Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, September 2 at 2:00 PM EDT

Register Free →

Purchase and install of Hussy Seating Maxim wall-attached telescopic bleacher system and removal of existing bleachers

Active
FA813626Q0011Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

General Info

Agency

Department Of Defense → FA8136 Afsc PziobView Agency

NAICS

337127 - Institutional Furniture ManufacturingView NAICS

Place of Performance

0, OK, 73145, USA

Set-Aside

SBA

Documents

(0)

No documents available

AI Contract Breakdown

Uniform Contract Format

No contract breakdown available.

Cannot generate Contract Breakdown because no documents were found from this contract's source.

Timeline

PhaseSolicitation
Posted

Solicitation

Response Deadline

Submission deadline

Response Deadline

Ready to pursue this opportunity?

Start your free trial to track this contract, build proposals with AI assistance, and manage your pipeline.

Organization & Contact Information

Show more
AgencyDepartment Of Defense → FA8136 Afsc Pziob
Contacts2 people available
OfficeTINKER AFB, OK, 73145-9125, USA
Organization / Agency
Department Of Defense → FA8136 Afsc Pziob
View Agency Profile
Office AddressTINKER AFB, OK, 73145-9125, USA

Full Description

Show more

The response deadline for this solicitation is 14 September 2026 at 2:00 PM CST. A site visit will be offered (optional) on 1 September 2026 so vendors can ensure accurate measurements. Questions are due 3 September 2026 at 2:00 PM CST. All interested parties should contact Lauren Rodgers, lauren.rodgers.5@us.af.mil and Contracting Officer MSgt Kristoforus Wenas, kristoforus.wenas.1@us.af.mil to schedule site visit. 


This RFQ is being issued on SAM.gov as a small business set aside. 



Purchase is required to satisfy Youth Center seating-
• The current bleachers were installed 25 years ago and have reached the end of their service life. Replacement is necessary to ensure continued safety, reliability for all Youth Center spectators.

The vendor will provide MAXAM telescopic bleachers manufactured by Hussey Seating Company that will perform full installation of the system. The scope of work includes demolition and removal of the existing bleacher system. The new bleachers will be attached to the wall and designed to retract to extend maximum available floor space.

System Classification
• Brand & Model: Hussey Seating Company MAXAM Telescopic Series (or approved equivalent meeting identical dimensional and safety tolerances).
• Design: Wall-attached, manually operated, multi-tier retractable spectator seating system designed specifically for indoor gymnasium environments.
Physical Dimensions
• Installed Length: Approximately 45 feet (45' total continuous length).
• Fully Deployed Depth: Maximum 9 feet, 1 inch (9' 1") from the mounting wall.
• Row Quantity & Spacing: 5 rows (tiers) of seating with a standard 22-inch to 24-inch row spacing to ensure adequate legroom and egress.
Material & Construction
• Understructure Frame: Heavy-duty, high-tensile structural steel shapes forming a rigid, self-supporting understructure, finished with a corrosion-resistant black powder coat.
• Decks & Under-decking: Minimum 5/8-inch exterior-grade plywood panels with a durable, non-slip textured poly-wear surface overlay.
• Seating Type: CourtSide collection contoured HDPE (High-Density Polyethylene) seats, 10-inch (254 mm) depth, featuring an anatomical curved design with a front "waterfall" edge to alleviate thigh pressure.
Demolition & Site Prep
• Complete demolition and removal of existing 25-year-old bleachers with zero damage to surrounding walls, gym floor, or utility lines.
• 100% damage-free. Any accidental damage must be repaired/restored to original condition at contractor expense within 5 business days.
• 100% Inspection by COR and Youth Center Facility Manager.
Operational Method
• Operation: Manual operation utilizing a high-efficiency pull-handle/draw-bar system.
• Tracking: Must feature self-supporting first-row wheels and structural guide tracks to allow smooth, single-operator extension and retraction without binding.
• Operational Training: Provide comprehensive, on-site operational and safety training to at least five (5) designated Youth Center staff members.
Accessibility Compliance (ADA)
• Wheelchair Spaces: Minimum of four (4) integrated, ADA-compliant wheelchair seating locations recovered within the footprint.
• Companion Seating: Adjacent companion seating structurally integrated as required by the Americans with Disabilities Act (ADA) and the International Building Code (IBC).
Safety & Egress Features
• Aisle Handrails: Center-aisle, self-storing, or removable structural steel handrails with round profiles, finished in high-visibility safety colors.
• End Rails (Guardrails): Full-height steel guardrails at both open ends of the bleacher system, meeting a minimum lateral load requirement of 50 lbs/ft at the top rail.
• Locking Mechanisms: Automatic mechanical tier locks that securely lock each row in the fully extended position to prevent accidental retraction during occupancy.
Structural Load Standards
• Compliance: Must conform to IBC (International Building Code) and ICC 300 (Standard for Bleachers, Folding and Telescopic Seating, and Grandstands) load ratings.
• Active Live Load: Minimum 120 lbs/sq ft active horizontal framework capacity.
• Sway Load: 24 lbs/linear ft parallel to seats; 10 lbs/linear ft perpendicular to seats.
Execution & Safety Certification
• Installation: Must be executed by a factory-certified installer.
• Testing: Installer must conduct a formal structural and operational safety test prior to government acceptance.


