated

Response deadline changed from Aug 30, 2018 to Aug 29, 2018. The notice description changed.

Notice updated

Response deadline changed from Aug 29, 2018 to Aug 31, 2018. The notice description changed.

Response Deadline

Deadline has passed

Submission Closed

Find active opportunities like this

Start your free trial to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyN/A
Contacts1 person available
OfficeN/A
Organization / Agency
N/A
Office AddressN/A
Contacts
Karl J. HinchAcquisition Specialist

Full Description

Show more
1. Solicitation amendment 0001 is issued to provide questions (Q) submitted by vendors in response to the solicitation and answers (A) to those questions by the government to all potential vendors for this solicitation. 2. Questions and answers are as follows: (Q) Can an existing asphalt pavement detail be provided for repairs that need to be made to pavement at new tie-in locations? (A) See detail K/11 on drawing sheet 11 of 11 for information. (Q) Are there any restrictions related to paving contractors that can perform repairs on DFAS property? (A) No (Q) Service pipe sizes specified in the drawings (A) Changing pipe sizes from 6" steel to 2" or 3" copper piping (Q) Plan calls out to see detail L/11 on page 11, there is no detail L/11. (A) The detail has been deleted. (Q) Plan sheet 10 of 11 detail A/10 tells us to continue onto detail C on this sheet, there is no detail C. (A) Refer to revised Drawing 7-726, SP4702-18-R-0533 0001 Attachment # 2 (Q) Plan Sheet 9 of 11 Building 19 East Wall Chart shows the interior horizontal pipe length as 11'8'', and on Plan Sheet 10 of 11 the Chart shows the interior horizontal pipe lengths at 306 to be 13'2'' and the 2 at 308 to be 13'4'' and 12'4''. Can you confirm those dimensions due to the extent of additional work involved on the interior. (A) Refer to revised Drawing 7-726, SP4702-18-R-0533 0001 Attachment # 2 3. Attachments # 2 and # 3 of the basic solicitation are replaced with Attachments # 2 and # 3 of solicitation amendment 0001. 4. The solicitation closing date is revised to August 31, 2018 at 3:00 pm est. 5. All terms and conditions for this solicitation remain unchanged.

Find Active Opportunities Like This

Get AI-powered intelligence on the opportunities still open

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS