Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, September 2 at 2:00 PM EDT

Register Free →

NSN D-29 INTERIOR SPACE RENOVATION (ROC) & TRAILERS INSTALLATION

Active
Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

General Info

Agency

Department Of The Navy → Navfac Mid-AtlanticView Agency

NAICS

N/A

Place of Performance

ML: NORFOLK, USA

Set-Aside

NONE

Documents

(0)

No documents available

AI Contract Breakdown

Uniform Contract Format

No contract breakdown available.

Cannot generate Contract Breakdown because no documents were found from this contract's source.

Timeline

Posted

forecast

Ready to pursue this opportunity?

Start your free trial to track this contract, build proposals with AI assistance, and manage your pipeline.

Organization & Contact Information

Show more
AgencyDepartment Of The Navy → Navfac Mid-Atlantic
ContactsNo contacts available
OfficeN/A
Organization / Agency
Department Of The Navy → Navfac Mid-Atlantic
View Agency Profile
Office AddressN/A
ContactsNo contact information available

Full Description

Show more
Customer Funded Interior Space Renovation in support standing up a Readiness Operation Center (ROC) in space B06. Request two temporary Office trailers to support the move of 32 personnel out space to be renovated, disassemble and remove all furniture in space to be renovated. A conceptual drawing is attach for finish layout of the proposed interior space renovation of the ROC. Currently this command is conducting ROC operations out of a large and small conference rooms. This renovated space will provide command and control of operation in a single location. FY24 3rd Qtr. Currently command and control of the ROC will continue haphazardly if the identified space renovation is delayed or not completed by 3rd Qtr. FY24. Interior space renovation in area B room B06 (1,945SF), B07 (office #1 103SF), B08 (Roc Director 158SF), B09 (office #2 107SF), B10 (office #3 107SF). - Remove system furniture in room B06 and prepare DRMO, furniture to remain in rooms B07, B08, B09, B10 - Wall covering Patch and Paint room B06, B07 (office #1), B08 (ROC Director) 158SF, B09 (office #2) 107SF, B10 (office #3) 107SF. - Floor covering (carpet square tiles) to remain - Replace all ceiling tiles in the entire space - Repair any ceiling lighting not working in the entire space - Request wall receptacles to support the 70–75-inch TV monitor location (northeast corner wall), the six-wall mounted video wall screen monitors (south wall), the two secure VTC monitors (south wall), receptacles for the secure VTC controls panel - Request new furniture and arranged accord to ... NOTE: description has been truncated, please see Project Note for full description.