***Additional requirements listed in attached SON. 


Delivery/Services Required: 


The contractor shall be responsible for all freight and shipping costs to provide FOB Destination inside delivery to Tinker AFB, Oklahoma 73145. Delivery is required 60 days After Receipt of Order (ARO). 


Eligibility:


The applicable NAICS Code for this requirement is 337127. The Product/Service Code (PSC) for this effort is 7195. This NAICS is the only applicable NAICS for this effort. To be considered for this award, contractor must have this NAICS on their profile. If it is not on contractor profile, request it to be added. 


In order to make a determination for a amall business set-aside, two or more qualified and capable small businesses must submit responses that demonstrate their qualifications and ability to perform in accordance with the Limitations on Subcontracting clause (FAR 52.219-14). 


Producuct Service Code: 7195


Pricing Arrangement: Firm Fixed Price

Similar Contracts

Same NAICS industry code

NAICS: 337127
New
Federal
Area 62 Medical/Dental Clinic Replacement IO Project
Solicitation # W9127S26QA044
This solicitation, numbered W9127S26QA044, seeks quotations for the Area 62 Medical/Dental Clinic Replacement Project under a Service-Disabled Veteran-Owned Small Business Set-Aside, with the NAICS code 337127 for Institutional Furniture Manufacturing and a size standard of 500 employees. All offers must be submitted by 10:00 a.m. Central Time on July 27, 2026, with a mandatory site visit scheduled for July 9, 2026, at 1:00 p.m. Pacific Time. The requirement is subject to the Nonmanufacturer Rule, mandating that at least 50 percent of the total contract value consist of end items produced or processed by a domestic small manufacturer or processor; contractors must promptly notify the Contracting Officer of any items lacking a qualified small manufacturer to avoid waiver delays or proposal rejection. The Buy American Act applies, and adherence to the Nonmanufacturer Rule and Buy American provisions is strictly required to prevent protests, delays, or cancellation. The contract will be awarded under the Federal Acquisition Regulation’s commercial item framework, incorporating clauses such as 52.212-4 and its addendum, along with evaluation instructions under 52.212-2. The awardee will be subject to performance evaluations under the Contractor Performance Assessment Reporting System. The solicitation is issued by the Department of Defense, Office of the Army Corps of Engineers in Little Rock, Arkansas, with performance expected in the 92055 zip code area, and all inquiries should be directed to Timothy Pighee.
W076 Endist Little Rock

POSTED

1 day ago

DEADLINE

in 4 days
View Details