Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, September 2 at 2:00 PM EDT

Register Free →

NSAP B3 Renovation

Active
Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

General Info

Agency

Department Of The Navy → Navfac Mid-AtlanticView Agency

NAICS

N/A

Place of Performance

ML: PENNS, USA

Set-Aside

8A

Documents

(0)

No documents available

AI Contract Breakdown

Uniform Contract Format

No contract breakdown available.

Cannot generate Contract Breakdown because no documents were found from this contract's source.

Timeline

Posted

forecast

Ready to pursue this opportunity?

Start your free trial to track this contract, build proposals with AI assistance, and manage your pipeline.

Organization & Contact Information

Show more
AgencyDepartment Of The Navy → Navfac Mid-Atlantic
ContactsNo contacts available
OfficeN/A
Organization / Agency
Department Of The Navy → Navfac Mid-Atlantic
View Agency Profile
Office AddressN/A
ContactsNo contact information available

Full Description

Show more
This TF-1 is for submitting a work induction request for AE design and construction related to the interior renovation of Building 3 in its entirety. The construction will proceed by bay by bay, starting with A bay. Upon completion of A bay, work will then move to B bay, followed by C bay and finally D bay. GTGXMJ The scope of work for the AE design of the entire building 3 shall include, but is not limited to, the following: - Architectural, Mechanical, Electrical, Plumbing, Fire Protection and interior design etc. - The exterior walls of Building 3 will remain. However, all interior furred walls, insulation, and all exterior glazing - including windows, storefront systems, and doors with glazing are to be redesigned, removed and replaced. - Restrooms have been relocated to be centralized near the oasis areas. Finishes, plumbing fixtures, toilet partitions in restrooms are to be redesigned. - Existing Life safety egress paths and fire protection systems must be evaluated during the design phase. - Roofing repairs and patching due to rooftop HVAC equipment replacements must be evaluated in the design phase. - In the design phase, it is essential to evaluate whether the existing HVAC units can adequately handle the expected load without compromising performance. The assessment shall include a detailed load calculation, airflow analysis and an evaluation of equipment capacity to ensure efficient operation and occupant comfort. - Interior lighting and mechanical systems will undergo further evaluation in the design phase to improve climate control and meet indoor lighting requirements. - Storefront systems must be evaluated to meet UFC 1-200-02 High Performance and Sustainable Building Requirements and International Energy Conservation Code (IECC) requirements. - Interior spaces will be designed to ensure acoustic ... NOTE: description has been truncated, please see Project Note for full description.